ABAP Select data from SAP table P08P_FEATURES2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P08P_FEATURES2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P08P_FEATURES2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P08P_FEATURES2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P08P_FEATURES2 TYPE STANDARD TABLE OF P08P_FEATURES2,
      WA_P08P_FEATURES2 TYPE P08P_FEATURES2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P08P_FEATURES2> TYPE P08P_FEATURES2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P08P_FEATURES2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P08P_FEATURES2
  INTO TABLE IT_P08P_FEATURES2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P08P_FEATURES2
*  INTO TABLE @DATA(IT_P08P_FEATURES22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P08P_FEATURES2 INDEX 1 INTO DATA(WA_P08P_FEATURES22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P08P_FEATURES2 ASSIGNING <P08P_FEATURES2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P08P_FEATURES2>-08TCE = 1.
<P08P_FEATURES2>-BUKRS = 1.
<P08P_FEATURES2>-WERKS = 1.
<P08P_FEATURES2>-BTRTL = 1.
<P08P_FEATURES2>-PERSG = 1.
ENDLOOP.

LOOP AT IT_P08P_FEATURES2 INTO WA_P08P_FEATURES2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P08P_FEATURES2-PERSK, sy-vline,
WA_P08P_FEATURES2-ABKRS, sy-vline,
WA_P08P_FEATURES2-KOSTL, sy-vline,
WA_P08P_FEATURES2-JUPER, sy-vline,
WA_P08P_FEATURES2-VDSK1, sy-vline,
WA_P08P_FEATURES2-GSBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P08P_FEATURES2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P08P_FEATURES2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P08P_FEATURES2 INTO WA_P08P_FEATURES2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P08P_FEATURES2-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08P_FEATURES2-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P08P_FEATURES2-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08P_FEATURES2-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P08P_FEATURES2-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08P_FEATURES2-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P08P_FEATURES2-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08P_FEATURES2-KOSTL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P08P_FEATURES2_STR,
08TCE TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
ABKRS TYPE STRING,
KOSTL TYPE STRING,
JUPER TYPE STRING,
VDSK1 TYPE STRING,
GSBER TYPE STRING,
08TCE_RETVAL TYPE STRING,
08TIE TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
ABKRS TYPE STRING,
KOSTL TYPE STRING,
JUPER TYPE STRING,
VDSK1 TYPE STRING,
GSBER TYPE STRING,
08TIE_RETVAL TYPE STRING,
08TEA TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
MOLGA TYPE STRING,
TRFAR TYPE STRING,
TRFGB TYPE STRING,
TRFKZ TYPE STRING,
TRFGR TYPE STRING,
TRFST TYPE STRING,
08TEA_RETVAL TYPE STRING,
08TLN TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
ABKRS TYPE STRING,
KOSTL TYPE STRING,
JUPER TYPE STRING,
VDSK1 TYPE STRING,
GSBER TYPE STRING,
08TLN_RETVAL TYPE STRING,
08TSN TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
ABKRS TYPE STRING,
KOSTL TYPE STRING,
JUPER TYPE STRING,
VDSK1 TYPE STRING,
GSBER TYPE STRING,
08TSN_RETVAL TYPE STRING,
08SW1 TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
MOLGA TYPE STRING,
PERNR TYPE STRING,
ANSVH TYPE STRING,
MASSG TYPE STRING,
MASSN TYPE STRING,
08SW1_RETVAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_P08P_FEATURES2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P08P_FEATURES2_STR-08TCE sy-vline
WA_P08P_FEATURES2_STR-BUKRS sy-vline
WA_P08P_FEATURES2_STR-WERKS sy-vline
WA_P08P_FEATURES2_STR-BTRTL sy-vline
WA_P08P_FEATURES2_STR-PERSG sy-vline
WA_P08P_FEATURES2_STR-PERSK sy-vline
WA_P08P_FEATURES2_STR-ABKRS sy-vline
WA_P08P_FEATURES2_STR-KOSTL sy-vline
WA_P08P_FEATURES2_STR-JUPER sy-vline
WA_P08P_FEATURES2_STR-VDSK1 sy-vline
WA_P08P_FEATURES2_STR-GSBER sy-vline
WA_P08P_FEATURES2_STR-08TCE_RETVAL sy-vline
WA_P08P_FEATURES2_STR-08TIE sy-vline
WA_P08P_FEATURES2_STR-BUKRS sy-vline
WA_P08P_FEATURES2_STR-WERKS sy-vline
WA_P08P_FEATURES2_STR-BTRTL sy-vline
WA_P08P_FEATURES2_STR-PERSG sy-vline
WA_P08P_FEATURES2_STR-PERSK sy-vline
WA_P08P_FEATURES2_STR-ABKRS sy-vline
WA_P08P_FEATURES2_STR-KOSTL sy-vline
WA_P08P_FEATURES2_STR-JUPER sy-vline
WA_P08P_FEATURES2_STR-VDSK1 sy-vline
WA_P08P_FEATURES2_STR-GSBER sy-vline
WA_P08P_FEATURES2_STR-08TIE_RETVAL sy-vline
WA_P08P_FEATURES2_STR-08TEA sy-vline
WA_P08P_FEATURES2_STR-WERKS sy-vline
WA_P08P_FEATURES2_STR-BTRTL sy-vline
WA_P08P_FEATURES2_STR-PERSG sy-vline
WA_P08P_FEATURES2_STR-PERSK sy-vline
WA_P08P_FEATURES2_STR-MOLGA sy-vline
WA_P08P_FEATURES2_STR-TRFAR sy-vline
WA_P08P_FEATURES2_STR-TRFGB sy-vline
WA_P08P_FEATURES2_STR-TRFKZ sy-vline
WA_P08P_FEATURES2_STR-TRFGR sy-vline
WA_P08P_FEATURES2_STR-TRFST sy-vline
WA_P08P_FEATURES2_STR-08TEA_RETVAL sy-vline
WA_P08P_FEATURES2_STR-08TLN sy-vline
WA_P08P_FEATURES2_STR-BUKRS sy-vline
WA_P08P_FEATURES2_STR-WERKS sy-vline
WA_P08P_FEATURES2_STR-BTRTL sy-vline
WA_P08P_FEATURES2_STR-PERSG sy-vline
WA_P08P_FEATURES2_STR-PERSK sy-vline
WA_P08P_FEATURES2_STR-ABKRS sy-vline
WA_P08P_FEATURES2_STR-KOSTL sy-vline
WA_P08P_FEATURES2_STR-JUPER sy-vline
WA_P08P_FEATURES2_STR-VDSK1 sy-vline
WA_P08P_FEATURES2_STR-GSBER sy-vline
WA_P08P_FEATURES2_STR-08TLN_RETVAL sy-vline
WA_P08P_FEATURES2_STR-08TSN sy-vline
WA_P08P_FEATURES2_STR-BUKRS sy-vline
WA_P08P_FEATURES2_STR-WERKS sy-vline
WA_P08P_FEATURES2_STR-BTRTL sy-vline
WA_P08P_FEATURES2_STR-PERSG sy-vline
WA_P08P_FEATURES2_STR-PERSK sy-vline
WA_P08P_FEATURES2_STR-ABKRS sy-vline
WA_P08P_FEATURES2_STR-KOSTL sy-vline
WA_P08P_FEATURES2_STR-JUPER sy-vline
WA_P08P_FEATURES2_STR-VDSK1 sy-vline
WA_P08P_FEATURES2_STR-GSBER sy-vline
WA_P08P_FEATURES2_STR-08TSN_RETVAL sy-vline
WA_P08P_FEATURES2_STR-08SW1 sy-vline
WA_P08P_FEATURES2_STR-BUKRS sy-vline
WA_P08P_FEATURES2_STR-WERKS sy-vline
WA_P08P_FEATURES2_STR-BTRTL sy-vline
WA_P08P_FEATURES2_STR-PERSG sy-vline
WA_P08P_FEATURES2_STR-PERSK sy-vline
WA_P08P_FEATURES2_STR-MOLGA sy-vline
WA_P08P_FEATURES2_STR-PERNR sy-vline
WA_P08P_FEATURES2_STR-ANSVH sy-vline
WA_P08P_FEATURES2_STR-MASSG sy-vline
WA_P08P_FEATURES2_STR-MASSN sy-vline
WA_P08P_FEATURES2_STR-08SW1_RETVAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.