ABAP Select data from SAP table P06_DSN_SPLIT_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP P06_DSN_SPLIT_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P06_DSN_SPLIT_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the P06_DSN_SPLIT_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_P06_DSN_SPLIT_DATA TYPE STANDARD TABLE OF P06_DSN_SPLIT_DATA,
WA_P06_DSN_SPLIT_DATA TYPE P06_DSN_SPLIT_DATA,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P06_DSN_SPLIT_DATA> TYPE P06_DSN_SPLIT_DATA.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_P06_DSN_SPLIT_DATA.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM P06_DSN_SPLIT_DATA
INTO TABLE IT_P06_DSN_SPLIT_DATA.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM P06_DSN_SPLIT_DATA
* INTO TABLE @DATA(IT_P06_DSN_SPLIT_DATA2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P06_DSN_SPLIT_DATA INDEX 1 INTO DATA(WA_P06_DSN_SPLIT_DATA2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P06_DSN_SPLIT_DATA ASSIGNING <P06_DSN_SPLIT_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<P06_DSN_SPLIT_DATA>-DENAT = 1.
<P06_DSN_SPLIT_DATA>-DETYP = 1.
<P06_DSN_SPLIT_DATA>-UIDCT = 1.
<P06_DSN_SPLIT_DATA>-NUMCT = 1.
<P06_DSN_SPLIT_DATA>-SIRET = 1.
ENDLOOP. LOOP AT IT_P06_DSN_SPLIT_DATA INTO WA_P06_DSN_SPLIT_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_P06_DSN_SPLIT_DATA-SIRET_OLD, sy-vline,
WA_P06_DSN_SPLIT_DATA-SIRET_TAB, sy-vline,
WA_P06_DSN_SPLIT_DATA-PERNR, sy-vline,
WA_P06_DSN_SPLIT_DATA-PERNR_OLD, sy-vline,
WA_P06_DSN_SPLIT_DATA-NBEMP_PROC, sy-vline,
WA_P06_DSN_SPLIT_DATA-NBDSN_MAX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P06_DSN_SPLIT_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P06_DSN_SPLIT_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P06_DSN_SPLIT_DATA INTO WA_P06_DSN_SPLIT_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P06_DSN_SPLIT_DATA_STR,
DENAT TYPE STRING,
DETYP TYPE STRING,
UIDCT TYPE STRING,
NUMCT TYPE STRING,
SIRET TYPE STRING,
SIRET_OLD TYPE STRING,
SIRET_TAB TYPE STRING,
PERNR TYPE STRING,
PERNR_OLD TYPE STRING,
NBEMP_PROC TYPE STRING,
NBDSN_MAX TYPE STRING,
NBDSN_PROC TYPE STRING,
SEQNO TYPE STRING,
PPROC TYPE STRING,
ARTR_KEY TYPE STRING,
NO_PAYROLL_RES TYPE STRING,END OF T_EKKO_STR. DATA: WA_P06_DSN_SPLIT_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P06_DSN_SPLIT_DATA_STR-DENAT sy-vline
WA_P06_DSN_SPLIT_DATA_STR-DETYP sy-vline
WA_P06_DSN_SPLIT_DATA_STR-UIDCT sy-vline
WA_P06_DSN_SPLIT_DATA_STR-NUMCT sy-vline
WA_P06_DSN_SPLIT_DATA_STR-SIRET sy-vline
WA_P06_DSN_SPLIT_DATA_STR-SIRET_OLD sy-vline
WA_P06_DSN_SPLIT_DATA_STR-SIRET_TAB sy-vline
WA_P06_DSN_SPLIT_DATA_STR-PERNR sy-vline
WA_P06_DSN_SPLIT_DATA_STR-PERNR_OLD sy-vline
WA_P06_DSN_SPLIT_DATA_STR-NBEMP_PROC sy-vline
WA_P06_DSN_SPLIT_DATA_STR-NBDSN_MAX sy-vline
WA_P06_DSN_SPLIT_DATA_STR-NBDSN_PROC sy-vline
WA_P06_DSN_SPLIT_DATA_STR-SEQNO sy-vline
WA_P06_DSN_SPLIT_DATA_STR-PPROC sy-vline
WA_P06_DSN_SPLIT_DATA_STR-ARTR_KEY sy-vline
WA_P06_DSN_SPLIT_DATA_STR-NO_PAYROLL_RES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.
