ABAP Select data from SAP table P06P_TG_GS_T_MVT9J into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P06P_TG_GS_T_MVT9J table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P06P_TG_GS_T_MVT9J. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P06P_TG_GS_T_MVT9J table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P06P_TG_GS_T_MVT9J TYPE STANDARD TABLE OF P06P_TG_GS_T_MVT9J,
      WA_P06P_TG_GS_T_MVT9J TYPE P06P_TG_GS_T_MVT9J,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P06P_TG_GS_T_MVT9J> TYPE P06P_TG_GS_T_MVT9J.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P06P_TG_GS_T_MVT9J.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P06P_TG_GS_T_MVT9J
  INTO TABLE IT_P06P_TG_GS_T_MVT9J.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P06P_TG_GS_T_MVT9J
*  INTO TABLE @DATA(IT_P06P_TG_GS_T_MVT9J2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P06P_TG_GS_T_MVT9J INDEX 1 INTO DATA(WA_P06P_TG_GS_T_MVT9J2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P06P_TG_GS_T_MVT9J ASSIGNING <P06P_TG_GS_T_MVT9J>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P06P_TG_GS_T_MVT9J>-SECTN = 1.
<P06P_TG_GS_T_MVT9J>-TYM9J = 1.
<P06P_TG_GS_T_MVT9J>-CODGJ = 1.
<P06P_TG_GS_T_MVT9J>-DEPGE = 1.
<P06P_TG_GS_T_MVT9J>-BLC07 = 1.
ENDLOOP.

LOOP AT IT_P06P_TG_GS_T_MVT9J INTO WA_P06P_TG_GS_T_MVT9J.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P06P_TG_GS_T_MVT9J-DANAI, sy-vline,
WA_P06P_TG_GS_T_MVT9J-POSEN, sy-vline,
WA_P06P_TG_GS_T_MVT9J-DAFER, sy-vline,
WA_P06P_TG_GS_T_MVT9J-CODPR, sy-vline,
WA_P06P_TG_GS_T_MVT9J-DAFIN, sy-vline,
ENDLOOP. *Add any further fields from structure WA_P06P_TG_GS_T_MVT9J you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P06P_TG_GS_T_MVT9J TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P06P_TG_GS_T_MVT9J INTO WA_P06P_TG_GS_T_MVT9J. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PDATE, internal->external for field DANAI CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_P06P_TG_GS_T_MVT9J-DANAI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P06P_TG_GS_T_MVT9J-DANAI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P06P_TG_GS_T_MVT9J_STR,
SECTN TYPE STRING,
TYM9J TYPE STRING,
CODGJ TYPE STRING,
DEPGE TYPE STRING,
BLC07 TYPE STRING,
DANAI TYPE STRING,
POSEN TYPE STRING,
DAFER TYPE STRING,
CODPR TYPE STRING,
DAFIN TYPE STRING,END OF T_EKKO_STR. DATA: WA_P06P_TG_GS_T_MVT9J_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-SECTN sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-TYM9J sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-CODGJ sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-DEPGE sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-BLC07 sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-DANAI sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-POSEN sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-DAFER sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-CODPR sy-vline
WA_P06P_TG_GS_T_MVT9J_STR-DAFIN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.