ABAP Select data from SAP table P20_RMB_EE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P20_RMB_EE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P20_RMB_EE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P20_RMB_EE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P20_RMB_EE TYPE STANDARD TABLE OF P20_RMB_EE,
      WA_P20_RMB_EE TYPE P20_RMB_EE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P20_RMB_EE> TYPE P20_RMB_EE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P20_RMB_EE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P20_RMB_EE
  INTO TABLE IT_P20_RMB_EE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P20_RMB_EE
*  INTO TABLE @DATA(IT_P20_RMB_EE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P20_RMB_EE INDEX 1 INTO DATA(WA_P20_RMB_EE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P20_RMB_EE ASSIGNING <P20_RMB_EE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P20_RMB_EE>-PERNR = 1.
<P20_RMB_EE>-FDNUM = 1.
<P20_RMB_EE>-ENAVN = 1.
<P20_RMB_EE>-FNAVN = 1.
<P20_RMB_EE>-STRAS = 1.
ENDLOOP.

LOOP AT IT_P20_RMB_EE INTO WA_P20_RMB_EE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P20_RMB_EE-PSTNR, sy-vline,
WA_P20_RMB_EE-BOKOM, sy-vline,
WA_P20_RMB_EE-ADRS, sy-vline,
WA_P20_RMB_EE-ANRED, sy-vline,
WA_P20_RMB_EE-NAME1, sy-vline,
WA_P20_RMB_EE-NAME2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P20_RMB_EE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P20_RMB_EE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P20_RMB_EE INTO WA_P20_RMB_EE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_P20_RMB_EE-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P20_RMB_EE-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_P20_RMB_EE-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P20_RMB_EE-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P20_RMB_EE_STR,
PERNR TYPE STRING,
FDNUM TYPE STRING,
ENAVN TYPE STRING,
FNAVN TYPE STRING,
STRAS TYPE STRING,
PSTNR TYPE STRING,
BOKOM TYPE STRING,
ADRS TYPE STRING,
ANRED TYPE STRING,
NAME1 TYPE STRING,
NAME2 TYPE STRING,
NAME3 TYPE STRING,
NAME4 TYPE STRING,
STRAS TYPE STRING,
PFACH TYPE STRING,
PSTL2 TYPE STRING,
PFORT TYPE STRING,
LAND1 TYPE STRING,
PSTLZ TYPE STRING,
ORT01 TYPE STRING,
ORT02 TYPE STRING,
REGIO TYPE STRING,
SPRAS TYPE STRING,
INLND TYPE STRING,
ANZZL TYPE STRING,
PRIOR TYPE STRING,
WAREN TYPE STRING,
LINE0 TYPE STRING,
LINE1 TYPE STRING,
LINE2 TYPE STRING,
LINE3 TYPE STRING,
LINE4 TYPE STRING,
LINE5 TYPE STRING,
LINE6 TYPE STRING,
LINE7 TYPE STRING,
LINE8 TYPE STRING,
LINE9 TYPE STRING,
LINEK TYPE STRING,
LINED TYPE STRING,
LINED0 TYPE STRING,
PO_BOX_LOBBY TYPE STRING,
DELI_SERV_TYPE TYPE STRING,
DELI_SERV_NUMBER TYPE STRING,
COUNTY TYPE STRING,
TOWNSHIP TYPE STRING,
TRYNR TYPE STRING,
TRYNA TYPE STRING,
SJOEM TYPE STRING,
HIRE TYPE STRING,
FIRE TYPE STRING,
YRKE TYPE STRING,
YRKET TYPE STRING,
ORGNR TYPE STRING,
ERADR TYPE STRING,
ANRED TYPE STRING,
NAME1 TYPE STRING,
NAME2 TYPE STRING,
NAME3 TYPE STRING,
NAME4 TYPE STRING,
STRAS TYPE STRING,
PFACH TYPE STRING,
PSTL2 TYPE STRING,
PFORT TYPE STRING,
LAND1 TYPE STRING,
PSTLZ TYPE STRING,
ORT01 TYPE STRING,
ORT02 TYPE STRING,
REGIO TYPE STRING,
SPRAS TYPE STRING,
INLND TYPE STRING,
ANZZL TYPE STRING,
PRIOR TYPE STRING,
WAREN TYPE STRING,
LINE0 TYPE STRING,
LINE1 TYPE STRING,
LINE2 TYPE STRING,
LINE3 TYPE STRING,
LINE4 TYPE STRING,
LINE5 TYPE STRING,
LINE6 TYPE STRING,
LINE7 TYPE STRING,
LINE8 TYPE STRING,
LINE9 TYPE STRING,
LINEK TYPE STRING,
LINED TYPE STRING,
LINED0 TYPE STRING,
PO_BOX_LOBBY TYPE STRING,
DELI_SERV_TYPE TYPE STRING,
DELI_SERV_NUMBER TYPE STRING,
COUNTY TYPE STRING,
TOWNSHIP TYPE STRING,
BANKN TYPE STRING,
MUNIC TYPE STRING,
MNAVN TYPE STRING,
SONE TYPE STRING,
TABNO TYPE STRING,
PETAX TYPE STRING,
EMAIL TYPE STRING,
PSCHEME TYPE STRING,END OF T_EKKO_STR. DATA: WA_P20_RMB_EE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P20_RMB_EE_STR-PERNR sy-vline
WA_P20_RMB_EE_STR-FDNUM sy-vline
WA_P20_RMB_EE_STR-ENAVN sy-vline
WA_P20_RMB_EE_STR-FNAVN sy-vline
WA_P20_RMB_EE_STR-STRAS sy-vline
WA_P20_RMB_EE_STR-PSTNR sy-vline
WA_P20_RMB_EE_STR-BOKOM sy-vline
WA_P20_RMB_EE_STR-ADRS sy-vline
WA_P20_RMB_EE_STR-ANRED sy-vline
WA_P20_RMB_EE_STR-NAME1 sy-vline
WA_P20_RMB_EE_STR-NAME2 sy-vline
WA_P20_RMB_EE_STR-NAME3 sy-vline
WA_P20_RMB_EE_STR-NAME4 sy-vline
WA_P20_RMB_EE_STR-STRAS sy-vline
WA_P20_RMB_EE_STR-PFACH sy-vline
WA_P20_RMB_EE_STR-PSTL2 sy-vline
WA_P20_RMB_EE_STR-PFORT sy-vline
WA_P20_RMB_EE_STR-LAND1 sy-vline
WA_P20_RMB_EE_STR-PSTLZ sy-vline
WA_P20_RMB_EE_STR-ORT01 sy-vline
WA_P20_RMB_EE_STR-ORT02 sy-vline
WA_P20_RMB_EE_STR-REGIO sy-vline
WA_P20_RMB_EE_STR-SPRAS sy-vline
WA_P20_RMB_EE_STR-INLND sy-vline
WA_P20_RMB_EE_STR-ANZZL sy-vline
WA_P20_RMB_EE_STR-PRIOR sy-vline
WA_P20_RMB_EE_STR-WAREN sy-vline
WA_P20_RMB_EE_STR-LINE0 sy-vline
WA_P20_RMB_EE_STR-LINE1 sy-vline
WA_P20_RMB_EE_STR-LINE2 sy-vline
WA_P20_RMB_EE_STR-LINE3 sy-vline
WA_P20_RMB_EE_STR-LINE4 sy-vline
WA_P20_RMB_EE_STR-LINE5 sy-vline
WA_P20_RMB_EE_STR-LINE6 sy-vline
WA_P20_RMB_EE_STR-LINE7 sy-vline
WA_P20_RMB_EE_STR-LINE8 sy-vline
WA_P20_RMB_EE_STR-LINE9 sy-vline
WA_P20_RMB_EE_STR-LINEK sy-vline
WA_P20_RMB_EE_STR-LINED sy-vline
WA_P20_RMB_EE_STR-LINED0 sy-vline
WA_P20_RMB_EE_STR-PO_BOX_LOBBY sy-vline
WA_P20_RMB_EE_STR-DELI_SERV_TYPE sy-vline
WA_P20_RMB_EE_STR-DELI_SERV_NUMBER sy-vline
WA_P20_RMB_EE_STR-COUNTY sy-vline
WA_P20_RMB_EE_STR-TOWNSHIP sy-vline
WA_P20_RMB_EE_STR-TRYNR sy-vline
WA_P20_RMB_EE_STR-TRYNA sy-vline
WA_P20_RMB_EE_STR-SJOEM sy-vline
WA_P20_RMB_EE_STR-HIRE sy-vline
WA_P20_RMB_EE_STR-FIRE sy-vline
WA_P20_RMB_EE_STR-YRKE sy-vline
WA_P20_RMB_EE_STR-YRKET sy-vline
WA_P20_RMB_EE_STR-ORGNR sy-vline
WA_P20_RMB_EE_STR-ERADR sy-vline
WA_P20_RMB_EE_STR-ANRED sy-vline
WA_P20_RMB_EE_STR-NAME1 sy-vline
WA_P20_RMB_EE_STR-NAME2 sy-vline
WA_P20_RMB_EE_STR-NAME3 sy-vline
WA_P20_RMB_EE_STR-NAME4 sy-vline
WA_P20_RMB_EE_STR-STRAS sy-vline
WA_P20_RMB_EE_STR-PFACH sy-vline
WA_P20_RMB_EE_STR-PSTL2 sy-vline
WA_P20_RMB_EE_STR-PFORT sy-vline
WA_P20_RMB_EE_STR-LAND1 sy-vline
WA_P20_RMB_EE_STR-PSTLZ sy-vline
WA_P20_RMB_EE_STR-ORT01 sy-vline
WA_P20_RMB_EE_STR-ORT02 sy-vline
WA_P20_RMB_EE_STR-REGIO sy-vline
WA_P20_RMB_EE_STR-SPRAS sy-vline
WA_P20_RMB_EE_STR-INLND sy-vline
WA_P20_RMB_EE_STR-ANZZL sy-vline
WA_P20_RMB_EE_STR-PRIOR sy-vline
WA_P20_RMB_EE_STR-WAREN sy-vline
WA_P20_RMB_EE_STR-LINE0 sy-vline
WA_P20_RMB_EE_STR-LINE1 sy-vline
WA_P20_RMB_EE_STR-LINE2 sy-vline
WA_P20_RMB_EE_STR-LINE3 sy-vline
WA_P20_RMB_EE_STR-LINE4 sy-vline
WA_P20_RMB_EE_STR-LINE5 sy-vline
WA_P20_RMB_EE_STR-LINE6 sy-vline
WA_P20_RMB_EE_STR-LINE7 sy-vline
WA_P20_RMB_EE_STR-LINE8 sy-vline
WA_P20_RMB_EE_STR-LINE9 sy-vline
WA_P20_RMB_EE_STR-LINEK sy-vline
WA_P20_RMB_EE_STR-LINED sy-vline
WA_P20_RMB_EE_STR-LINED0 sy-vline
WA_P20_RMB_EE_STR-PO_BOX_LOBBY sy-vline
WA_P20_RMB_EE_STR-DELI_SERV_TYPE sy-vline
WA_P20_RMB_EE_STR-DELI_SERV_NUMBER sy-vline
WA_P20_RMB_EE_STR-COUNTY sy-vline
WA_P20_RMB_EE_STR-TOWNSHIP sy-vline
WA_P20_RMB_EE_STR-BANKN sy-vline
WA_P20_RMB_EE_STR-MUNIC sy-vline
WA_P20_RMB_EE_STR-MNAVN sy-vline
WA_P20_RMB_EE_STR-SONE sy-vline
WA_P20_RMB_EE_STR-TABNO sy-vline
WA_P20_RMB_EE_STR-PETAX sy-vline
WA_P20_RMB_EE_STR-EMAIL sy-vline
WA_P20_RMB_EE_STR-PSCHEME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.