ABAP Select data from SAP table P08_SXP_OXP_ENTS_ALV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P08_SXP_OXP_ENTS_ALV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P08_SXP_OXP_ENTS_ALV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P08_SXP_OXP_ENTS_ALV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P08_SXP_OXP_ENTS_ALV TYPE STANDARD TABLE OF P08_SXP_OXP_ENTS_ALV,
      WA_P08_SXP_OXP_ENTS_ALV TYPE P08_SXP_OXP_ENTS_ALV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P08_SXP_OXP_ENTS_ALV> TYPE P08_SXP_OXP_ENTS_ALV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P08_SXP_OXP_ENTS_ALV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P08_SXP_OXP_ENTS_ALV
  INTO TABLE IT_P08_SXP_OXP_ENTS_ALV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P08_SXP_OXP_ENTS_ALV
*  INTO TABLE @DATA(IT_P08_SXP_OXP_ENTS_ALV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P08_SXP_OXP_ENTS_ALV INDEX 1 INTO DATA(WA_P08_SXP_OXP_ENTS_ALV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P08_SXP_OXP_ENTS_ALV ASSIGNING <P08_SXP_OXP_ENTS_ALV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P08_SXP_OXP_ENTS_ALV>-BUKRS = 1.
<P08_SXP_OXP_ENTS_ALV>-BUTXT = 1.
<P08_SXP_OXP_ENTS_ALV>-WERKS = 1.
<P08_SXP_OXP_ENTS_ALV>-NAME1 = 1.
<P08_SXP_OXP_ENTS_ALV>-BTRTL = 1.
ENDLOOP.

LOOP AT IT_P08_SXP_OXP_ENTS_ALV INTO WA_P08_SXP_OXP_ENTS_ALV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P08_SXP_OXP_ENTS_ALV-BTEXT, sy-vline,
WA_P08_SXP_OXP_ENTS_ALV-PERSG, sy-vline,
WA_P08_SXP_OXP_ENTS_ALV-PGTXT, sy-vline,
WA_P08_SXP_OXP_ENTS_ALV-PERSK, sy-vline,
WA_P08_SXP_OXP_ENTS_ALV-PKTXT, sy-vline,
WA_P08_SXP_OXP_ENTS_ALV-ORGEH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P08_SXP_OXP_ENTS_ALV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P08_SXP_OXP_ENTS_ALV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P08_SXP_OXP_ENTS_ALV INTO WA_P08_SXP_OXP_ENTS_ALV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P08_SXP_OXP_ENTS_ALV-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08_SXP_OXP_ENTS_ALV-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PDATE, internal->external for field GBDAT CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_P08_SXP_OXP_ENTS_ALV-GBDAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08_SXP_OXP_ENTS_ALV-GBDAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P08_SXP_OXP_ENTS_ALV_STR,
BUKRS TYPE STRING,
BUTXT TYPE STRING,
WERKS TYPE STRING,
NAME1 TYPE STRING,
BTRTL TYPE STRING,
BTEXT TYPE STRING,
PERSG TYPE STRING,
PGTXT TYPE STRING,
PERSK TYPE STRING,
PKTXT TYPE STRING,
ORGEH TYPE STRING,
ORGTX TYPE STRING,
KOSTL TYPE STRING,
KOSTT TYPE STRING,
ABKRS TYPE STRING,
ABKTX TYPE STRING,
PERNR TYPE STRING,
ENAME TYPE STRING,
GBDAT TYPE STRING,
GESCH TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
AWART TYPE STRING,
AWATX TYPE STRING,
ABSTY TYPE STRING,
ABSTX TYPE STRING,
UMSKD TYPE STRING,
UMSCH TYPE STRING,
SXPEV TYPE STRING,
SXPET TYPE STRING,
SXPMX TYPE STRING,
SXPST TYPE STRING,
SXPUS TYPE STRING,
SXPLE TYPE STRING,
MOLGA TYPE STRING,
COVPA TYPE STRING,
COVRU TYPE STRING,
TEXT0 TYPE STRING,
SEBEG TYPE STRING,
SEEND TYPE STRING,
SEUNI TYPE STRING,
TEXT1 TYPE STRING,
AGBEG TYPE STRING,
AGEND TYPE STRING,
AGUNI TYPE STRING,
TEXT2 TYPE STRING,
OXPEV TYPE STRING,
OXPET TYPE STRING,
OXPMX TYPE STRING,
OXPST TYPE STRING,
OXPUS TYPE STRING,
OXPLE TYPE STRING,
OXPUN TYPE STRING,
OXPUT TYPE STRING,
OXPNO TYPE STRING,END OF T_EKKO_STR. DATA: WA_P08_SXP_OXP_ENTS_ALV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-BUKRS sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-BUTXT sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-WERKS sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-NAME1 sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-BTRTL sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-BTEXT sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-PERSG sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-PGTXT sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-PERSK sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-PKTXT sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-ORGEH sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-ORGTX sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-KOSTL sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-KOSTT sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-ABKRS sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-ABKTX sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-PERNR sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-ENAME sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-GBDAT sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-GESCH sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-BEGDA sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-ENDDA sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-AWART sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-AWATX sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-ABSTY sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-ABSTX sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-UMSKD sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-UMSCH sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-SXPEV sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-SXPET sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-SXPMX sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-SXPST sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-SXPUS sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-SXPLE sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-MOLGA sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-COVPA sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-COVRU sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-TEXT0 sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-SEBEG sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-SEEND sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-SEUNI sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-TEXT1 sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-AGBEG sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-AGEND sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-AGUNI sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-TEXT2 sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-OXPEV sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-OXPET sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-OXPMX sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-OXPST sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-OXPUS sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-OXPLE sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-OXPUN sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-OXPUT sy-vline
WA_P08_SXP_OXP_ENTS_ALV_STR-OXPNO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.