ABAP Select data from SAP table P05T_WCR_OVERVIEW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P05T_WCR_OVERVIEW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P05T_WCR_OVERVIEW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P05T_WCR_OVERVIEW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P05T_WCR_OVERVIEW TYPE STANDARD TABLE OF P05T_WCR_OVERVIEW,
      WA_P05T_WCR_OVERVIEW TYPE P05T_WCR_OVERVIEW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P05T_WCR_OVERVIEW> TYPE P05T_WCR_OVERVIEW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P05T_WCR_OVERVIEW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P05T_WCR_OVERVIEW
  INTO TABLE IT_P05T_WCR_OVERVIEW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P05T_WCR_OVERVIEW
*  INTO TABLE @DATA(IT_P05T_WCR_OVERVIEW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P05T_WCR_OVERVIEW INDEX 1 INTO DATA(WA_P05T_WCR_OVERVIEW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P05T_WCR_OVERVIEW ASSIGNING <P05T_WCR_OVERVIEW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P05T_WCR_OVERVIEW>-HEADER = 1.
<P05T_WCR_OVERVIEW>-TYPE = 1.
<P05T_WCR_OVERVIEW>-CODE = 1.
<P05T_WCR_OVERVIEW>-CURR = 1.
<P05T_WCR_OVERVIEW>-PER01 = 1.
ENDLOOP.

LOOP AT IT_P05T_WCR_OVERVIEW INTO WA_P05T_WCR_OVERVIEW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P05T_WCR_OVERVIEW-WAERS01, sy-vline,
WA_P05T_WCR_OVERVIEW-PER02, sy-vline,
WA_P05T_WCR_OVERVIEW-WAERS02, sy-vline,
WA_P05T_WCR_OVERVIEW-PER03, sy-vline,
WA_P05T_WCR_OVERVIEW-WAERS03, sy-vline,
WA_P05T_WCR_OVERVIEW-PER04, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P05T_WCR_OVERVIEW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P05T_WCR_OVERVIEW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P05T_WCR_OVERVIEW INTO WA_P05T_WCR_OVERVIEW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P05T_WCR_OVERVIEW_STR,
HEADER TYPE STRING,
TYPE TYPE STRING,
CODE TYPE STRING,
CURR TYPE STRING,
PER01 TYPE STRING,
WAERS01 TYPE STRING,
PER02 TYPE STRING,
WAERS02 TYPE STRING,
PER03 TYPE STRING,
WAERS03 TYPE STRING,
PER04 TYPE STRING,
WAERS04 TYPE STRING,
PER05 TYPE STRING,
WAERS05 TYPE STRING,
PER06 TYPE STRING,
WAERS06 TYPE STRING,
PER07 TYPE STRING,
WAERS07 TYPE STRING,
PER08 TYPE STRING,
WAERS08 TYPE STRING,
PER09 TYPE STRING,
WAERS09 TYPE STRING,
PER10 TYPE STRING,
WAERS10 TYPE STRING,
PER11 TYPE STRING,
WAERS11 TYPE STRING,
PER12 TYPE STRING,
WAERS12 TYPE STRING,
PER13 TYPE STRING,
WAERS13 TYPE STRING,
TOTAL TYPE STRING,
TOTAL_WAERS TYPE STRING,
FINAL TYPE STRING,
FINAL_WAERS TYPE STRING,
CHANGED TYPE STRING,
NLWCR TYPE STRING,
JUPER TYPE STRING,
EMPLOYER TYPE STRING,
FL_BASE TYPE STRING,
WAERSFLB TYPE STRING,
FL_CALCULATED TYPE STRING,
WAERSFLC TYPE STRING,END OF T_EKKO_STR. DATA: WA_P05T_WCR_OVERVIEW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P05T_WCR_OVERVIEW_STR-HEADER sy-vline
WA_P05T_WCR_OVERVIEW_STR-TYPE sy-vline
WA_P05T_WCR_OVERVIEW_STR-CODE sy-vline
WA_P05T_WCR_OVERVIEW_STR-CURR sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER01 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS01 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER02 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS02 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER03 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS03 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER04 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS04 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER05 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS05 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER06 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS06 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER07 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS07 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER08 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS08 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER09 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS09 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER10 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS10 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER11 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS11 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER12 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS12 sy-vline
WA_P05T_WCR_OVERVIEW_STR-PER13 sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERS13 sy-vline
WA_P05T_WCR_OVERVIEW_STR-TOTAL sy-vline
WA_P05T_WCR_OVERVIEW_STR-TOTAL_WAERS sy-vline
WA_P05T_WCR_OVERVIEW_STR-FINAL sy-vline
WA_P05T_WCR_OVERVIEW_STR-FINAL_WAERS sy-vline
WA_P05T_WCR_OVERVIEW_STR-CHANGED sy-vline
WA_P05T_WCR_OVERVIEW_STR-NLWCR sy-vline
WA_P05T_WCR_OVERVIEW_STR-JUPER sy-vline
WA_P05T_WCR_OVERVIEW_STR-EMPLOYER sy-vline
WA_P05T_WCR_OVERVIEW_STR-FL_BASE sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERSFLB sy-vline
WA_P05T_WCR_OVERVIEW_STR-FL_CALCULATED sy-vline
WA_P05T_WCR_OVERVIEW_STR-WAERSFLC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.