ABAP Select data from SAP table P2QA_SR_QA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P2QA_SR_QA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P2QA_SR_QA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P2QA_SR_QA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P2QA_SR_QA TYPE STANDARD TABLE OF P2QA_SR_QA,
      WA_P2QA_SR_QA TYPE P2QA_SR_QA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P2QA_SR_QA> TYPE P2QA_SR_QA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P2QA_SR_QA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P2QA_SR_QA
  INTO TABLE IT_P2QA_SR_QA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P2QA_SR_QA
*  INTO TABLE @DATA(IT_P2QA_SR_QA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P2QA_SR_QA INDEX 1 INTO DATA(WA_P2QA_SR_QA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P2QA_SR_QA ASSIGNING <P2QA_SR_QA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P2QA_SR_QA>-MANDT = 1.
<P2QA_SR_QA>-DCT_PERNR = 1.
<P2QA_SR_QA>-DCT_SEQNR = 1.
<P2QA_SR_QA>-DCT_ROWID = 1.
<P2QA_SR_QA>-RPTYP = 1.
ENDLOOP.

LOOP AT IT_P2QA_SR_QA INTO WA_P2QA_SR_QA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P2QA_SR_QA-OBJPS, sy-vline,
WA_P2QA_SR_QA-BEGDA, sy-vline,
WA_P2QA_SR_QA-ENDDA, sy-vline,
WA_P2QA_SR_QA-RPMTH, sy-vline,
WA_P2QA_SR_QA-RPAYR, sy-vline,
WA_P2QA_SR_QA-PCHSD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P2QA_SR_QA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P2QA_SR_QA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P2QA_SR_QA INTO WA_P2QA_SR_QA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field RPAYR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_P2QA_SR_QA-RPAYR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P2QA_SR_QA-RPAYR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P2QA_SR_QA_STR,
MANDT TYPE STRING,
DCT_PERNR TYPE STRING,
DCT_SEQNR TYPE STRING,
DCT_ROWID TYPE STRING,
RPTYP TYPE STRING,
OBJPS TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
RPMTH TYPE STRING,
RPAYR TYPE STRING,
PCHSD TYPE STRING,
CRAMT TYPE STRING,
TRAMT TYPE STRING,
TDAMT TYPE STRING,
ITAMT TYPE STRING,
LGART TYPE STRING,
FRAMT TYPE STRING,
WAERS TYPE STRING,END OF T_EKKO_STR. DATA: WA_P2QA_SR_QA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P2QA_SR_QA_STR-MANDT sy-vline
WA_P2QA_SR_QA_STR-DCT_PERNR sy-vline
WA_P2QA_SR_QA_STR-DCT_SEQNR sy-vline
WA_P2QA_SR_QA_STR-DCT_ROWID sy-vline
WA_P2QA_SR_QA_STR-RPTYP sy-vline
WA_P2QA_SR_QA_STR-OBJPS sy-vline
WA_P2QA_SR_QA_STR-BEGDA sy-vline
WA_P2QA_SR_QA_STR-ENDDA sy-vline
WA_P2QA_SR_QA_STR-RPMTH sy-vline
WA_P2QA_SR_QA_STR-RPAYR sy-vline
WA_P2QA_SR_QA_STR-PCHSD sy-vline
WA_P2QA_SR_QA_STR-CRAMT sy-vline
WA_P2QA_SR_QA_STR-TRAMT sy-vline
WA_P2QA_SR_QA_STR-TDAMT sy-vline
WA_P2QA_SR_QA_STR-ITAMT sy-vline
WA_P2QA_SR_QA_STR-LGART sy-vline
WA_P2QA_SR_QA_STR-FRAMT sy-vline
WA_P2QA_SR_QA_STR-WAERS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.