ABAP Select data from SAP table P1282 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P1282 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P1282. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P1282 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P1282 TYPE STANDARD TABLE OF P1282,
      WA_P1282 TYPE P1282,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P1282> TYPE P1282.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P1282.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P1282
  INTO TABLE IT_P1282.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P1282
*  INTO TABLE @DATA(IT_P12822).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P1282 INDEX 1 INTO DATA(WA_P12822).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P1282 ASSIGNING <P1282>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P1282>-CLIENT = 1.
<P1282>-OBJTYPE = 1.
<P1282>-EVENT = 1.
<P1282>-RECTYPE = 1.
<P1282>-RECFB = 1.
ENDLOOP.

LOOP AT IT_P1282 INTO WA_P1282.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P1282-CHECKFB, sy-vline,
WA_P1282-RECGETFB, sy-vline,
WA_P1282-GLOBAL, sy-vline,
WA_P1282-ENABLED, sy-vline,
WA_P1282-RFCDEST, sy-vline,
WA_P1282-LOGSYS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P1282 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P1282 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P1282 INTO WA_P1282. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P1282-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P1282-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P1282_STR,
CLIENT TYPE STRING,
OBJTYPE TYPE STRING,
EVENT TYPE STRING,
RECTYPE TYPE STRING,
RECFB TYPE STRING,
CHECKFB TYPE STRING,
RECGETFB TYPE STRING,
GLOBAL TYPE STRING,
ENABLED TYPE STRING,
RFCDEST TYPE STRING,
LOGSYS TYPE STRING,
Q_ENABLE TYPE STRING,
REC_ERROR TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,END OF T_EKKO_STR. DATA: WA_P1282_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P1282_STR-CLIENT sy-vline
WA_P1282_STR-OBJTYPE sy-vline
WA_P1282_STR-EVENT sy-vline
WA_P1282_STR-RECTYPE sy-vline
WA_P1282_STR-RECFB sy-vline
WA_P1282_STR-CHECKFB sy-vline
WA_P1282_STR-RECGETFB sy-vline
WA_P1282_STR-GLOBAL sy-vline
WA_P1282_STR-ENABLED sy-vline
WA_P1282_STR-RFCDEST sy-vline
WA_P1282_STR-LOGSYS sy-vline
WA_P1282_STR-Q_ENABLE sy-vline
WA_P1282_STR-REC_ERROR sy-vline
WA_P1282_STR-BEGDA sy-vline
WA_P1282_STR-ENDDA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.