ABAP Select data from SAP table P02RPLKUAC0_ALV2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P02RPLKUAC0_ALV2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P02RPLKUAC0_ALV2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P02RPLKUAC0_ALV2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P02RPLKUAC0_ALV2 TYPE STANDARD TABLE OF P02RPLKUAC0_ALV2,
      WA_P02RPLKUAC0_ALV2 TYPE P02RPLKUAC0_ALV2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P02RPLKUAC0_ALV2> TYPE P02RPLKUAC0_ALV2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P02RPLKUAC0_ALV2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P02RPLKUAC0_ALV2
  INTO TABLE IT_P02RPLKUAC0_ALV2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P02RPLKUAC0_ALV2
*  INTO TABLE @DATA(IT_P02RPLKUAC0_ALV22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P02RPLKUAC0_ALV2 INDEX 1 INTO DATA(WA_P02RPLKUAC0_ALV22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P02RPLKUAC0_ALV2 ASSIGNING <P02RPLKUAC0_ALV2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P02RPLKUAC0_ALV2>-BUKRS = 1.
<P02RPLKUAC0_ALV2>-BTABT = 1.
<P02RPLKUAC0_ALV2>-BATYP = 1.
<P02RPLKUAC0_ALV2>-VNOUT = 1.
<P02RPLKUAC0_ALV2>-AHVNR = 1.
ENDLOOP.

LOOP AT IT_P02RPLKUAC0_ALV2 INTO WA_P02RPLKUAC0_ALV2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P02RPLKUAC0_ALV2-PERNR, sy-vline,
WA_P02RPLKUAC0_ALV2-ENAME, sy-vline,
WA_P02RPLKUAC0_ALV2-STDSATZ, sy-vline,
WA_P02RPLKUAC0_ALV2-AZWOCHE, sy-vline,
WA_P02RPLKUAC0_ALV2-SOLLSTD, sy-vline,
WA_P02RPLKUAC0_ALV2-ISTSTD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P02RPLKUAC0_ALV2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P02RPLKUAC0_ALV2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P02RPLKUAC0_ALV2 INTO WA_P02RPLKUAC0_ALV2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P02RPLKUAC0_ALV2_STR,
BUKRS TYPE STRING,
BTABT TYPE STRING,
BATYP TYPE STRING,
VNOUT TYPE STRING,
AHVNR TYPE STRING,
PERNR TYPE STRING,
ENAME TYPE STRING,
STDSATZ TYPE STRING,
AZWOCHE TYPE STRING,
SOLLSTD TYPE STRING,
ISTSTD TYPE STRING,
ABSENZEN TYPE STRING,
GLZENDEVM TYPE STRING,
GLZENDELM TYPE STRING,
GLZDIFF TYPE STRING,
AUSFALLSTD TYPE STRING,
MEHRVORMO TYPE STRING,
SAISOAUSF TYPE STRING,
ANRECHSTD TYPE STRING,
LOHNAUS100 TYPE STRING,
LOHNAUS80 TYPE STRING,
KARENZTAG TYPE STRING,
ANSPRUCHALV TYPE STRING,
SV TYPE STRING,
CO19_AHVPFL TYPE STRING,
CO19_NUM_AFCTD TYPE STRING,
CO19_NUM_ENTLD TYPE STRING,
CO19_SW_HAS_AUSF_STD TYPE STRING,
CO19B_SW_LOW_INCOME TYPE STRING,
CO19B_EMPCT TYPE STRING,
CO19B_WEWOTIME100 TYPE STRING,
CO19B_MON_WAGE100 TYPE STRING,END OF T_EKKO_STR. DATA: WA_P02RPLKUAC0_ALV2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P02RPLKUAC0_ALV2_STR-BUKRS sy-vline
WA_P02RPLKUAC0_ALV2_STR-BTABT sy-vline
WA_P02RPLKUAC0_ALV2_STR-BATYP sy-vline
WA_P02RPLKUAC0_ALV2_STR-VNOUT sy-vline
WA_P02RPLKUAC0_ALV2_STR-AHVNR sy-vline
WA_P02RPLKUAC0_ALV2_STR-PERNR sy-vline
WA_P02RPLKUAC0_ALV2_STR-ENAME sy-vline
WA_P02RPLKUAC0_ALV2_STR-STDSATZ sy-vline
WA_P02RPLKUAC0_ALV2_STR-AZWOCHE sy-vline
WA_P02RPLKUAC0_ALV2_STR-SOLLSTD sy-vline
WA_P02RPLKUAC0_ALV2_STR-ISTSTD sy-vline
WA_P02RPLKUAC0_ALV2_STR-ABSENZEN sy-vline
WA_P02RPLKUAC0_ALV2_STR-GLZENDEVM sy-vline
WA_P02RPLKUAC0_ALV2_STR-GLZENDELM sy-vline
WA_P02RPLKUAC0_ALV2_STR-GLZDIFF sy-vline
WA_P02RPLKUAC0_ALV2_STR-AUSFALLSTD sy-vline
WA_P02RPLKUAC0_ALV2_STR-MEHRVORMO sy-vline
WA_P02RPLKUAC0_ALV2_STR-SAISOAUSF sy-vline
WA_P02RPLKUAC0_ALV2_STR-ANRECHSTD sy-vline
WA_P02RPLKUAC0_ALV2_STR-LOHNAUS100 sy-vline
WA_P02RPLKUAC0_ALV2_STR-LOHNAUS80 sy-vline
WA_P02RPLKUAC0_ALV2_STR-KARENZTAG sy-vline
WA_P02RPLKUAC0_ALV2_STR-ANSPRUCHALV sy-vline
WA_P02RPLKUAC0_ALV2_STR-SV sy-vline
WA_P02RPLKUAC0_ALV2_STR-CO19_AHVPFL sy-vline
WA_P02RPLKUAC0_ALV2_STR-CO19_NUM_AFCTD sy-vline
WA_P02RPLKUAC0_ALV2_STR-CO19_NUM_ENTLD sy-vline
WA_P02RPLKUAC0_ALV2_STR-CO19_SW_HAS_AUSF_STD sy-vline
WA_P02RPLKUAC0_ALV2_STR-CO19B_SW_LOW_INCOME sy-vline
WA_P02RPLKUAC0_ALV2_STR-CO19B_EMPCT sy-vline
WA_P02RPLKUAC0_ALV2_STR-CO19B_WEWOTIME100 sy-vline
WA_P02RPLKUAC0_ALV2_STR-CO19B_MON_WAGE100 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.