ABAP Select data from SAP table P08_P35_VER3 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P08_P35_VER3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P08_P35_VER3. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P08_P35_VER3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P08_P35_VER3 TYPE STANDARD TABLE OF P08_P35_VER3,
      WA_P08_P35_VER3 TYPE P08_P35_VER3,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P08_P35_VER3> TYPE P08_P35_VER3.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P08_P35_VER3.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P08_P35_VER3
  INTO TABLE IT_P08_P35_VER3.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P08_P35_VER3
*  INTO TABLE @DATA(IT_P08_P35_VER32).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P08_P35_VER3 INDEX 1 INTO DATA(WA_P08_P35_VER32).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P08_P35_VER3 ASSIGNING <P08_P35_VER3>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P08_P35_VER3>-ER_NAME = 1.
<P08_P35_VER3>-ER_STRT = 1.
<P08_P35_VER3>-ER_PLZ = 1.
<P08_P35_VER3>-ER_CITY = 1.
<P08_P35_VER3>-ECONR = 1.
ENDLOOP.

LOOP AT IT_P08_P35_VER3 INTO WA_P08_P35_VER3.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P08_P35_VER3-TREFI, sy-vline,
WA_P08_P35_VER3-NIREF, sy-vline,
WA_P08_P35_VER3-CESSDATE, sy-vline,
WA_P08_P35_VER3-TONIC, sy-vline,
WA_P08_P35_VER3-RPMSP, sy-vline,
WA_P08_P35_VER3-SNIMS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P08_P35_VER3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P08_P35_VER3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P08_P35_VER3 INTO WA_P08_P35_VER3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P08_P35_VER3_STR,
ER_NAME TYPE STRING,
ER_STRT TYPE STRING,
ER_PLZ TYPE STRING,
ER_CITY TYPE STRING,
ECONR TYPE STRING,
TREFI TYPE STRING,
NIREF TYPE STRING,
CESSDATE TYPE STRING,
TONIC TYPE STRING,
RPMSP TYPE STRING,
SNIMS TYPE STRING,
RCSSP TYPE STRING,
RCSMP TYPE STRING,
NCSMP TYPE STRING,
RCSPP TYPE STRING,
NCSPP TYPE STRING,
RCSAP TYPE STRING,
NCSAP TYPE STRING,
NHCLM TYPE STRING,
NIRCL TYPE STRING,
SRECC TYPE STRING,
DPYRE TYPE STRING,
TOTAX TYPE STRING,
TAXRE TYPE STRING,
TAXSU TYPE STRING,
TAXST TYPE STRING,
TTANI TYPE STRING,
TSTLO TYPE STRING,
STOTL TYPE STRING,
TCRFU TYPE STRING,
TCRTO TYPE STRING,
SGTOT TYPE STRING,
REDTO TYPE STRING,
TTCRE TYPE STRING,
DAMPY TYPE STRING,
TXNPD TYPE STRING,
INCPY TYPE STRING,
DPNOW TYPE STRING,
CISDE TYPE STRING,
NOWRV TYPE STRING,
P14CO TYPE STRING,
P38CO TYPE STRING,
P38SC TYPE STRING,
COLSR TYPE STRING,
RCASP TYPE STRING,
NCASP TYPE STRING,
P14ONLY TYPE STRING,
FREETAX TYPE STRING,
EXPENSE TYPE STRING,
OUTOFUK TYPE STRING,
OUKISIN TYPE STRING,
PAYTOTP TYPE STRING,
PTTISIN TYPE STRING,
IR35PAY TYPE STRING,
SPISIN TYPE STRING,
P14DEC TYPE STRING,
P38ADEC TYPE STRING,
P46HELD TYPE STRING,
P38ACOM TYPE STRING,
P11DDEC TYPE STRING,
P9DDEC TYPE STRING,END OF T_EKKO_STR. DATA: WA_P08_P35_VER3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P08_P35_VER3_STR-ER_NAME sy-vline
WA_P08_P35_VER3_STR-ER_STRT sy-vline
WA_P08_P35_VER3_STR-ER_PLZ sy-vline
WA_P08_P35_VER3_STR-ER_CITY sy-vline
WA_P08_P35_VER3_STR-ECONR sy-vline
WA_P08_P35_VER3_STR-TREFI sy-vline
WA_P08_P35_VER3_STR-NIREF sy-vline
WA_P08_P35_VER3_STR-CESSDATE sy-vline
WA_P08_P35_VER3_STR-TONIC sy-vline
WA_P08_P35_VER3_STR-RPMSP sy-vline
WA_P08_P35_VER3_STR-SNIMS sy-vline
WA_P08_P35_VER3_STR-RCSSP sy-vline
WA_P08_P35_VER3_STR-RCSMP sy-vline
WA_P08_P35_VER3_STR-NCSMP sy-vline
WA_P08_P35_VER3_STR-RCSPP sy-vline
WA_P08_P35_VER3_STR-NCSPP sy-vline
WA_P08_P35_VER3_STR-RCSAP sy-vline
WA_P08_P35_VER3_STR-NCSAP sy-vline
WA_P08_P35_VER3_STR-NHCLM sy-vline
WA_P08_P35_VER3_STR-NIRCL sy-vline
WA_P08_P35_VER3_STR-SRECC sy-vline
WA_P08_P35_VER3_STR-DPYRE sy-vline
WA_P08_P35_VER3_STR-TOTAX sy-vline
WA_P08_P35_VER3_STR-TAXRE sy-vline
WA_P08_P35_VER3_STR-TAXSU sy-vline
WA_P08_P35_VER3_STR-TAXST sy-vline
WA_P08_P35_VER3_STR-TTANI sy-vline
WA_P08_P35_VER3_STR-TSTLO sy-vline
WA_P08_P35_VER3_STR-STOTL sy-vline
WA_P08_P35_VER3_STR-TCRFU sy-vline
WA_P08_P35_VER3_STR-TCRTO sy-vline
WA_P08_P35_VER3_STR-SGTOT sy-vline
WA_P08_P35_VER3_STR-REDTO sy-vline
WA_P08_P35_VER3_STR-TTCRE sy-vline
WA_P08_P35_VER3_STR-DAMPY sy-vline
WA_P08_P35_VER3_STR-TXNPD sy-vline
WA_P08_P35_VER3_STR-INCPY sy-vline
WA_P08_P35_VER3_STR-DPNOW sy-vline
WA_P08_P35_VER3_STR-CISDE sy-vline
WA_P08_P35_VER3_STR-NOWRV sy-vline
WA_P08_P35_VER3_STR-P14CO sy-vline
WA_P08_P35_VER3_STR-P38CO sy-vline
WA_P08_P35_VER3_STR-P38SC sy-vline
WA_P08_P35_VER3_STR-COLSR sy-vline
WA_P08_P35_VER3_STR-RCASP sy-vline
WA_P08_P35_VER3_STR-NCASP sy-vline
WA_P08_P35_VER3_STR-P14ONLY sy-vline
WA_P08_P35_VER3_STR-FREETAX sy-vline
WA_P08_P35_VER3_STR-EXPENSE sy-vline
WA_P08_P35_VER3_STR-OUTOFUK sy-vline
WA_P08_P35_VER3_STR-OUKISIN sy-vline
WA_P08_P35_VER3_STR-PAYTOTP sy-vline
WA_P08_P35_VER3_STR-PTTISIN sy-vline
WA_P08_P35_VER3_STR-IR35PAY sy-vline
WA_P08_P35_VER3_STR-SPISIN sy-vline
WA_P08_P35_VER3_STR-P14DEC sy-vline
WA_P08_P35_VER3_STR-P38ADEC sy-vline
WA_P08_P35_VER3_STR-P46HELD sy-vline
WA_P08_P35_VER3_STR-P38ACOM sy-vline
WA_P08_P35_VER3_STR-P11DDEC sy-vline
WA_P08_P35_VER3_STR-P9DDEC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.