ABAP Select data from SAP table P22_PC202_ALV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P22_PC202_ALV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P22_PC202_ALV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P22_PC202_ALV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P22_PC202_ALV TYPE STANDARD TABLE OF P22_PC202_ALV,
      WA_P22_PC202_ALV TYPE P22_PC202_ALV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P22_PC202_ALV> TYPE P22_PC202_ALV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P22_PC202_ALV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P22_PC202_ALV
  INTO TABLE IT_P22_PC202_ALV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P22_PC202_ALV
*  INTO TABLE @DATA(IT_P22_PC202_ALV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P22_PC202_ALV INDEX 1 INTO DATA(WA_P22_PC202_ALV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P22_PC202_ALV ASSIGNING <P22_PC202_ALV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P22_PC202_ALV>-MOLGA = 1.
<P22_PC202_ALV>-ABKRS = 1.
<P22_PC202_ALV>-JUPER = 1.
<P22_PC202_ALV>-WAERS = 1.
<P22_PC202_ALV>-GROSS = 1.
ENDLOOP.

LOOP AT IT_P22_PC202_ALV INTO WA_P22_PC202_ALV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P22_PC202_ALV-GDATE, sy-vline,
WA_P22_PC202_ALV-NET, sy-vline,
WA_P22_PC202_ALV-NDATE, sy-vline,
WA_P22_PC202_ALV-FPBEG, sy-vline,
WA_P22_PC202_ALV-FPEND, sy-vline,
WA_P22_PC202_ALV-IPERM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P22_PC202_ALV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P22_PC202_ALV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P22_PC202_ALV INTO WA_P22_PC202_ALV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P22_PC202_ALV_STR,
MOLGA TYPE STRING,
ABKRS TYPE STRING,
JUPER TYPE STRING,
WAERS TYPE STRING,
GROSS TYPE STRING,
GDATE TYPE STRING,
NET TYPE STRING,
NDATE TYPE STRING,
FPBEG TYPE STRING,
FPEND TYPE STRING,
IPERM TYPE STRING,
INPER TYPE STRING,
BONDT TYPE STRING,
PAYTY TYPE STRING,
PAYID TYPE STRING,
VOID TYPE STRING,
VOIDD TYPE STRING,
VOIDT TYPE STRING,
VOIDR TYPE STRING,
PAYDT TYPE STRING,
FPPER TYPE STRING,
PERMO TYPE STRING,
INPTY TYPE STRING,
INPID TYPE STRING,
IPEND TYPE STRING,
RUNDT TYPE STRING,
RUNTM TYPE STRING,
IABKRS TYPE STRING,
OCRSN TYPE STRING,
INOCR TYPE STRING,
OCCAT TYPE STRING,
INOCC TYPE STRING,
REVERSAL TYPE STRING,
OUTOFSEQ TYPE STRING,
OOSDATE TYPE STRING,
PERSON TYPE STRING,
PERSDATA TYPE STRING,
BRACKET TYPE STRING,
FPPER_MODIF TYPE STRING,
INPER_MODIF TYPE STRING,
INVALID TYPE STRING,END OF T_EKKO_STR. DATA: WA_P22_PC202_ALV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P22_PC202_ALV_STR-MOLGA sy-vline
WA_P22_PC202_ALV_STR-ABKRS sy-vline
WA_P22_PC202_ALV_STR-JUPER sy-vline
WA_P22_PC202_ALV_STR-WAERS sy-vline
WA_P22_PC202_ALV_STR-GROSS sy-vline
WA_P22_PC202_ALV_STR-GDATE sy-vline
WA_P22_PC202_ALV_STR-NET sy-vline
WA_P22_PC202_ALV_STR-NDATE sy-vline
WA_P22_PC202_ALV_STR-FPBEG sy-vline
WA_P22_PC202_ALV_STR-FPEND sy-vline
WA_P22_PC202_ALV_STR-IPERM sy-vline
WA_P22_PC202_ALV_STR-INPER sy-vline
WA_P22_PC202_ALV_STR-BONDT sy-vline
WA_P22_PC202_ALV_STR-PAYTY sy-vline
WA_P22_PC202_ALV_STR-PAYID sy-vline
WA_P22_PC202_ALV_STR-VOID sy-vline
WA_P22_PC202_ALV_STR-VOIDD sy-vline
WA_P22_PC202_ALV_STR-VOIDT sy-vline
WA_P22_PC202_ALV_STR-VOIDR sy-vline
WA_P22_PC202_ALV_STR-PAYDT sy-vline
WA_P22_PC202_ALV_STR-FPPER sy-vline
WA_P22_PC202_ALV_STR-PERMO sy-vline
WA_P22_PC202_ALV_STR-INPTY sy-vline
WA_P22_PC202_ALV_STR-INPID sy-vline
WA_P22_PC202_ALV_STR-IPEND sy-vline
WA_P22_PC202_ALV_STR-RUNDT sy-vline
WA_P22_PC202_ALV_STR-RUNTM sy-vline
WA_P22_PC202_ALV_STR-IABKRS sy-vline
WA_P22_PC202_ALV_STR-OCRSN sy-vline
WA_P22_PC202_ALV_STR-INOCR sy-vline
WA_P22_PC202_ALV_STR-OCCAT sy-vline
WA_P22_PC202_ALV_STR-INOCC sy-vline
WA_P22_PC202_ALV_STR-REVERSAL sy-vline
WA_P22_PC202_ALV_STR-OUTOFSEQ sy-vline
WA_P22_PC202_ALV_STR-OOSDATE sy-vline
WA_P22_PC202_ALV_STR-PERSON sy-vline
WA_P22_PC202_ALV_STR-PERSDATA sy-vline
WA_P22_PC202_ALV_STR-BRACKET sy-vline
WA_P22_PC202_ALV_STR-FPPER_MODIF sy-vline
WA_P22_PC202_ALV_STR-INPER_MODIF sy-vline
WA_P22_PC202_ALV_STR-INVALID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.