ABAP Select data from SAP table P12BOW_REC2B_1_2009 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP P12BOW_REC2B_1_2009 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P12BOW_REC2B_1_2009. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the P12BOW_REC2B_1_2009 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_P12BOW_REC2B_1_2009 TYPE STANDARD TABLE OF P12BOW_REC2B_1_2009, WA_P12BOW_REC2B_1_2009 TYPE P12BOW_REC2B_1_2009, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <P12BOW_REC2B_1_2009> TYPE P12BOW_REC2B_1_2009. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_P12BOW_REC2B_1_2009. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM P12BOW_REC2B_1_2009 INTO TABLE IT_P12BOW_REC2B_1_2009. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM P12BOW_REC2B_1_2009 * INTO TABLE @DATA(IT_P12BOW_REC2B_1_20092). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_P12BOW_REC2B_1_2009 INDEX 1 INTO DATA(WA_P12BOW_REC2B_1_20092). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_P12BOW_REC2B_1_2009 ASSIGNING <P12BOW_REC2B_1_2009>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<P12BOW_REC2B_1_2009>-BTRID = 1.
<P12BOW_REC2B_1_2009>-BTIYR = 1.
<P12BOW_REC2B_1_2009>-BTREG = 1.
<P12BOW_REC2B_1_2009>-BTRET = 1.
<P12BOW_REC2B_1_2009>-BTADM = 1.
ENDLOOP. LOOP AT IT_P12BOW_REC2B_1_2009 INTO WA_P12BOW_REC2B_1_2009. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_P12BOW_REC2B_1_2009-BTNM9, sy-vline,
WA_P12BOW_REC2B_1_2009-BTCNY, sy-vline,
WA_P12BOW_REC2B_1_2009-BTVOU, sy-vline,
WA_P12BOW_REC2B_1_2009-BTVSQ, sy-vline,
WA_P12BOW_REC2B_1_2009-BFPER, sy-vline,
WA_P12BOW_REC2B_1_2009-BFNRG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P12BOW_REC2B_1_2009 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P12BOW_REC2B_1_2009 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P12BOW_REC2B_1_2009 INTO WA_P12BOW_REC2B_1_2009. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field BTIYR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_P12BOW_REC2B_1_2009-BTIYR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P12BOW_REC2B_1_2009-BTIYR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P12BOW_REC2B_1_2009_STR,
BTRID TYPE STRING,
BTIYR TYPE STRING,
BTREG TYPE STRING,
BTRET TYPE STRING,
BTADM TYPE STRING,
BTNM9 TYPE STRING,
BTCNY TYPE STRING,
BTVOU TYPE STRING,
BTVSQ TYPE STRING,
BFPER TYPE STRING,
BFNRG TYPE STRING,
BFBIR TYPE STRING,
BFNAM TYPE STRING,
BFSPS TYPE STRING,
BFADR TYPE STRING,
BFPCD TYPE STRING,
BFLOC TYPE STRING,
BFCTY TYPE STRING,
BFMAR TYPE STRING,
BFFAM TYPE STRING,
BFENF TYPE STRING,
BFOCH TYPE STRING,
BFOFS TYPE STRING,
BFSPH TYPE STRING,
F2025 TYPE STRING,
BFHAN TYPE STRING,
BFLAN TYPE STRING,
BFCRC TYPE STRING,
BF325 TYPE STRING,
BFBIP TYPE STRING,
BFFPC TYPE STRING,
VORSW TYPE STRING,END OF T_EKKO_STR. DATA: WA_P12BOW_REC2B_1_2009_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P12BOW_REC2B_1_2009_STR-BTRID sy-vline
WA_P12BOW_REC2B_1_2009_STR-BTIYR sy-vline
WA_P12BOW_REC2B_1_2009_STR-BTREG sy-vline
WA_P12BOW_REC2B_1_2009_STR-BTRET sy-vline
WA_P12BOW_REC2B_1_2009_STR-BTADM sy-vline
WA_P12BOW_REC2B_1_2009_STR-BTNM9 sy-vline
WA_P12BOW_REC2B_1_2009_STR-BTCNY sy-vline
WA_P12BOW_REC2B_1_2009_STR-BTVOU sy-vline
WA_P12BOW_REC2B_1_2009_STR-BTVSQ sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFPER sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFNRG sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFBIR sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFNAM sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFSPS sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFADR sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFPCD sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFLOC sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFCTY sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFMAR sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFFAM sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFENF sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFOCH sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFOFS sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFSPH sy-vline
WA_P12BOW_REC2B_1_2009_STR-F2025 sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFHAN sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFLAN sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFCRC sy-vline
WA_P12BOW_REC2B_1_2009_STR-BF325 sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFBIP sy-vline
WA_P12BOW_REC2B_1_2009_STR-BFFPC sy-vline
WA_P12BOW_REC2B_1_2009_STR-VORSW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.