ABAP Select data from SAP table P05T_PR_S_EE_ADMS_VIEWER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P05T_PR_S_EE_ADMS_VIEWER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P05T_PR_S_EE_ADMS_VIEWER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P05T_PR_S_EE_ADMS_VIEWER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P05T_PR_S_EE_ADMS_VIEWER TYPE STANDARD TABLE OF P05T_PR_S_EE_ADMS_VIEWER,
      WA_P05T_PR_S_EE_ADMS_VIEWER TYPE P05T_PR_S_EE_ADMS_VIEWER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P05T_PR_S_EE_ADMS_VIEWER> TYPE P05T_PR_S_EE_ADMS_VIEWER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P05T_PR_S_EE_ADMS_VIEWER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P05T_PR_S_EE_ADMS_VIEWER
  INTO TABLE IT_P05T_PR_S_EE_ADMS_VIEWER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P05T_PR_S_EE_ADMS_VIEWER
*  INTO TABLE @DATA(IT_P05T_PR_S_EE_ADMS_VIEWER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P05T_PR_S_EE_ADMS_VIEWER INDEX 1 INTO DATA(WA_P05T_PR_S_EE_ADMS_VIEWER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P05T_PR_S_EE_ADMS_VIEWER ASSIGNING <P05T_PR_S_EE_ADMS_VIEWER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P05T_PR_S_EE_ADMS_VIEWER>-MANDT = 1.
<P05T_PR_S_EE_ADMS_VIEWER>-APPL = 1.
<P05T_PR_S_EE_ADMS_VIEWER>-JUPER = 1.
<P05T_PR_S_EE_ADMS_VIEWER>-WERKS = 1.
<P05T_PR_S_EE_ADMS_VIEWER>-REGYR = 1.
ENDLOOP.

LOOP AT IT_P05T_PR_S_EE_ADMS_VIEWER INTO WA_P05T_PR_S_EE_ADMS_VIEWER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P05T_PR_S_EE_ADMS_VIEWER-REGPE, sy-vline,
WA_P05T_PR_S_EE_ADMS_VIEWER-SEQNO, sy-vline,
WA_P05T_PR_S_EE_ADMS_VIEWER-REPTP, sy-vline,
WA_P05T_PR_S_EE_ADMS_VIEWER-PERNR, sy-vline,
WA_P05T_PR_S_EE_ADMS_VIEWER-BEGDA_IR, sy-vline,
WA_P05T_PR_S_EE_ADMS_VIEWER-SEQNOSTATUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P05T_PR_S_EE_ADMS_VIEWER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P05T_PR_S_EE_ADMS_VIEWER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P05T_PR_S_EE_ADMS_VIEWER INTO WA_P05T_PR_S_EE_ADMS_VIEWER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field REGYR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_P05T_PR_S_EE_ADMS_VIEWER-REGYR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P05T_PR_S_EE_ADMS_VIEWER-REGYR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field INPERJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_P05T_PR_S_EE_ADMS_VIEWER-INPERJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P05T_PR_S_EE_ADMS_VIEWER-INPERJ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P05T_PR_S_EE_ADMS_VIEWER_STR,
MANDT TYPE STRING,
APPL TYPE STRING,
JUPER TYPE STRING,
WERKS TYPE STRING,
REGYR TYPE STRING,
REGPE TYPE STRING,
SEQNO TYPE STRING,
REPTP TYPE STRING,
PERNR TYPE STRING,
BEGDA_IR TYPE STRING,
SEQNOSTATUS TYPE STRING,
STATUS TYPE STRING,
REPORT TYPE STRING,
UNAME TYPE STRING,
GDATE TYPE STRING,
GTIME TYPE STRING,
INPERJ TYPE STRING,
INPERP TYPE STRING,
STATUS_TXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_P05T_PR_S_EE_ADMS_VIEWER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-MANDT sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-APPL sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-JUPER sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-WERKS sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-REGYR sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-REGPE sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-SEQNO sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-REPTP sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-PERNR sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-BEGDA_IR sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-SEQNOSTATUS sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-STATUS sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-REPORT sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-UNAME sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-GDATE sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-GTIME sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-INPERJ sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-INPERP sy-vline
WA_P05T_PR_S_EE_ADMS_VIEWER_STR-STATUS_TXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.