ABAP Select data from SAP table P02VS_PR_TAB_RECORD_DATA1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P02VS_PR_TAB_RECORD_DATA1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P02VS_PR_TAB_RECORD_DATA1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P02VS_PR_TAB_RECORD_DATA1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P02VS_PR_TAB_RECORD_DATA1 TYPE STANDARD TABLE OF P02VS_PR_TAB_RECORD_DATA1,
      WA_P02VS_PR_TAB_RECORD_DATA1 TYPE P02VS_PR_TAB_RECORD_DATA1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P02VS_PR_TAB_RECORD_DATA1> TYPE P02VS_PR_TAB_RECORD_DATA1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P02VS_PR_TAB_RECORD_DATA1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P02VS_PR_TAB_RECORD_DATA1
  INTO TABLE IT_P02VS_PR_TAB_RECORD_DATA1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P02VS_PR_TAB_RECORD_DATA1
*  INTO TABLE @DATA(IT_P02VS_PR_TAB_RECORD_DATA12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P02VS_PR_TAB_RECORD_DATA1 INDEX 1 INTO DATA(WA_P02VS_PR_TAB_RECORD_DATA12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P02VS_PR_TAB_RECORD_DATA1 ASSIGNING <P02VS_PR_TAB_RECORD_DATA1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P02VS_PR_TAB_RECORD_DATA1>-V0401 = 1.
<P02VS_PR_TAB_RECORD_DATA1>-V0402 = 1.
<P02VS_PR_TAB_RECORD_DATA1>-V0403 = 1.
<P02VS_PR_TAB_RECORD_DATA1>-V0404 = 1.
<P02VS_PR_TAB_RECORD_DATA1>-V0405 = 1.
ENDLOOP.

LOOP AT IT_P02VS_PR_TAB_RECORD_DATA1 INTO WA_P02VS_PR_TAB_RECORD_DATA1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P02VS_PR_TAB_RECORD_DATA1-V0406, sy-vline,
WA_P02VS_PR_TAB_RECORD_DATA1-V0407, sy-vline,
WA_P02VS_PR_TAB_RECORD_DATA1-V0408, sy-vline,
WA_P02VS_PR_TAB_RECORD_DATA1-V0409, sy-vline,
WA_P02VS_PR_TAB_RECORD_DATA1-V0410, sy-vline,
WA_P02VS_PR_TAB_RECORD_DATA1-V0501, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P02VS_PR_TAB_RECORD_DATA1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P02VS_PR_TAB_RECORD_DATA1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P02VS_PR_TAB_RECORD_DATA1 INTO WA_P02VS_PR_TAB_RECORD_DATA1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P02VS_PR_TAB_RECORD_DATA1_STR,
V0401 TYPE STRING,
V0402 TYPE STRING,
V0403 TYPE STRING,
V0404 TYPE STRING,
V0405 TYPE STRING,
V0406 TYPE STRING,
V0407 TYPE STRING,
V0408 TYPE STRING,
V0409 TYPE STRING,
V0410 TYPE STRING,
V0501 TYPE STRING,
V0502 TYPE STRING,
V0503 TYPE STRING,
V0504 TYPE STRING,
V0505 TYPE STRING,
V0506 TYPE STRING,
V0507 TYPE STRING,
V0508 TYPE STRING,
V0509 TYPE STRING,
V0510 TYPE STRING,
V0511 TYPE STRING,
V0512 TYPE STRING,
V0513 TYPE STRING,
V0514 TYPE STRING,
V0515 TYPE STRING,
V9901 TYPE STRING,
V9902 TYPE STRING,
V9903 TYPE STRING,
V9904 TYPE STRING,
V9905 TYPE STRING,
V9906 TYPE STRING,
V9907 TYPE STRING,
V9908 TYPE STRING,
V9909 TYPE STRING,
V9910 TYPE STRING,END OF T_EKKO_STR. DATA: WA_P02VS_PR_TAB_RECORD_DATA1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0401 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0402 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0403 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0404 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0405 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0406 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0407 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0408 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0409 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0410 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0501 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0502 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0503 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0504 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0505 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0506 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0507 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0508 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0509 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0510 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0511 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0512 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0513 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0514 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V0515 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9901 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9902 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9903 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9904 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9905 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9906 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9907 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9908 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9909 sy-vline
WA_P02VS_PR_TAB_RECORD_DATA1_STR-V9910 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.