ABAP Select data from SAP table P1772_EXP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P1772_EXP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P1772_EXP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P1772_EXP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P1772_EXP TYPE STANDARD TABLE OF P1772_EXP,
      WA_P1772_EXP TYPE P1772_EXP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P1772_EXP> TYPE P1772_EXP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P1772_EXP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P1772_EXP
  INTO TABLE IT_P1772_EXP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P1772_EXP
*  INTO TABLE @DATA(IT_P1772_EXP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P1772_EXP INDEX 1 INTO DATA(WA_P1772_EXP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P1772_EXP ASSIGNING <P1772_EXP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P1772_EXP>-MANDT = 1.
<P1772_EXP>-PLVAR = 1.
<P1772_EXP>-OTYPE = 1.
<P1772_EXP>-OBJID = 1.
<P1772_EXP>-INFTY = 1.
ENDLOOP.

LOOP AT IT_P1772_EXP INTO WA_P1772_EXP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P1772_EXP-SUBTY, sy-vline,
WA_P1772_EXP-ISTAT, sy-vline,
WA_P1772_EXP-PRIOX, sy-vline,
WA_P1772_EXP-BEGDA, sy-vline,
WA_P1772_EXP-ENDDA, sy-vline,
WA_P1772_EXP-VARYF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P1772_EXP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P1772_EXP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P1772_EXP INTO WA_P1772_EXP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P1772_EXP_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
PRIOX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
PROGSTATUS_SY TYPE STRING,
PROGSTATUS_OR TYPE STRING,
PROG_BEGDA TYPE STRING,
PROG_ENDDA TYPE STRING,
PROG_RES TYPE STRING,
CHKTIMEPNT TYPE STRING,
CHKDATE TYPE STRING,
CHKTIMECLC TYPE STRING,
SINDX_1 TYPE STRING,
SINDX_2 TYPE STRING,
SINDX_3 TYPE STRING,
SINDX_4 TYPE STRING,
SINDX_5 TYPE STRING,
SINDX_6 TYPE STRING,
SINDX_7 TYPE STRING,
SINDX_8 TYPE STRING,
SINDX_9 TYPE STRING,
SINDX_10 TYPE STRING,
SINDX_11 TYPE STRING,
SINDX_12 TYPE STRING,
SINDX_13 TYPE STRING,
SINDX_14 TYPE STRING,
SINDX_15 TYPE STRING,
SINDX_16 TYPE STRING,
SINDX_17 TYPE STRING,
SINDX_18 TYPE STRING,
SINDX_19 TYPE STRING,
SINDX_20 TYPE STRING,
SFLAG_1 TYPE STRING,
SFLAG_2 TYPE STRING,
SFLAG_3 TYPE STRING,
SFLAG_4 TYPE STRING,
SFLAG_5 TYPE STRING,
AKTFLAG TYPE STRING,
ACLEVEL TYPE STRING,
AYEAR TYPE STRING,
PERID TYPE STRING,
TABNR TYPE STRING,
TABSEQNR TYPE STRING,
RC_ID TYPE STRING,
RM_ID TYPE STRING,
RM_RESULT TYPE STRING,
RE_ID TYPE STRING,
RE_RESULT TYPE STRING,
RULEMSG_MSGCLASS TYPE STRING,
RULEMSG_TXTNR TYPE STRING,
RULEMSG_MSGTYP TYPE STRING,
RULEMSG_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_P1772_EXP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P1772_EXP_STR-MANDT sy-vline
WA_P1772_EXP_STR-PLVAR sy-vline
WA_P1772_EXP_STR-OTYPE sy-vline
WA_P1772_EXP_STR-OBJID sy-vline
WA_P1772_EXP_STR-INFTY sy-vline
WA_P1772_EXP_STR-SUBTY sy-vline
WA_P1772_EXP_STR-ISTAT sy-vline
WA_P1772_EXP_STR-PRIOX sy-vline
WA_P1772_EXP_STR-BEGDA sy-vline
WA_P1772_EXP_STR-ENDDA sy-vline
WA_P1772_EXP_STR-VARYF sy-vline
WA_P1772_EXP_STR-SEQNR sy-vline
WA_P1772_EXP_STR-AEDTM sy-vline
WA_P1772_EXP_STR-UNAME sy-vline
WA_P1772_EXP_STR-REASN sy-vline
WA_P1772_EXP_STR-HISTO sy-vline
WA_P1772_EXP_STR-ITXNR sy-vline
WA_P1772_EXP_STR-PROGSTATUS_SY sy-vline
WA_P1772_EXP_STR-PROGSTATUS_OR sy-vline
WA_P1772_EXP_STR-PROG_BEGDA sy-vline
WA_P1772_EXP_STR-PROG_ENDDA sy-vline
WA_P1772_EXP_STR-PROG_RES sy-vline
WA_P1772_EXP_STR-CHKTIMEPNT sy-vline
WA_P1772_EXP_STR-CHKDATE sy-vline
WA_P1772_EXP_STR-CHKTIMECLC sy-vline
WA_P1772_EXP_STR-SINDX_1 sy-vline
WA_P1772_EXP_STR-SINDX_2 sy-vline
WA_P1772_EXP_STR-SINDX_3 sy-vline
WA_P1772_EXP_STR-SINDX_4 sy-vline
WA_P1772_EXP_STR-SINDX_5 sy-vline
WA_P1772_EXP_STR-SINDX_6 sy-vline
WA_P1772_EXP_STR-SINDX_7 sy-vline
WA_P1772_EXP_STR-SINDX_8 sy-vline
WA_P1772_EXP_STR-SINDX_9 sy-vline
WA_P1772_EXP_STR-SINDX_10 sy-vline
WA_P1772_EXP_STR-SINDX_11 sy-vline
WA_P1772_EXP_STR-SINDX_12 sy-vline
WA_P1772_EXP_STR-SINDX_13 sy-vline
WA_P1772_EXP_STR-SINDX_14 sy-vline
WA_P1772_EXP_STR-SINDX_15 sy-vline
WA_P1772_EXP_STR-SINDX_16 sy-vline
WA_P1772_EXP_STR-SINDX_17 sy-vline
WA_P1772_EXP_STR-SINDX_18 sy-vline
WA_P1772_EXP_STR-SINDX_19 sy-vline
WA_P1772_EXP_STR-SINDX_20 sy-vline
WA_P1772_EXP_STR-SFLAG_1 sy-vline
WA_P1772_EXP_STR-SFLAG_2 sy-vline
WA_P1772_EXP_STR-SFLAG_3 sy-vline
WA_P1772_EXP_STR-SFLAG_4 sy-vline
WA_P1772_EXP_STR-SFLAG_5 sy-vline
WA_P1772_EXP_STR-AKTFLAG sy-vline
WA_P1772_EXP_STR-ACLEVEL sy-vline
WA_P1772_EXP_STR-AYEAR sy-vline
WA_P1772_EXP_STR-PERID sy-vline
WA_P1772_EXP_STR-TABNR sy-vline
WA_P1772_EXP_STR-TABSEQNR sy-vline
WA_P1772_EXP_STR-RC_ID sy-vline
WA_P1772_EXP_STR-RM_ID sy-vline
WA_P1772_EXP_STR-RM_RESULT sy-vline
WA_P1772_EXP_STR-RE_ID sy-vline
WA_P1772_EXP_STR-RE_RESULT sy-vline
WA_P1772_EXP_STR-RULEMSG_MSGCLASS sy-vline
WA_P1772_EXP_STR-RULEMSG_TXTNR sy-vline
WA_P1772_EXP_STR-RULEMSG_MSGTYP sy-vline
WA_P1772_EXP_STR-RULEMSG_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.