ABAP Select data from SAP table P05_SV_PR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P05_SV_PR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P05_SV_PR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P05_SV_PR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P05_SV_PR TYPE STANDARD TABLE OF P05_SV_PR,
      WA_P05_SV_PR TYPE P05_SV_PR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P05_SV_PR> TYPE P05_SV_PR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P05_SV_PR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P05_SV_PR
  INTO TABLE IT_P05_SV_PR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P05_SV_PR
*  INTO TABLE @DATA(IT_P05_SV_PR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P05_SV_PR INDEX 1 INTO DATA(WA_P05_SV_PR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P05_SV_PR ASSIGNING <P05_SV_PR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P05_SV_PR>-SVTAK = 1.
<P05_SV_PR>-SVVNR = 1.
<P05_SV_PR>-SVSRT = 1.
<P05_SV_PR>-PRPLC = 1.
<P05_SV_PR>-SECTOR = 1.
ENDLOOP.

LOOP AT IT_P05_SV_PR INTO WA_P05_SV_PR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P05_SV_PR-RISICOGROEP, sy-vline,
WA_P05_SV_PR-SVMET, sy-vline,
WA_P05_SV_PR-A_CLN, sy-vline,
WA_P05_SV_PR-A_CLN_BB, sy-vline,
WA_P05_SV_PR-A_CLN_CUM, sy-vline,
WA_P05_SV_PR-A_MAX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P05_SV_PR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P05_SV_PR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P05_SV_PR INTO WA_P05_SV_PR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P05_SV_PR_STR,
SVTAK TYPE STRING,
SVVNR TYPE STRING,
SVSRT TYPE STRING,
PRPLC TYPE STRING,
SECTOR TYPE STRING,
RISICOGROEP TYPE STRING,
SVMET TYPE STRING,
A_CLN TYPE STRING,
A_CLN_BB TYPE STRING,
A_CLN_CUM TYPE STRING,
A_MAX TYPE STRING,
A_MAX_BB TYPE STRING,
A_MAX_CUM TYPE STRING,
A_FRC TYPE STRING,
A_FRC_BB TYPE STRING,
A_FRC_CUM TYPE STRING,
A_PLN TYPE STRING,
A_PLN_BB TYPE STRING,
A_PLN_TOT TYPE STRING,
A_PLN_CUM TYPE STRING,
A_PWG TYPE STRING,
A_PWG_BB TYPE STRING,
A_PWG_TOT TYPE STRING,
A_PWG_CUM TYPE STRING,
A_PWN TYPE STRING,
A_PWN_BB TYPE STRING,
A_PWN_TOT TYPE STRING,
A_PWN_CUM TYPE STRING,
A_SVD TYPE STRING,
A_SVD_CUM TYPE STRING,
A_SVW TYPE STRING,
A_SVW_CUM TYPE STRING,
A_SV4 TYPE STRING,
A_SV4_CUM TYPE STRING,
A_SVM TYPE STRING,
A_SVM_CUM TYPE STRING,
T_SVD TYPE STRING,
A_PTP TYPE STRING,
A_UPW TYPE STRING,END OF T_EKKO_STR. DATA: WA_P05_SV_PR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P05_SV_PR_STR-SVTAK sy-vline
WA_P05_SV_PR_STR-SVVNR sy-vline
WA_P05_SV_PR_STR-SVSRT sy-vline
WA_P05_SV_PR_STR-PRPLC sy-vline
WA_P05_SV_PR_STR-SECTOR sy-vline
WA_P05_SV_PR_STR-RISICOGROEP sy-vline
WA_P05_SV_PR_STR-SVMET sy-vline
WA_P05_SV_PR_STR-A_CLN sy-vline
WA_P05_SV_PR_STR-A_CLN_BB sy-vline
WA_P05_SV_PR_STR-A_CLN_CUM sy-vline
WA_P05_SV_PR_STR-A_MAX sy-vline
WA_P05_SV_PR_STR-A_MAX_BB sy-vline
WA_P05_SV_PR_STR-A_MAX_CUM sy-vline
WA_P05_SV_PR_STR-A_FRC sy-vline
WA_P05_SV_PR_STR-A_FRC_BB sy-vline
WA_P05_SV_PR_STR-A_FRC_CUM sy-vline
WA_P05_SV_PR_STR-A_PLN sy-vline
WA_P05_SV_PR_STR-A_PLN_BB sy-vline
WA_P05_SV_PR_STR-A_PLN_TOT sy-vline
WA_P05_SV_PR_STR-A_PLN_CUM sy-vline
WA_P05_SV_PR_STR-A_PWG sy-vline
WA_P05_SV_PR_STR-A_PWG_BB sy-vline
WA_P05_SV_PR_STR-A_PWG_TOT sy-vline
WA_P05_SV_PR_STR-A_PWG_CUM sy-vline
WA_P05_SV_PR_STR-A_PWN sy-vline
WA_P05_SV_PR_STR-A_PWN_BB sy-vline
WA_P05_SV_PR_STR-A_PWN_TOT sy-vline
WA_P05_SV_PR_STR-A_PWN_CUM sy-vline
WA_P05_SV_PR_STR-A_SVD sy-vline
WA_P05_SV_PR_STR-A_SVD_CUM sy-vline
WA_P05_SV_PR_STR-A_SVW sy-vline
WA_P05_SV_PR_STR-A_SVW_CUM sy-vline
WA_P05_SV_PR_STR-A_SV4 sy-vline
WA_P05_SV_PR_STR-A_SV4_CUM sy-vline
WA_P05_SV_PR_STR-A_SVM sy-vline
WA_P05_SV_PR_STR-A_SVM_CUM sy-vline
WA_P05_SV_PR_STR-T_SVD sy-vline
WA_P05_SV_PR_STR-A_PTP sy-vline
WA_P05_SV_PR_STR-A_UPW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.