ABAP Select data from SAP table P2KZ_FUP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P2KZ_FUP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P2KZ_FUP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P2KZ_FUP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P2KZ_FUP TYPE STANDARD TABLE OF P2KZ_FUP,
      WA_P2KZ_FUP TYPE P2KZ_FUP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P2KZ_FUP> TYPE P2KZ_FUP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P2KZ_FUP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P2KZ_FUP
  INTO TABLE IT_P2KZ_FUP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P2KZ_FUP
*  INTO TABLE @DATA(IT_P2KZ_FUP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P2KZ_FUP INDEX 1 INTO DATA(WA_P2KZ_FUP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P2KZ_FUP ASSIGNING <P2KZ_FUP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P2KZ_FUP>-MANDT = 1.
<P2KZ_FUP>-DCT_PERNR = 1.
<P2KZ_FUP>-DCT_SEQNR = 1.
<P2KZ_FUP>-DCT_ROWID = 1.
<P2KZ_FUP>-INPER = 1.
ENDLOOP.

LOOP AT IT_P2KZ_FUP INTO WA_P2KZ_FUP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P2KZ_FUP-BEGDA, sy-vline,
WA_P2KZ_FUP-ENDDA, sy-vline,
WA_P2KZ_FUP-ABART, sy-vline,
WA_P2KZ_FUP-LGART, sy-vline,
WA_P2KZ_FUP-APZNR, sy-vline,
WA_P2KZ_FUP-CNTR1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P2KZ_FUP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P2KZ_FUP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P2KZ_FUP INTO WA_P2KZ_FUP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P2KZ_FUP_STR,
MANDT TYPE STRING,
DCT_PERNR TYPE STRING,
DCT_SEQNR TYPE STRING,
DCT_ROWID TYPE STRING,
INPER TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
ABART TYPE STRING,
LGART TYPE STRING,
APZNR TYPE STRING,
CNTR1 TYPE STRING,
CNTR2 TYPE STRING,
CNTR3 TYPE STRING,
C1ZNR TYPE STRING,
ABZNR TYPE STRING,
V0TYP TYPE STRING,
V0ZNR TYPE STRING,
BETPE TYPE STRING,
ANZHL TYPE STRING,
BETRG TYPE STRING,
RTE_CURR TYPE STRING,
AMT_CURR TYPE STRING,
DOCNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_P2KZ_FUP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P2KZ_FUP_STR-MANDT sy-vline
WA_P2KZ_FUP_STR-DCT_PERNR sy-vline
WA_P2KZ_FUP_STR-DCT_SEQNR sy-vline
WA_P2KZ_FUP_STR-DCT_ROWID sy-vline
WA_P2KZ_FUP_STR-INPER sy-vline
WA_P2KZ_FUP_STR-BEGDA sy-vline
WA_P2KZ_FUP_STR-ENDDA sy-vline
WA_P2KZ_FUP_STR-ABART sy-vline
WA_P2KZ_FUP_STR-LGART sy-vline
WA_P2KZ_FUP_STR-APZNR sy-vline
WA_P2KZ_FUP_STR-CNTR1 sy-vline
WA_P2KZ_FUP_STR-CNTR2 sy-vline
WA_P2KZ_FUP_STR-CNTR3 sy-vline
WA_P2KZ_FUP_STR-C1ZNR sy-vline
WA_P2KZ_FUP_STR-ABZNR sy-vline
WA_P2KZ_FUP_STR-V0TYP sy-vline
WA_P2KZ_FUP_STR-V0ZNR sy-vline
WA_P2KZ_FUP_STR-BETPE sy-vline
WA_P2KZ_FUP_STR-ANZHL sy-vline
WA_P2KZ_FUP_STR-BETRG sy-vline
WA_P2KZ_FUP_STR-RTE_CURR sy-vline
WA_P2KZ_FUP_STR-AMT_CURR sy-vline
WA_P2KZ_FUP_STR-DOCNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.