ABAP Select data from SAP table P08P_TPS_ADDITION_GRID into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P08P_TPS_ADDITION_GRID table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P08P_TPS_ADDITION_GRID. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P08P_TPS_ADDITION_GRID table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P08P_TPS_ADDITION_GRID TYPE STANDARD TABLE OF P08P_TPS_ADDITION_GRID,
      WA_P08P_TPS_ADDITION_GRID TYPE P08P_TPS_ADDITION_GRID,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P08P_TPS_ADDITION_GRID> TYPE P08P_TPS_ADDITION_GRID.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P08P_TPS_ADDITION_GRID.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P08P_TPS_ADDITION_GRID
  INTO TABLE IT_P08P_TPS_ADDITION_GRID.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P08P_TPS_ADDITION_GRID
*  INTO TABLE @DATA(IT_P08P_TPS_ADDITION_GRID2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P08P_TPS_ADDITION_GRID INDEX 1 INTO DATA(WA_P08P_TPS_ADDITION_GRID2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P08P_TPS_ADDITION_GRID ASSIGNING <P08P_TPS_ADDITION_GRID>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P08P_TPS_ADDITION_GRID>-PERNR = 1.
<P08P_TPS_ADDITION_GRID>-TDFES = 1.
<P08P_TPS_ADDITION_GRID>-GENDER = 1.
<P08P_TPS_ADDITION_GRID>-PERNI = 1.
<P08P_TPS_ADDITION_GRID>-SNAME = 1.
ENDLOOP.

LOOP AT IT_P08P_TPS_ADDITION_GRID INTO WA_P08P_TPS_ADDITION_GRID.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P08P_TPS_ADDITION_GRID-INITS, sy-vline,
WA_P08P_TPS_ADDITION_GRID-BNAME, sy-vline,
WA_P08P_TPS_ADDITION_GRID-BDATE, sy-vline,
WA_P08P_TPS_ADDITION_GRID-AREAC, sy-vline,
WA_P08P_TPS_ADDITION_GRID-ME, sy-vline,
WA_P08P_TPS_ADDITION_GRID-PERNR_T, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P08P_TPS_ADDITION_GRID you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P08P_TPS_ADDITION_GRID TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P08P_TPS_ADDITION_GRID INTO WA_P08P_TPS_ADDITION_GRID. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PDATE, internal->external for field BDATE CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_P08P_TPS_ADDITION_GRID-BDATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08P_TPS_ADDITION_GRID-BDATE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P08P_TPS_ADDITION_GRID_STR,
PERNR TYPE STRING,
TDFES TYPE STRING,
GENDER TYPE STRING,
PERNI TYPE STRING,
SNAME TYPE STRING,
INITS TYPE STRING,
BNAME TYPE STRING,
BDATE TYPE STRING,
AREAC TYPE STRING,
ME TYPE STRING,
PERNR_T TYPE STRING,
FILL1 TYPE STRING,
ADDCO TYPE STRING,
REFUND TYPE STRING,
NOTES TYPE STRING,
FYEAR TYPE STRING,
FILL2 TYPE STRING,
REFER TYPE STRING,
ESTAB TYPE STRING,
FILL3 TYPE STRING,
RECTY TYPE STRING,
FILL4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_P08P_TPS_ADDITION_GRID_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-PERNR sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-TDFES sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-GENDER sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-PERNI sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-SNAME sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-INITS sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-BNAME sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-BDATE sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-AREAC sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-ME sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-PERNR_T sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-FILL1 sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-ADDCO sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-REFUND sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-NOTES sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-FYEAR sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-FILL2 sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-REFER sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-ESTAB sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-FILL3 sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-RECTY sy-vline
WA_P08P_TPS_ADDITION_GRID_STR-FILL4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.