ABAP Select data from SAP table P2HK_SV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P2HK_SV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P2HK_SV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P2HK_SV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P2HK_SV TYPE STANDARD TABLE OF P2HK_SV,
      WA_P2HK_SV TYPE P2HK_SV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P2HK_SV> TYPE P2HK_SV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P2HK_SV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P2HK_SV
  INTO TABLE IT_P2HK_SV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P2HK_SV
*  INTO TABLE @DATA(IT_P2HK_SV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P2HK_SV INDEX 1 INTO DATA(WA_P2HK_SV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P2HK_SV ASSIGNING <P2HK_SV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P2HK_SV>-MANDT = 1.
<P2HK_SV>-DCT_PERNR = 1.
<P2HK_SV>-DCT_SEQNR = 1.
<P2HK_SV>-DCT_ROWID = 1.
<P2HK_SV>-CNTR1 = 1.
ENDLOOP.

LOOP AT IT_P2HK_SV INTO WA_P2HK_SV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P2HK_SV-ENDDA, sy-vline,
WA_P2HK_SV-BEGDA, sy-vline,
WA_P2HK_SV-CONTP, sy-vline,
WA_P2HK_SV-EEMPR, sy-vline,
WA_P2HK_SV-EENPR, sy-vline,
WA_P2HK_SV-ERMPR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P2HK_SV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P2HK_SV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P2HK_SV INTO WA_P2HK_SV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P2HK_SV_STR,
MANDT TYPE STRING,
DCT_PERNR TYPE STRING,
DCT_SEQNR TYPE STRING,
DCT_ROWID TYPE STRING,
CNTR1 TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
CONTP TYPE STRING,
EEMPR TYPE STRING,
EENPR TYPE STRING,
ERMPR TYPE STRING,
ERNPR TYPE STRING,
INCRG TYPE STRING,
OPCON TYPE STRING,
EEFPC TYPE STRING,
EEEPC TYPE STRING,
EEFAM TYPE STRING,
WAEFA TYPE STRING,
EEEAM TYPE STRING,
WAEEA TYPE STRING,
ERFPC TYPE STRING,
EREPC TYPE STRING,
ERFAM TYPE STRING,
WARFA TYPE STRING,
EREAM TYPE STRING,
WAREA TYPE STRING,
EEMWT TYPE STRING,
EENWT TYPE STRING,
ERMWT TYPE STRING,
ERNWT TYPE STRING,
SALWT TYPE STRING,
SCALC TYPE STRING,
CUMTY TYPE STRING,
MNINC TYPE STRING,
MNCRY TYPE STRING,
MXINC TYPE STRING,
MXCRY TYPE STRING,
MNAGE TYPE STRING,
MXAGE TYPE STRING,
EEACM TYPE STRING,
ERACM TYPE STRING,
EEACC TYPE STRING,
ERACC TYPE STRING,
SCRYY TYPE STRING,
SCRMM TYPE STRING,
SCRDD TYPE STRING,
EEAGE TYPE STRING,
PRVER TYPE STRING,
PLSTA TYPE STRING,
CUMCM TYPE STRING,
PRECB TYPE STRING,
CMTHD TYPE STRING,
MNIND TYPE STRING,
MNDCR TYPE STRING,
MXIND TYPE STRING,
MXDCR TYPE STRING,
PRVCA TYPE STRING,
PREMP TYPE STRING,
VCAMA TYPE STRING,END OF T_EKKO_STR. DATA: WA_P2HK_SV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P2HK_SV_STR-MANDT sy-vline
WA_P2HK_SV_STR-DCT_PERNR sy-vline
WA_P2HK_SV_STR-DCT_SEQNR sy-vline
WA_P2HK_SV_STR-DCT_ROWID sy-vline
WA_P2HK_SV_STR-CNTR1 sy-vline
WA_P2HK_SV_STR-ENDDA sy-vline
WA_P2HK_SV_STR-BEGDA sy-vline
WA_P2HK_SV_STR-CONTP sy-vline
WA_P2HK_SV_STR-EEMPR sy-vline
WA_P2HK_SV_STR-EENPR sy-vline
WA_P2HK_SV_STR-ERMPR sy-vline
WA_P2HK_SV_STR-ERNPR sy-vline
WA_P2HK_SV_STR-INCRG sy-vline
WA_P2HK_SV_STR-OPCON sy-vline
WA_P2HK_SV_STR-EEFPC sy-vline
WA_P2HK_SV_STR-EEEPC sy-vline
WA_P2HK_SV_STR-EEFAM sy-vline
WA_P2HK_SV_STR-WAEFA sy-vline
WA_P2HK_SV_STR-EEEAM sy-vline
WA_P2HK_SV_STR-WAEEA sy-vline
WA_P2HK_SV_STR-ERFPC sy-vline
WA_P2HK_SV_STR-EREPC sy-vline
WA_P2HK_SV_STR-ERFAM sy-vline
WA_P2HK_SV_STR-WARFA sy-vline
WA_P2HK_SV_STR-EREAM sy-vline
WA_P2HK_SV_STR-WAREA sy-vline
WA_P2HK_SV_STR-EEMWT sy-vline
WA_P2HK_SV_STR-EENWT sy-vline
WA_P2HK_SV_STR-ERMWT sy-vline
WA_P2HK_SV_STR-ERNWT sy-vline
WA_P2HK_SV_STR-SALWT sy-vline
WA_P2HK_SV_STR-SCALC sy-vline
WA_P2HK_SV_STR-CUMTY sy-vline
WA_P2HK_SV_STR-MNINC sy-vline
WA_P2HK_SV_STR-MNCRY sy-vline
WA_P2HK_SV_STR-MXINC sy-vline
WA_P2HK_SV_STR-MXCRY sy-vline
WA_P2HK_SV_STR-MNAGE sy-vline
WA_P2HK_SV_STR-MXAGE sy-vline
WA_P2HK_SV_STR-EEACM sy-vline
WA_P2HK_SV_STR-ERACM sy-vline
WA_P2HK_SV_STR-EEACC sy-vline
WA_P2HK_SV_STR-ERACC sy-vline
WA_P2HK_SV_STR-SCRYY sy-vline
WA_P2HK_SV_STR-SCRMM sy-vline
WA_P2HK_SV_STR-SCRDD sy-vline
WA_P2HK_SV_STR-EEAGE sy-vline
WA_P2HK_SV_STR-PRVER sy-vline
WA_P2HK_SV_STR-PLSTA sy-vline
WA_P2HK_SV_STR-CUMCM sy-vline
WA_P2HK_SV_STR-PRECB sy-vline
WA_P2HK_SV_STR-CMTHD sy-vline
WA_P2HK_SV_STR-MNIND sy-vline
WA_P2HK_SV_STR-MNDCR sy-vline
WA_P2HK_SV_STR-MXIND sy-vline
WA_P2HK_SV_STR-MXDCR sy-vline
WA_P2HK_SV_STR-PRVCA sy-vline
WA_P2HK_SV_STR-PREMP sy-vline
WA_P2HK_SV_STR-VCAMA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.