ABAP Select data from SAP table P05_RPICSRN0_ALV_02 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P05_RPICSRN0_ALV_02 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P05_RPICSRN0_ALV_02. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P05_RPICSRN0_ALV_02 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P05_RPICSRN0_ALV_02 TYPE STANDARD TABLE OF P05_RPICSRN0_ALV_02,
      WA_P05_RPICSRN0_ALV_02 TYPE P05_RPICSRN0_ALV_02,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P05_RPICSRN0_ALV_02> TYPE P05_RPICSRN0_ALV_02.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P05_RPICSRN0_ALV_02.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P05_RPICSRN0_ALV_02
  INTO TABLE IT_P05_RPICSRN0_ALV_02.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P05_RPICSRN0_ALV_02
*  INTO TABLE @DATA(IT_P05_RPICSRN0_ALV_022).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P05_RPICSRN0_ALV_02 INDEX 1 INTO DATA(WA_P05_RPICSRN0_ALV_022).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P05_RPICSRN0_ALV_02 ASSIGNING <P05_RPICSRN0_ALV_02>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P05_RPICSRN0_ALV_02>-PERNR = 1.
<P05_RPICSRN0_ALV_02>-ENAME = 1.
<P05_RPICSRN0_ALV_02>-SUBTY = 1.
<P05_RPICSRN0_ALV_02>-BEGDA = 1.
<P05_RPICSRN0_ALV_02>-ENDDA = 1.
ENDLOOP.

LOOP AT IT_P05_RPICSRN0_ALV_02 INTO WA_P05_RPICSRN0_ALV_02.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P05_RPICSRN0_ALV_02-BETRS, sy-vline,
WA_P05_RPICSRN0_ALV_02-PCTWN, sy-vline,
WA_P05_RPICSRN0_ALV_02-ZFPER, sy-vline,
WA_P05_RPICSRN0_ALV_02-ZANZL, sy-vline,
WA_P05_RPICSRN0_ALV_02-LLUBB, sy-vline,
WA_P05_RPICSRN0_ALV_02-LLRGR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P05_RPICSRN0_ALV_02 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P05_RPICSRN0_ALV_02 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P05_RPICSRN0_ALV_02 INTO WA_P05_RPICSRN0_ALV_02. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P05_RPICSRN0_ALV_02_STR,
PERNR TYPE STRING,
ENAME TYPE STRING,
SUBTY TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
BETRS TYPE STRING,
PCTWN TYPE STRING,
ZFPER TYPE STRING,
ZANZL TYPE STRING,
LLUBB TYPE STRING,
LLRGR TYPE STRING,
BDRWG TYPE STRING,
PCTWG TYPE STRING,
UNAME TYPE STRING,
BETRB TYPE STRING,
PWNBB TYPE STRING,
ESPBB TYPE STRING,
INTBB TYPE STRING,
FWGBB TYPE STRING,
BEGDA_EIN TYPE STRING,
ENDDA_EIN TYPE STRING,
STATUS02_BIM TYPE STRING,
REC02_OK TYPE STRING,
EMFSS TYPE STRING,
EMFTS TYPE STRING,
BKPLS TYPE STRING,
BKORS TYPE STRING,
BASKS TYPE STRING,
BASKL TYPE STRING,
BASKN TYPE STRING,
ZLSCS TYPE STRING,
ZWECK TYPE STRING,
IBANS TYPE STRING,END OF T_EKKO_STR. DATA: WA_P05_RPICSRN0_ALV_02_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P05_RPICSRN0_ALV_02_STR-PERNR sy-vline
WA_P05_RPICSRN0_ALV_02_STR-ENAME sy-vline
WA_P05_RPICSRN0_ALV_02_STR-SUBTY sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BEGDA sy-vline
WA_P05_RPICSRN0_ALV_02_STR-ENDDA sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BETRS sy-vline
WA_P05_RPICSRN0_ALV_02_STR-PCTWN sy-vline
WA_P05_RPICSRN0_ALV_02_STR-ZFPER sy-vline
WA_P05_RPICSRN0_ALV_02_STR-ZANZL sy-vline
WA_P05_RPICSRN0_ALV_02_STR-LLUBB sy-vline
WA_P05_RPICSRN0_ALV_02_STR-LLRGR sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BDRWG sy-vline
WA_P05_RPICSRN0_ALV_02_STR-PCTWG sy-vline
WA_P05_RPICSRN0_ALV_02_STR-UNAME sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BETRB sy-vline
WA_P05_RPICSRN0_ALV_02_STR-PWNBB sy-vline
WA_P05_RPICSRN0_ALV_02_STR-ESPBB sy-vline
WA_P05_RPICSRN0_ALV_02_STR-INTBB sy-vline
WA_P05_RPICSRN0_ALV_02_STR-FWGBB sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BEGDA_EIN sy-vline
WA_P05_RPICSRN0_ALV_02_STR-ENDDA_EIN sy-vline
WA_P05_RPICSRN0_ALV_02_STR-STATUS02_BIM sy-vline
WA_P05_RPICSRN0_ALV_02_STR-REC02_OK sy-vline
WA_P05_RPICSRN0_ALV_02_STR-EMFSS sy-vline
WA_P05_RPICSRN0_ALV_02_STR-EMFTS sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BKPLS sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BKORS sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BASKS sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BASKL sy-vline
WA_P05_RPICSRN0_ALV_02_STR-BASKN sy-vline
WA_P05_RPICSRN0_ALV_02_STR-ZLSCS sy-vline
WA_P05_RPICSRN0_ALV_02_STR-ZWECK sy-vline
WA_P05_RPICSRN0_ALV_02_STR-IBANS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.