ABAP Select data from SAP table P1676 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P1676 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P1676. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P1676 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P1676 TYPE STANDARD TABLE OF P1676,
      WA_P1676 TYPE P1676,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P1676> TYPE P1676.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P1676.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P1676
  INTO TABLE IT_P1676.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P1676
*  INTO TABLE @DATA(IT_P16762).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P1676 INDEX 1 INTO DATA(WA_P16762).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P1676 ASSIGNING <P1676>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P1676>-MANDT = 1.
<P1676>-PLVAR = 1.
<P1676>-OTYPE = 1.
<P1676>-OBJID = 1.
<P1676>-INFTY = 1.
ENDLOOP.

LOOP AT IT_P1676 INTO WA_P1676.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P1676-SUBTY, sy-vline,
WA_P1676-ISTAT, sy-vline,
WA_P1676-PRIOX, sy-vline,
WA_P1676-BEGDA, sy-vline,
WA_P1676-ENDDA, sy-vline,
WA_P1676-VARYF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P1676 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P1676 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P1676 INTO WA_P1676. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P1676_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
PRIOX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
REGIME TYPE STRING,
FUCLVL TYPE STRING,
EDARE TYPE STRING,
PTSAS TYPE STRING,
FTCON TYPE STRING,
MAPPS TYPE STRING,
RASCA TYPE STRING,
RADCOD01 TYPE STRING,
RADCOD02 TYPE STRING,
RADCOD03 TYPE STRING,
RADCOD04 TYPE STRING,
RADCOD05 TYPE STRING,
RADCOD06 TYPE STRING,
RADCOD07 TYPE STRING,
RADCOD08 TYPE STRING,
RADCOD09 TYPE STRING,
RADCOD10 TYPE STRING,
RADCOD11 TYPE STRING,
RADCOD12 TYPE STRING,
RADCOD13 TYPE STRING,
RADCOD14 TYPE STRING,
RADCOD15 TYPE STRING,
RADCOD16 TYPE STRING,
RADCOD17 TYPE STRING,
RADCOD18 TYPE STRING,
RADCOD19 TYPE STRING,
RADCOD20 TYPE STRING,END OF T_EKKO_STR. DATA: WA_P1676_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P1676_STR-MANDT sy-vline
WA_P1676_STR-PLVAR sy-vline
WA_P1676_STR-OTYPE sy-vline
WA_P1676_STR-OBJID sy-vline
WA_P1676_STR-INFTY sy-vline
WA_P1676_STR-SUBTY sy-vline
WA_P1676_STR-ISTAT sy-vline
WA_P1676_STR-PRIOX sy-vline
WA_P1676_STR-BEGDA sy-vline
WA_P1676_STR-ENDDA sy-vline
WA_P1676_STR-VARYF sy-vline
WA_P1676_STR-SEQNR sy-vline
WA_P1676_STR-AEDTM sy-vline
WA_P1676_STR-UNAME sy-vline
WA_P1676_STR-REASN sy-vline
WA_P1676_STR-HISTO sy-vline
WA_P1676_STR-ITXNR sy-vline
WA_P1676_STR-REGIME sy-vline
WA_P1676_STR-FUCLVL sy-vline
WA_P1676_STR-EDARE sy-vline
WA_P1676_STR-PTSAS sy-vline
WA_P1676_STR-FTCON sy-vline
WA_P1676_STR-MAPPS sy-vline
WA_P1676_STR-RASCA sy-vline
WA_P1676_STR-RADCOD01 sy-vline
WA_P1676_STR-RADCOD02 sy-vline
WA_P1676_STR-RADCOD03 sy-vline
WA_P1676_STR-RADCOD04 sy-vline
WA_P1676_STR-RADCOD05 sy-vline
WA_P1676_STR-RADCOD06 sy-vline
WA_P1676_STR-RADCOD07 sy-vline
WA_P1676_STR-RADCOD08 sy-vline
WA_P1676_STR-RADCOD09 sy-vline
WA_P1676_STR-RADCOD10 sy-vline
WA_P1676_STR-RADCOD11 sy-vline
WA_P1676_STR-RADCOD12 sy-vline
WA_P1676_STR-RADCOD13 sy-vline
WA_P1676_STR-RADCOD14 sy-vline
WA_P1676_STR-RADCOD15 sy-vline
WA_P1676_STR-RADCOD16 sy-vline
WA_P1676_STR-RADCOD17 sy-vline
WA_P1676_STR-RADCOD18 sy-vline
WA_P1676_STR-RADCOD19 sy-vline
WA_P1676_STR-RADCOD20 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.