ABAP Select data from SAP table P06P_TG_LR_T_MVT02 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P06P_TG_LR_T_MVT02 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P06P_TG_LR_T_MVT02. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P06P_TG_LR_T_MVT02 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P06P_TG_LR_T_MVT02 TYPE STANDARD TABLE OF P06P_TG_LR_T_MVT02,
      WA_P06P_TG_LR_T_MVT02 TYPE P06P_TG_LR_T_MVT02,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P06P_TG_LR_T_MVT02> TYPE P06P_TG_LR_T_MVT02.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P06P_TG_LR_T_MVT02.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P06P_TG_LR_T_MVT02
  INTO TABLE IT_P06P_TG_LR_T_MVT02.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P06P_TG_LR_T_MVT02
*  INTO TABLE @DATA(IT_P06P_TG_LR_T_MVT022).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P06P_TG_LR_T_MVT02 INDEX 1 INTO DATA(WA_P06P_TG_LR_T_MVT022).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P06P_TG_LR_T_MVT02 ASSIGNING <P06P_TG_LR_T_MVT02>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P06P_TG_LR_T_MVT02>-SECTN = 1.
<P06P_TG_LR_T_MVT02>-DATEF = 1.
<P06P_TG_LR_T_MVT02>-IFSVC = 1.
<P06P_TG_LR_T_MVT02>-SUPFA = 1.
<P06P_TG_LR_T_MVT02>-BLC04 = 1.
ENDLOOP.

LOOP AT IT_P06P_TG_LR_T_MVT02 INTO WA_P06P_TG_LR_T_MVT02.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P06P_TG_LR_T_MVT02-CRESS, sy-vline,
WA_P06P_TG_LR_T_MVT02-BLC1A, sy-vline,
WA_P06P_TG_LR_T_MVT02-CMUT4, sy-vline,
WA_P06P_TG_LR_T_MVT02-CRETC, sy-vline,
WA_P06P_TG_LR_T_MVT02-REREM, sy-vline,
WA_P06P_TG_LR_T_MVT02-CSTAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P06P_TG_LR_T_MVT02 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P06P_TG_LR_T_MVT02 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P06P_TG_LR_T_MVT02 INTO WA_P06P_TG_LR_T_MVT02. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P06P_TG_LR_T_MVT02_STR,
SECTN TYPE STRING,
DATEF TYPE STRING,
IFSVC TYPE STRING,
SUPFA TYPE STRING,
BLC04 TYPE STRING,
CRESS TYPE STRING,
BLC1A TYPE STRING,
CMUT4 TYPE STRING,
CRETC TYPE STRING,
REREM TYPE STRING,
CSTAT TYPE STRING,
VBDGT TYPE STRING,
IPCIV TYPE STRING,
CFINS TYPE STRING,
DFINS TYPE STRING,
BLC1B TYPE STRING,
IBONI TYPE STRING,
BLC19 TYPE STRING,
CDETA TYPE STRING,END OF T_EKKO_STR. DATA: WA_P06P_TG_LR_T_MVT02_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P06P_TG_LR_T_MVT02_STR-SECTN sy-vline
WA_P06P_TG_LR_T_MVT02_STR-DATEF sy-vline
WA_P06P_TG_LR_T_MVT02_STR-IFSVC sy-vline
WA_P06P_TG_LR_T_MVT02_STR-SUPFA sy-vline
WA_P06P_TG_LR_T_MVT02_STR-BLC04 sy-vline
WA_P06P_TG_LR_T_MVT02_STR-CRESS sy-vline
WA_P06P_TG_LR_T_MVT02_STR-BLC1A sy-vline
WA_P06P_TG_LR_T_MVT02_STR-CMUT4 sy-vline
WA_P06P_TG_LR_T_MVT02_STR-CRETC sy-vline
WA_P06P_TG_LR_T_MVT02_STR-REREM sy-vline
WA_P06P_TG_LR_T_MVT02_STR-CSTAT sy-vline
WA_P06P_TG_LR_T_MVT02_STR-VBDGT sy-vline
WA_P06P_TG_LR_T_MVT02_STR-IPCIV sy-vline
WA_P06P_TG_LR_T_MVT02_STR-CFINS sy-vline
WA_P06P_TG_LR_T_MVT02_STR-DFINS sy-vline
WA_P06P_TG_LR_T_MVT02_STR-BLC1B sy-vline
WA_P06P_TG_LR_T_MVT02_STR-IBONI sy-vline
WA_P06P_TG_LR_T_MVT02_STR-BLC19 sy-vline
WA_P06P_TG_LR_T_MVT02_STR-CDETA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.