ABAP Select data from SAP table P06DAD_T_ELEMENTS_COTIS3 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P06DAD_T_ELEMENTS_COTIS3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P06DAD_T_ELEMENTS_COTIS3. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P06DAD_T_ELEMENTS_COTIS3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P06DAD_T_ELEMENTS_COTIS3 TYPE STANDARD TABLE OF P06DAD_T_ELEMENTS_COTIS3,
      WA_P06DAD_T_ELEMENTS_COTIS3 TYPE P06DAD_T_ELEMENTS_COTIS3,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P06DAD_T_ELEMENTS_COTIS3> TYPE P06DAD_T_ELEMENTS_COTIS3.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P06DAD_T_ELEMENTS_COTIS3.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P06DAD_T_ELEMENTS_COTIS3
  INTO TABLE IT_P06DAD_T_ELEMENTS_COTIS3.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P06DAD_T_ELEMENTS_COTIS3
*  INTO TABLE @DATA(IT_P06DAD_T_ELEMENTS_COTIS32).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P06DAD_T_ELEMENTS_COTIS3 INDEX 1 INTO DATA(WA_P06DAD_T_ELEMENTS_COTIS32).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P06DAD_T_ELEMENTS_COTIS3 ASSIGNING <P06DAD_T_ELEMENTS_COTIS3>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P06DAD_T_ELEMENTS_COTIS3>-SECTN = 1.
<P06DAD_T_ELEMENTS_COTIS3>-NUMIC = 1.
<P06DAD_T_ELEMENTS_COTIS3>-UGEST = 1.
<P06DAD_T_ELEMENTS_COTIS3>-PRBEG = 1.
<P06DAD_T_ELEMENTS_COTIS3>-PREND = 1.
ENDLOOP.

LOOP AT IT_P06DAD_T_ELEMENTS_COTIS3 INTO WA_P06DAD_T_ELEMENTS_COTIS3.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P06DAD_T_ELEMENTS_COTIS3-PCS, sy-vline,
WA_P06DAD_T_ELEMENTS_COTIS3-REFCT, sy-vline,
WA_P06DAD_T_ELEMENTS_COTIS3-DESTI, sy-vline,
WA_P06DAD_T_ELEMENTS_COTIS3-BSNAT, sy-vline,
WA_P06DAD_T_ELEMENTS_COTIS3-BSAMT, sy-vline,
WA_P06DAD_T_ELEMENTS_COTIS3-FORFT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P06DAD_T_ELEMENTS_COTIS3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P06DAD_T_ELEMENTS_COTIS3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P06DAD_T_ELEMENTS_COTIS3 INTO WA_P06DAD_T_ELEMENTS_COTIS3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P06DAD_T_ELEMENTS_COTIS3_STR,
SECTN TYPE STRING,
NUMIC TYPE STRING,
UGEST TYPE STRING,
PRBEG TYPE STRING,
PREND TYPE STRING,
PCS TYPE STRING,
REFCT TYPE STRING,
DESTI TYPE STRING,
BSNAT TYPE STRING,
BSAMT TYPE STRING,
FORFT TYPE STRING,
FAMST TYPE STRING,
RISKC TYPE STRING,
REGAS TYPE STRING,
REGTX TYPE STRING,
REGAM TYPE STRING,END OF T_EKKO_STR. DATA: WA_P06DAD_T_ELEMENTS_COTIS3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-SECTN sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-NUMIC sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-UGEST sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-PRBEG sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-PREND sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-PCS sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-REFCT sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-DESTI sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-BSNAT sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-BSAMT sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-FORFT sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-FAMST sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-RISKC sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-REGAS sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-REGTX sy-vline
WA_P06DAD_T_ELEMENTS_COTIS3_STR-REGAM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.