Below is a number of ABAP code snippets to demonstrate how to select data from SAP P06_EMET table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P06_EMET. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P06_EMET table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P06_EMET TYPE STANDARD TABLE OF P06_EMET,
      WA_P06_EMET TYPE P06_EMET,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P06_EMET> TYPE P06_EMET.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P06_EMET.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P06_EMET
  INTO TABLE IT_P06_EMET.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P06_EMET
*  INTO TABLE @DATA(IT_P06_EMET2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P06_EMET INDEX 1 INTO DATA(WA_P06_EMET2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P06_EMET ASSIGNING <P06_EMET>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P06_EMET>-EMSRN = 1.
<P06_EMET>-EMNIC = 1.
<P06_EMET>-EMRSN = 1.
<P06_EMET>-EMREF = 1.
<P06_EMET>-EMSFT = 1.
ENDLOOP.

LOOP AT IT_P06_EMET INTO WA_P06_EMET.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P06_EMET-EMEDT, sy-vline,
WA_P06_EMET-EMVSN, sy-vline,
WA_P06_EMET-EMCTL, sy-vline,
WA_P06_EMET-EMSRV, sy-vline,
WA_P06_EMET-EMENV, sy-vline,
WA_P06_EMET-EMNRM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P06_EMET you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P06_EMET TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P06_EMET INTO WA_P06_EMET. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P06_EMET_STR,
EMSRN TYPE STRING,
EMNIC TYPE STRING,
EMRSN TYPE STRING,
EMREF TYPE STRING,
EMSFT TYPE STRING,
EMEDT TYPE STRING,
EMVSN TYPE STRING,
EMCTL TYPE STRING,
EMSRV TYPE STRING,
EMENV TYPE STRING,
EMNRM TYPE STRING,
EMASC TYPE STRING,END OF T_EKKO_STR. DATA: WA_P06_EMET_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P06_EMET_STR-EMSRN sy-vline
WA_P06_EMET_STR-EMNIC sy-vline
WA_P06_EMET_STR-EMRSN sy-vline
WA_P06_EMET_STR-EMREF sy-vline
WA_P06_EMET_STR-EMSFT sy-vline
WA_P06_EMET_STR-EMEDT sy-vline
WA_P06_EMET_STR-EMVSN sy-vline
WA_P06_EMET_STR-EMCTL sy-vline
WA_P06_EMET_STR-EMSRV sy-vline
WA_P06_EMET_STR-EMENV sy-vline
WA_P06_EMET_STR-EMNRM sy-vline
WA_P06_EMET_STR-EMASC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.