ABAP Select data from SAP table P08_P60_CL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P08_P60_CL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P08_P60_CL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P08_P60_CL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P08_P60_CL TYPE STANDARD TABLE OF P08_P60_CL,
      WA_P08_P60_CL TYPE P08_P60_CL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P08_P60_CL> TYPE P08_P60_CL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P08_P60_CL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P08_P60_CL
  INTO TABLE IT_P08_P60_CL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P08_P60_CL
*  INTO TABLE @DATA(IT_P08_P60_CL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P08_P60_CL INDEX 1 INTO DATA(WA_P08_P60_CL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P08_P60_CL ASSIGNING <P08_P60_CL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P08_P60_CL>-BUKRS = 1.
<P08_P60_CL>-BUTXT = 1.
<P08_P60_CL>-WERKS = 1.
<P08_P60_CL>-NAME1 = 1.
<P08_P60_CL>-BTRTL = 1.
ENDLOOP.

LOOP AT IT_P08_P60_CL INTO WA_P08_P60_CL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P08_P60_CL-BTEXT, sy-vline,
WA_P08_P60_CL-PERSG, sy-vline,
WA_P08_P60_CL-PGTXT, sy-vline,
WA_P08_P60_CL-PERSK, sy-vline,
WA_P08_P60_CL-PKTXT, sy-vline,
WA_P08_P60_CL-ORGEH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P08_P60_CL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P08_P60_CL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P08_P60_CL INTO WA_P08_P60_CL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P08_P60_CL-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08_P60_CL-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PDATE, internal->external for field GBDAT CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_P08_P60_CL-GBDAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08_P60_CL-GBDAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field TAXYR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_P08_P60_CL-TAXYR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P08_P60_CL-TAXYR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P08_P60_CL_STR,
BUKRS TYPE STRING,
BUTXT TYPE STRING,
WERKS TYPE STRING,
NAME1 TYPE STRING,
BTRTL TYPE STRING,
BTEXT TYPE STRING,
PERSG TYPE STRING,
PGTXT TYPE STRING,
PERSK TYPE STRING,
PKTXT TYPE STRING,
ORGEH TYPE STRING,
ORGTX TYPE STRING,
KOSTL TYPE STRING,
KOSTT TYPE STRING,
ABKRS TYPE STRING,
ABKTX TYPE STRING,
PERNR TYPE STRING,
ER_NAME TYPE STRING,
ER_STRT TYPE STRING,
ER_PLZ TYPE STRING,
ER_CITY TYPE STRING,
TDREF TYPE STRING,
TDNUM TYPE STRING,
TDNME TYPE STRING,
PRMNO TYPE STRING,
ECONR TYPE STRING,
WTEXT TYPE STRING,
PERID TYPE STRING,
ACTVE TYPE STRING,
ENAME TYPE STRING,
NACHN TYPE STRING,
VORNA TYPE STRING,
MIDNM TYPE STRING,
GBDAT TYPE STRING,
GESCH TYPE STRING,
LINE0 TYPE STRING,
LINE1 TYPE STRING,
LINE2 TYPE STRING,
LINE3 TYPE STRING,
PSTLZ TYPE STRING,
LAND1 TYPE STRING,
TXCOD TYPE STRING,
M1W1I TYPE STRING,
WEEK53 TYPE STRING,
STARTD TYPE STRING,
LEAVED TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
PENID TYPE STRING,
DIRID TYPE STRING,
TREFI TYPE STRING,
SUREF TYPE STRING,
TAXYR TYPE STRING,
ERADD TYPE STRING,
LINE0_2 TYPE STRING,
LINE1_2 TYPE STRING,
LINE2_2 TYPE STRING,
LINE3_2 TYPE STRING,
PSTLZ_2 TYPE STRING,
EMAIL TYPE STRING,
EMAIL_ID TYPE STRING,
WRKNO_P60 TYPE STRING,
NICAT TYPE STRING,
CTOUT TYPE STRING,
AMTTOLEL TYPE STRING,
AMTLELEET TYPE STRING,
AMTEETERT TYPE STRING,
AMTERTUEL TYPE STRING,
AMTFROMUEL TYPE STRING,
EENIC TYPE STRING,
ERNIC TYPE STRING,
EENIR TYPE STRING,
ERNIR TYPE STRING,
EEERS TYPE STRING,
NIREF TYPE STRING,
PSCON TYPE STRING,
AMTERTUAP TYPE STRING,
AMTLELPT TYPE STRING,
WIDOR TYPE STRING,
P_EARN TYPE STRING,
C_EARN TYPE STRING,
T_EARN TYPE STRING,
P_TAX TYPE STRING,
C_TAX TYPE STRING,
T_TAX TYPE STRING,
SLOAN TYPE STRING,
TCRED TYPE STRING,
SSPBT TYPE STRING,
SMPBT TYPE STRING,
SMPRC TYPE STRING,
NICRB TYPE STRING,
NIRTO TYPE STRING,
SUPER TYPE STRING,
TOGRP TYPE STRING,
SPPBT TYPE STRING,
RCSPP TYPE STRING,
SAPBT TYPE STRING,
RCSAP TYPE STRING,
ASPBT TYPE STRING,
RCASP TYPE STRING,
PLOAN TYPE STRING,
SBPYD TYPE STRING,END OF T_EKKO_STR. DATA: WA_P08_P60_CL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P08_P60_CL_STR-BUKRS sy-vline
WA_P08_P60_CL_STR-BUTXT sy-vline
WA_P08_P60_CL_STR-WERKS sy-vline
WA_P08_P60_CL_STR-NAME1 sy-vline
WA_P08_P60_CL_STR-BTRTL sy-vline
WA_P08_P60_CL_STR-BTEXT sy-vline
WA_P08_P60_CL_STR-PERSG sy-vline
WA_P08_P60_CL_STR-PGTXT sy-vline
WA_P08_P60_CL_STR-PERSK sy-vline
WA_P08_P60_CL_STR-PKTXT sy-vline
WA_P08_P60_CL_STR-ORGEH sy-vline
WA_P08_P60_CL_STR-ORGTX sy-vline
WA_P08_P60_CL_STR-KOSTL sy-vline
WA_P08_P60_CL_STR-KOSTT sy-vline
WA_P08_P60_CL_STR-ABKRS sy-vline
WA_P08_P60_CL_STR-ABKTX sy-vline
WA_P08_P60_CL_STR-PERNR sy-vline
WA_P08_P60_CL_STR-ER_NAME sy-vline
WA_P08_P60_CL_STR-ER_STRT sy-vline
WA_P08_P60_CL_STR-ER_PLZ sy-vline
WA_P08_P60_CL_STR-ER_CITY sy-vline
WA_P08_P60_CL_STR-TDREF sy-vline
WA_P08_P60_CL_STR-TDNUM sy-vline
WA_P08_P60_CL_STR-TDNME sy-vline
WA_P08_P60_CL_STR-PRMNO sy-vline
WA_P08_P60_CL_STR-ECONR sy-vline
WA_P08_P60_CL_STR-WTEXT sy-vline
WA_P08_P60_CL_STR-PERID sy-vline
WA_P08_P60_CL_STR-ACTVE sy-vline
WA_P08_P60_CL_STR-ENAME sy-vline
WA_P08_P60_CL_STR-NACHN sy-vline
WA_P08_P60_CL_STR-VORNA sy-vline
WA_P08_P60_CL_STR-MIDNM sy-vline
WA_P08_P60_CL_STR-GBDAT sy-vline
WA_P08_P60_CL_STR-GESCH sy-vline
WA_P08_P60_CL_STR-LINE0 sy-vline
WA_P08_P60_CL_STR-LINE1 sy-vline
WA_P08_P60_CL_STR-LINE2 sy-vline
WA_P08_P60_CL_STR-LINE3 sy-vline
WA_P08_P60_CL_STR-PSTLZ sy-vline
WA_P08_P60_CL_STR-LAND1 sy-vline
WA_P08_P60_CL_STR-TXCOD sy-vline
WA_P08_P60_CL_STR-M1W1I sy-vline
WA_P08_P60_CL_STR-WEEK53 sy-vline
WA_P08_P60_CL_STR-STARTD sy-vline
WA_P08_P60_CL_STR-LEAVED sy-vline
WA_P08_P60_CL_STR-BEGDA sy-vline
WA_P08_P60_CL_STR-ENDDA sy-vline
WA_P08_P60_CL_STR-PENID sy-vline
WA_P08_P60_CL_STR-DIRID sy-vline
WA_P08_P60_CL_STR-TREFI sy-vline
WA_P08_P60_CL_STR-SUREF sy-vline
WA_P08_P60_CL_STR-TAXYR sy-vline
WA_P08_P60_CL_STR-ERADD sy-vline
WA_P08_P60_CL_STR-LINE0_2 sy-vline
WA_P08_P60_CL_STR-LINE1_2 sy-vline
WA_P08_P60_CL_STR-LINE2_2 sy-vline
WA_P08_P60_CL_STR-LINE3_2 sy-vline
WA_P08_P60_CL_STR-PSTLZ_2 sy-vline
WA_P08_P60_CL_STR-EMAIL sy-vline
WA_P08_P60_CL_STR-EMAIL_ID sy-vline
WA_P08_P60_CL_STR-WRKNO_P60 sy-vline
WA_P08_P60_CL_STR-NICAT sy-vline
WA_P08_P60_CL_STR-CTOUT sy-vline
WA_P08_P60_CL_STR-AMTTOLEL sy-vline
WA_P08_P60_CL_STR-AMTLELEET sy-vline
WA_P08_P60_CL_STR-AMTEETERT sy-vline
WA_P08_P60_CL_STR-AMTERTUEL sy-vline
WA_P08_P60_CL_STR-AMTFROMUEL sy-vline
WA_P08_P60_CL_STR-EENIC sy-vline
WA_P08_P60_CL_STR-ERNIC sy-vline
WA_P08_P60_CL_STR-EENIR sy-vline
WA_P08_P60_CL_STR-ERNIR sy-vline
WA_P08_P60_CL_STR-EEERS sy-vline
WA_P08_P60_CL_STR-NIREF sy-vline
WA_P08_P60_CL_STR-PSCON sy-vline
WA_P08_P60_CL_STR-AMTERTUAP sy-vline
WA_P08_P60_CL_STR-AMTLELPT sy-vline
WA_P08_P60_CL_STR-WIDOR sy-vline
WA_P08_P60_CL_STR-P_EARN sy-vline
WA_P08_P60_CL_STR-C_EARN sy-vline
WA_P08_P60_CL_STR-T_EARN sy-vline
WA_P08_P60_CL_STR-P_TAX sy-vline
WA_P08_P60_CL_STR-C_TAX sy-vline
WA_P08_P60_CL_STR-T_TAX sy-vline
WA_P08_P60_CL_STR-SLOAN sy-vline
WA_P08_P60_CL_STR-TCRED sy-vline
WA_P08_P60_CL_STR-SSPBT sy-vline
WA_P08_P60_CL_STR-SMPBT sy-vline
WA_P08_P60_CL_STR-SMPRC sy-vline
WA_P08_P60_CL_STR-NICRB sy-vline
WA_P08_P60_CL_STR-NIRTO sy-vline
WA_P08_P60_CL_STR-SUPER sy-vline
WA_P08_P60_CL_STR-TOGRP sy-vline
WA_P08_P60_CL_STR-SPPBT sy-vline
WA_P08_P60_CL_STR-RCSPP sy-vline
WA_P08_P60_CL_STR-SAPBT sy-vline
WA_P08_P60_CL_STR-RCSAP sy-vline
WA_P08_P60_CL_STR-ASPBT sy-vline
WA_P08_P60_CL_STR-RCASP sy-vline
WA_P08_P60_CL_STR-PLOAN sy-vline
WA_P08_P60_CL_STR-SBPYD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.