ABAP Select data from SAP table P06DWNCRC300 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P06DWNCRC300 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P06DWNCRC300. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P06DWNCRC300 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P06DWNCRC300 TYPE STANDARD TABLE OF P06DWNCRC300,
      WA_P06DWNCRC300 TYPE P06DWNCRC300,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P06DWNCRC300> TYPE P06DWNCRC300.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P06DWNCRC300.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P06DWNCRC300
  INTO TABLE IT_P06DWNCRC300.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P06DWNCRC300
*  INTO TABLE @DATA(IT_P06DWNCRC3002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P06DWNCRC300 INDEX 1 INTO DATA(WA_P06DWNCRC3002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P06DWNCRC300 ASSIGNING <P06DWNCRC300>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P06DWNCRC300>-SIRET1 = 1.
<P06DWNCRC300>-ZERO = 1.
<P06DWNCRC300>-ANNEE = 1.
<P06DWNCRC300>-TYPDEC = 1.
<P06DWNCRC300>-TYPENREG = 1.
ENDLOOP.

LOOP AT IT_P06DWNCRC300 INTO WA_P06DWNCRC300.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P06DWNCRC300-TOTLINE, sy-vline,
WA_P06DWNCRC300-CODEASST, sy-vline,
WA_P06DWNCRC300-TOTSAL, sy-vline,
WA_P06DWNCRC300-CODEASSA, sy-vline,
WA_P06DWNCRC300-TOTTRANCHEA, sy-vline,
WA_P06DWNCRC300-CODEASSB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P06DWNCRC300 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P06DWNCRC300 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P06DWNCRC300 INTO WA_P06DWNCRC300. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P06DWNCRC300_STR,
SIRET1 TYPE STRING,
ZERO TYPE STRING,
ANNEE TYPE STRING,
TYPDEC TYPE STRING,
TYPENREG TYPE STRING,
TOTLINE TYPE STRING,
CODEASST TYPE STRING,
TOTSAL TYPE STRING,
CODEASSA TYPE STRING,
TOTTRANCHEA TYPE STRING,
CODEASSB TYPE STRING,
TOTTRANCHEB TYPE STRING,
CODEASSC TYPE STRING,
TOTTRANCHEC TYPE STRING,
CODEASSS TYPE STRING,
TOTSOMISOL TYPE STRING,
CODEASSD TYPE STRING,
TOTSALREC TYPE STRING,
CODEASSE TYPE STRING,
TOTASSFORF TYPE STRING,
CODEASSFK TYPE STRING,
TOTAVENANT TYPE STRING,
CODEASSU TYPE STRING,
TOTINDPREV TYPE STRING,
RESER153 TYPE STRING,
NOMSIG TYPE STRING,
PRENOMSIG TYPE STRING,
DIVERS TYPE STRING,
RESER131 TYPE STRING,
DEBUT TYPE STRING,
FIN TYPE STRING,
IDENTI TYPE STRING,
NUMINS TYPE STRING,
IDENTE TYPE STRING,END OF T_EKKO_STR. DATA: WA_P06DWNCRC300_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P06DWNCRC300_STR-SIRET1 sy-vline
WA_P06DWNCRC300_STR-ZERO sy-vline
WA_P06DWNCRC300_STR-ANNEE sy-vline
WA_P06DWNCRC300_STR-TYPDEC sy-vline
WA_P06DWNCRC300_STR-TYPENREG sy-vline
WA_P06DWNCRC300_STR-TOTLINE sy-vline
WA_P06DWNCRC300_STR-CODEASST sy-vline
WA_P06DWNCRC300_STR-TOTSAL sy-vline
WA_P06DWNCRC300_STR-CODEASSA sy-vline
WA_P06DWNCRC300_STR-TOTTRANCHEA sy-vline
WA_P06DWNCRC300_STR-CODEASSB sy-vline
WA_P06DWNCRC300_STR-TOTTRANCHEB sy-vline
WA_P06DWNCRC300_STR-CODEASSC sy-vline
WA_P06DWNCRC300_STR-TOTTRANCHEC sy-vline
WA_P06DWNCRC300_STR-CODEASSS sy-vline
WA_P06DWNCRC300_STR-TOTSOMISOL sy-vline
WA_P06DWNCRC300_STR-CODEASSD sy-vline
WA_P06DWNCRC300_STR-TOTSALREC sy-vline
WA_P06DWNCRC300_STR-CODEASSE sy-vline
WA_P06DWNCRC300_STR-TOTASSFORF sy-vline
WA_P06DWNCRC300_STR-CODEASSFK sy-vline
WA_P06DWNCRC300_STR-TOTAVENANT sy-vline
WA_P06DWNCRC300_STR-CODEASSU sy-vline
WA_P06DWNCRC300_STR-TOTINDPREV sy-vline
WA_P06DWNCRC300_STR-RESER153 sy-vline
WA_P06DWNCRC300_STR-NOMSIG sy-vline
WA_P06DWNCRC300_STR-PRENOMSIG sy-vline
WA_P06DWNCRC300_STR-DIVERS sy-vline
WA_P06DWNCRC300_STR-RESER131 sy-vline
WA_P06DWNCRC300_STR-DEBUT sy-vline
WA_P06DWNCRC300_STR-FIN sy-vline
WA_P06DWNCRC300_STR-IDENTI sy-vline
WA_P06DWNCRC300_STR-NUMINS sy-vline
WA_P06DWNCRC300_STR-IDENTE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.