ABAP Select data from SAP table P1714 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P1714 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P1714. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P1714 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P1714 TYPE STANDARD TABLE OF P1714,
      WA_P1714 TYPE P1714,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P1714> TYPE P1714.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P1714.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P1714
  INTO TABLE IT_P1714.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P1714
*  INTO TABLE @DATA(IT_P17142).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P1714 INDEX 1 INTO DATA(WA_P17142).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P1714 ASSIGNING <P1714>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P1714>-MANDT = 1.
<P1714>-PLVAR = 1.
<P1714>-OTYPE = 1.
<P1714>-OBJID = 1.
<P1714>-INFTY = 1.
ENDLOOP.

LOOP AT IT_P1714 INTO WA_P1714.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P1714-SUBTY, sy-vline,
WA_P1714-ISTAT, sy-vline,
WA_P1714-PRIOX, sy-vline,
WA_P1714-BEGDA, sy-vline,
WA_P1714-ENDDA, sy-vline,
WA_P1714-VARYF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P1714 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P1714 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P1714 INTO WA_P1714. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P1714_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
PRIOX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
INST_OTYPE TYPE STRING,
INST_OBJID TYPE STRING,
PROG_OBJID TYPE STRING,
FROM_YEAR TYPE STRING,
TO_YEAR TYPE STRING,
FROM_SESSION TYPE STRING,
TO_SESSION TYPE STRING,
CONTACT_OTYPE TYPE STRING,
CONTACT_OBJID TYPE STRING,
APPROVE_DATE TYPE STRING,
ENDOFSTAY TYPE STRING,
DISCIPLINE TYPE STRING,
EXCH_STATUS TYPE STRING,
EXCH_CHOICE TYPE STRING,
HOMEDEGRTYPE TYPE STRING,
STUDCATEGORY TYPE STRING,
ADDINFO TYPE STRING,END OF T_EKKO_STR. DATA: WA_P1714_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P1714_STR-MANDT sy-vline
WA_P1714_STR-PLVAR sy-vline
WA_P1714_STR-OTYPE sy-vline
WA_P1714_STR-OBJID sy-vline
WA_P1714_STR-INFTY sy-vline
WA_P1714_STR-SUBTY sy-vline
WA_P1714_STR-ISTAT sy-vline
WA_P1714_STR-PRIOX sy-vline
WA_P1714_STR-BEGDA sy-vline
WA_P1714_STR-ENDDA sy-vline
WA_P1714_STR-VARYF sy-vline
WA_P1714_STR-SEQNR sy-vline
WA_P1714_STR-AEDTM sy-vline
WA_P1714_STR-UNAME sy-vline
WA_P1714_STR-REASN sy-vline
WA_P1714_STR-HISTO sy-vline
WA_P1714_STR-ITXNR sy-vline
WA_P1714_STR-INST_OTYPE sy-vline
WA_P1714_STR-INST_OBJID sy-vline
WA_P1714_STR-PROG_OBJID sy-vline
WA_P1714_STR-FROM_YEAR sy-vline
WA_P1714_STR-TO_YEAR sy-vline
WA_P1714_STR-FROM_SESSION sy-vline
WA_P1714_STR-TO_SESSION sy-vline
WA_P1714_STR-CONTACT_OTYPE sy-vline
WA_P1714_STR-CONTACT_OBJID sy-vline
WA_P1714_STR-APPROVE_DATE sy-vline
WA_P1714_STR-ENDOFSTAY sy-vline
WA_P1714_STR-DISCIPLINE sy-vline
WA_P1714_STR-EXCH_STATUS sy-vline
WA_P1714_STR-EXCH_CHOICE sy-vline
WA_P1714_STR-HOMEDEGRTYPE sy-vline
WA_P1714_STR-STUDCATEGORY sy-vline
WA_P1714_STR-ADDINFO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.