ABAP Select data from SAP table P08_P35_C_VER2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P08_P35_C_VER2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P08_P35_C_VER2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P08_P35_C_VER2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P08_P35_C_VER2 TYPE STANDARD TABLE OF P08_P35_C_VER2,
      WA_P08_P35_C_VER2 TYPE P08_P35_C_VER2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P08_P35_C_VER2> TYPE P08_P35_C_VER2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P08_P35_C_VER2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P08_P35_C_VER2
  INTO TABLE IT_P08_P35_C_VER2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P08_P35_C_VER2
*  INTO TABLE @DATA(IT_P08_P35_C_VER22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P08_P35_C_VER2 INDEX 1 INTO DATA(WA_P08_P35_C_VER22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P08_P35_C_VER2 ASSIGNING <P08_P35_C_VER2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P08_P35_C_VER2>-ER_NAME = 1.
<P08_P35_C_VER2>-ER_STRT = 1.
<P08_P35_C_VER2>-ER_PLZ = 1.
<P08_P35_C_VER2>-ER_CITY = 1.
<P08_P35_C_VER2>-ECONR = 1.
ENDLOOP.

LOOP AT IT_P08_P35_C_VER2 INTO WA_P08_P35_C_VER2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P08_P35_C_VER2-TREFI, sy-vline,
WA_P08_P35_C_VER2-NIREF, sy-vline,
WA_P08_P35_C_VER2-CESSDATE, sy-vline,
WA_P08_P35_C_VER2-TONIC, sy-vline,
WA_P08_P35_C_VER2-RPMSP, sy-vline,
WA_P08_P35_C_VER2-SNIMS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P08_P35_C_VER2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P08_P35_C_VER2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P08_P35_C_VER2 INTO WA_P08_P35_C_VER2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P08_P35_C_VER2_STR,
ER_NAME TYPE STRING,
ER_STRT TYPE STRING,
ER_PLZ TYPE STRING,
ER_CITY TYPE STRING,
ECONR TYPE STRING,
TREFI TYPE STRING,
NIREF TYPE STRING,
CESSDATE TYPE STRING,
TONIC TYPE STRING,
RPMSP TYPE STRING,
SNIMS TYPE STRING,
RCSSP TYPE STRING,
RCSMP TYPE STRING,
NCSMP TYPE STRING,
RCSPP TYPE STRING,
NCSPP TYPE STRING,
RCSAP TYPE STRING,
NCSAP TYPE STRING,
NHCLM TYPE STRING,
NIRCL TYPE STRING,
SRECC TYPE STRING,
DPYRE TYPE STRING,
TOTAX TYPE STRING,
TAXRE TYPE STRING,
TAXSU TYPE STRING,
TAXST TYPE STRING,
TTANI TYPE STRING,
TSTLO TYPE STRING,
STOTL TYPE STRING,
TCRFU TYPE STRING,
TCRTO TYPE STRING,
SGTOT TYPE STRING,
REDTO TYPE STRING,
TTCRE TYPE STRING,
DAMPY TYPE STRING,
TXNPD TYPE STRING,
INCPY TYPE STRING,
DPNOW TYPE STRING,
CISDE TYPE STRING,
NOWRV TYPE STRING,
P14CO TYPE STRING,
P38CO TYPE STRING,
P38SC TYPE STRING,
COLSR TYPE STRING,
RCASP TYPE STRING,
NCASP TYPE STRING,END OF T_EKKO_STR. DATA: WA_P08_P35_C_VER2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P08_P35_C_VER2_STR-ER_NAME sy-vline
WA_P08_P35_C_VER2_STR-ER_STRT sy-vline
WA_P08_P35_C_VER2_STR-ER_PLZ sy-vline
WA_P08_P35_C_VER2_STR-ER_CITY sy-vline
WA_P08_P35_C_VER2_STR-ECONR sy-vline
WA_P08_P35_C_VER2_STR-TREFI sy-vline
WA_P08_P35_C_VER2_STR-NIREF sy-vline
WA_P08_P35_C_VER2_STR-CESSDATE sy-vline
WA_P08_P35_C_VER2_STR-TONIC sy-vline
WA_P08_P35_C_VER2_STR-RPMSP sy-vline
WA_P08_P35_C_VER2_STR-SNIMS sy-vline
WA_P08_P35_C_VER2_STR-RCSSP sy-vline
WA_P08_P35_C_VER2_STR-RCSMP sy-vline
WA_P08_P35_C_VER2_STR-NCSMP sy-vline
WA_P08_P35_C_VER2_STR-RCSPP sy-vline
WA_P08_P35_C_VER2_STR-NCSPP sy-vline
WA_P08_P35_C_VER2_STR-RCSAP sy-vline
WA_P08_P35_C_VER2_STR-NCSAP sy-vline
WA_P08_P35_C_VER2_STR-NHCLM sy-vline
WA_P08_P35_C_VER2_STR-NIRCL sy-vline
WA_P08_P35_C_VER2_STR-SRECC sy-vline
WA_P08_P35_C_VER2_STR-DPYRE sy-vline
WA_P08_P35_C_VER2_STR-TOTAX sy-vline
WA_P08_P35_C_VER2_STR-TAXRE sy-vline
WA_P08_P35_C_VER2_STR-TAXSU sy-vline
WA_P08_P35_C_VER2_STR-TAXST sy-vline
WA_P08_P35_C_VER2_STR-TTANI sy-vline
WA_P08_P35_C_VER2_STR-TSTLO sy-vline
WA_P08_P35_C_VER2_STR-STOTL sy-vline
WA_P08_P35_C_VER2_STR-TCRFU sy-vline
WA_P08_P35_C_VER2_STR-TCRTO sy-vline
WA_P08_P35_C_VER2_STR-SGTOT sy-vline
WA_P08_P35_C_VER2_STR-REDTO sy-vline
WA_P08_P35_C_VER2_STR-TTCRE sy-vline
WA_P08_P35_C_VER2_STR-DAMPY sy-vline
WA_P08_P35_C_VER2_STR-TXNPD sy-vline
WA_P08_P35_C_VER2_STR-INCPY sy-vline
WA_P08_P35_C_VER2_STR-DPNOW sy-vline
WA_P08_P35_C_VER2_STR-CISDE sy-vline
WA_P08_P35_C_VER2_STR-NOWRV sy-vline
WA_P08_P35_C_VER2_STR-P14CO sy-vline
WA_P08_P35_C_VER2_STR-P38CO sy-vline
WA_P08_P35_C_VER2_STR-P38SC sy-vline
WA_P08_P35_C_VER2_STR-COLSR sy-vline
WA_P08_P35_C_VER2_STR-RCASP sy-vline
WA_P08_P35_C_VER2_STR-NCASP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.