ABAP Select data from SAP table P0782 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P0782 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P0782. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P0782 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P0782 TYPE STANDARD TABLE OF P0782,
      WA_P0782 TYPE P0782,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P0782> TYPE P0782.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P0782.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P0782
  INTO TABLE IT_P0782.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P0782
*  INTO TABLE @DATA(IT_P07822).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P0782 INDEX 1 INTO DATA(WA_P07822).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P0782 ASSIGNING <P0782>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P0782>-PERNR = 1.
<P0782>-INFTY = 1.
<P0782>-SUBTY = 1.
<P0782>-OBJPS = 1.
<P0782>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_P0782 INTO WA_P0782.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P0782-ENDDA, sy-vline,
WA_P0782-BEGDA, sy-vline,
WA_P0782-SEQNR, sy-vline,
WA_P0782-AEDTM, sy-vline,
WA_P0782-UNAME, sy-vline,
WA_P0782-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P0782 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P0782 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P0782 INTO WA_P0782. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ADRBEH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P0782-ADRBEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P0782-ADRBEH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P0782_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
ADRBEH TYPE STRING,
PNRAVES TYPE STRING,
PNRAVAB TYPE STRING,
BRART TYPE STRING,
VSART TYPE STRING,
VEBEZ TYPE STRING,
VBWAE TYPE STRING,
SOZUW TYPE STRING,
SZWAE TYPE STRING,
UNTB TYPE STRING,
UNWAE TYPE STRING,
ZP50 TYPE STRING,
ZP50WAE TYPE STRING,
HGP54 TYPE STRING,
VHSAB TYPE STRING,
AUNTB TYPE STRING,
AUWAE TYPE STRING,
NABRE TYPE STRING,
AAKHGSB TYPE STRING,
SBETRG_KINDER TYPE STRING,
SBETRG_KINDER_WA TYPE STRING,
ZUSTZL_BETRG_HG TYPE STRING,
ZUS_BETRG_HG_WA TYPE STRING,
RUHENS_P55 TYPE STRING,
RUHENS_P55_WA TYPE STRING,
AUSGLEICH TYPE STRING,
AUSGLEICH_WA TYPE STRING,
HAERTE_P55 TYPE STRING,
HAERTE_P55_WA TYPE STRING,
FLAG_UNFALLVERS TYPE STRING,
SOZA_O_UNTB TYPE STRING,
SOZA_O_UNTB_WA TYPE STRING,
VHS_AUFSCHL TYPE STRING,
VERS_AUSGLEICH TYPE STRING,
VERS_AUSGLEICH_W TYPE STRING,
ABZUG_P50F TYPE STRING,
ABZUG_P50F_WA TYPE STRING,END OF T_EKKO_STR. DATA: WA_P0782_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P0782_STR-PERNR sy-vline
WA_P0782_STR-INFTY sy-vline
WA_P0782_STR-SUBTY sy-vline
WA_P0782_STR-OBJPS sy-vline
WA_P0782_STR-SPRPS sy-vline
WA_P0782_STR-ENDDA sy-vline
WA_P0782_STR-BEGDA sy-vline
WA_P0782_STR-SEQNR sy-vline
WA_P0782_STR-AEDTM sy-vline
WA_P0782_STR-UNAME sy-vline
WA_P0782_STR-HISTO sy-vline
WA_P0782_STR-ITXEX sy-vline
WA_P0782_STR-REFEX sy-vline
WA_P0782_STR-ORDEX sy-vline
WA_P0782_STR-ITBLD sy-vline
WA_P0782_STR-PREAS sy-vline
WA_P0782_STR-FLAG1 sy-vline
WA_P0782_STR-FLAG2 sy-vline
WA_P0782_STR-FLAG3 sy-vline
WA_P0782_STR-FLAG4 sy-vline
WA_P0782_STR-RESE1 sy-vline
WA_P0782_STR-RESE2 sy-vline
WA_P0782_STR-GRPVL sy-vline
WA_P0782_STR-ADRBEH sy-vline
WA_P0782_STR-PNRAVES sy-vline
WA_P0782_STR-PNRAVAB sy-vline
WA_P0782_STR-BRART sy-vline
WA_P0782_STR-VSART sy-vline
WA_P0782_STR-VEBEZ sy-vline
WA_P0782_STR-VBWAE sy-vline
WA_P0782_STR-SOZUW sy-vline
WA_P0782_STR-SZWAE sy-vline
WA_P0782_STR-UNTB sy-vline
WA_P0782_STR-UNWAE sy-vline
WA_P0782_STR-ZP50 sy-vline
WA_P0782_STR-ZP50WAE sy-vline
WA_P0782_STR-HGP54 sy-vline
WA_P0782_STR-VHSAB sy-vline
WA_P0782_STR-AUNTB sy-vline
WA_P0782_STR-AUWAE sy-vline
WA_P0782_STR-NABRE sy-vline
WA_P0782_STR-AAKHGSB sy-vline
WA_P0782_STR-SBETRG_KINDER sy-vline
WA_P0782_STR-SBETRG_KINDER_WA sy-vline
WA_P0782_STR-ZUSTZL_BETRG_HG sy-vline
WA_P0782_STR-ZUS_BETRG_HG_WA sy-vline
WA_P0782_STR-RUHENS_P55 sy-vline
WA_P0782_STR-RUHENS_P55_WA sy-vline
WA_P0782_STR-AUSGLEICH sy-vline
WA_P0782_STR-AUSGLEICH_WA sy-vline
WA_P0782_STR-HAERTE_P55 sy-vline
WA_P0782_STR-HAERTE_P55_WA sy-vline
WA_P0782_STR-FLAG_UNFALLVERS sy-vline
WA_P0782_STR-SOZA_O_UNTB sy-vline
WA_P0782_STR-SOZA_O_UNTB_WA sy-vline
WA_P0782_STR-VHS_AUFSCHL sy-vline
WA_P0782_STR-VERS_AUSGLEICH sy-vline
WA_P0782_STR-VERS_AUSGLEICH_W sy-vline
WA_P0782_STR-ABZUG_P50F sy-vline
WA_P0782_STR-ABZUG_P50F_WA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.