ABAP Select data from SAP table P08_LGPS_EE_CONTRIBUTIONS_NEW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P08_LGPS_EE_CONTRIBUTIONS_NEW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P08_LGPS_EE_CONTRIBUTIONS_NEW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P08_LGPS_EE_CONTRIBUTIONS_NEW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P08_LGPS_EE_CONTRIBUTIONS_NEW TYPE STANDARD TABLE OF P08_LGPS_EE_CONTRIBUTIONS_NEW,
      WA_P08_LGPS_EE_CONTRIBUTIONS_NEW TYPE P08_LGPS_EE_CONTRIBUTIONS_NEW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P08_LGPS_EE_CONTRIBUTIONS_NEW> TYPE P08_LGPS_EE_CONTRIBUTIONS_NEW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P08_LGPS_EE_CONTRIBUTIONS_NEW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P08_LGPS_EE_CONTRIBUTIONS_NEW
  INTO TABLE IT_P08_LGPS_EE_CONTRIBUTIONS_NEW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P08_LGPS_EE_CONTRIBUTIONS_NEW
*  INTO TABLE @DATA(IT_P08_LGPS_EE_CONTRIBUTIONS_NEW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P08_LGPS_EE_CONTRIBUTIONS_NEW INDEX 1 INTO DATA(WA_P08_LGPS_EE_CONTRIBUTIONS_NEW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P08_LGPS_EE_CONTRIBUTIONS_NEW ASSIGNING <P08_LGPS_EE_CONTRIBUTIONS_NEW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P08_LGPS_EE_CONTRIBUTIONS_NEW>-ENAME = 1.
<P08_LGPS_EE_CONTRIBUTIONS_NEW>-DATUM = 1.
<P08_LGPS_EE_CONTRIBUTIONS_NEW>-NINO = 1.
<P08_LGPS_EE_CONTRIBUTIONS_NEW>-SEQNR = 1.
<P08_LGPS_EE_CONTRIBUTIONS_NEW>-SRTZA = 1.
ENDLOOP.

LOOP AT IT_P08_LGPS_EE_CONTRIBUTIONS_NEW INTO WA_P08_LGPS_EE_CONTRIBUTIONS_NEW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P08_LGPS_EE_CONTRIBUTIONS_NEW-FPPER, sy-vline,
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW-FPBEG, sy-vline,
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW-FPEND, sy-vline,
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW-IABKRS, sy-vline,
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW-INPER, sy-vline,
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW-SCHID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P08_LGPS_EE_CONTRIBUTIONS_NEW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P08_LGPS_EE_CONTRIBUTIONS_NEW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P08_LGPS_EE_CONTRIBUTIONS_NEW INTO WA_P08_LGPS_EE_CONTRIBUTIONS_NEW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR,
ENAME TYPE STRING,
DATUM TYPE STRING,
NINO TYPE STRING,
SEQNR TYPE STRING,
SRTZA TYPE STRING,
FPPER TYPE STRING,
FPBEG TYPE STRING,
FPEND TYPE STRING,
IABKRS TYPE STRING,
INPER TYPE STRING,
SCHID TYPE STRING,
PCTEE TYPE STRING,
GRSEE TYPE STRING,
CNTEE TYPE STRING,
PCTER TYPE STRING,
GRSER TYPE STRING,
CNTER TYPE STRING,END OF T_EKKO_STR. DATA: WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-ENAME sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-DATUM sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-NINO sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-SEQNR sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-SRTZA sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-FPPER sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-FPBEG sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-FPEND sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-IABKRS sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-INPER sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-SCHID sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-PCTEE sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-GRSEE sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-CNTEE sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-PCTER sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-GRSER sy-vline
WA_P08_LGPS_EE_CONTRIBUTIONS_NEW_STR-CNTER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.