ABAP Select data from SAP table P01C_BEMPF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P01C_BEMPF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P01C_BEMPF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P01C_BEMPF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P01C_BEMPF TYPE STANDARD TABLE OF P01C_BEMPF,
      WA_P01C_BEMPF TYPE P01C_BEMPF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P01C_BEMPF> TYPE P01C_BEMPF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P01C_BEMPF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P01C_BEMPF
  INTO TABLE IT_P01C_BEMPF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P01C_BEMPF
*  INTO TABLE @DATA(IT_P01C_BEMPF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P01C_BEMPF INDEX 1 INTO DATA(WA_P01C_BEMPF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P01C_BEMPF ASSIGNING <P01C_BEMPF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P01C_BEMPF>-HBTYP = 1.
<P01C_BEMPF>-PERNR = 1.
<P01C_BEMPF>-SUBTY = 1.
<P01C_BEMPF>-FAMST = 1.
<P01C_BEMPF>-NATIO = 1.
ENDLOOP.

LOOP AT IT_P01C_BEMPF INTO WA_P01C_BEMPF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P01C_BEMPF-GBLND, sy-vline,
WA_P01C_BEMPF-KNZNM, sy-vline,
WA_P01C_BEMPF-ANRED, sy-vline,
WA_P01C_BEMPF-GESCH, sy-vline,
WA_P01C_BEMPF-BUKRS, sy-vline,
WA_P01C_BEMPF-WERKS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P01C_BEMPF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P01C_BEMPF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P01C_BEMPF INTO WA_P01C_BEMPF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PDATE, internal->external for field GBDAT CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_P01C_BEMPF-GBDAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P01C_BEMPF-GBDAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P01C_BEMPF_STR,
HBTYP TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
FAMST TYPE STRING,
NATIO TYPE STRING,
GBLND TYPE STRING,
KNZNM TYPE STRING,
ANRED TYPE STRING,
GESCH TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
VDSK1 TYPE STRING,
GSBER TYPE STRING,
BTRTL TYPE STRING,
JUPER TYPE STRING,
ABKRS TYPE STRING,
ANSVH TYPE STRING,
STAT1 TYPE STRING,
STAT2 TYPE STRING,
STAT3 TYPE STRING,
MASSN TYPE STRING,
MASSG TYPE STRING,
NACHN TYPE STRING,
VORNA TYPE STRING,
GBORT TYPE STRING,
GBDAT TYPE STRING,
BEGPP TYPE STRING,
ENDPP TYPE STRING,
KEYDT TYPE STRING,
FAMDT TYPE STRING,
TITEL TYPE STRING,
TITL2 TYPE STRING,
NAMZU TYPE STRING,
VORSW TYPE STRING,
VORS2 TYPE STRING,
EDATE TYPE STRING,
KZPRZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_P01C_BEMPF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P01C_BEMPF_STR-HBTYP sy-vline
WA_P01C_BEMPF_STR-PERNR sy-vline
WA_P01C_BEMPF_STR-SUBTY sy-vline
WA_P01C_BEMPF_STR-FAMST sy-vline
WA_P01C_BEMPF_STR-NATIO sy-vline
WA_P01C_BEMPF_STR-GBLND sy-vline
WA_P01C_BEMPF_STR-KNZNM sy-vline
WA_P01C_BEMPF_STR-ANRED sy-vline
WA_P01C_BEMPF_STR-GESCH sy-vline
WA_P01C_BEMPF_STR-BUKRS sy-vline
WA_P01C_BEMPF_STR-WERKS sy-vline
WA_P01C_BEMPF_STR-PERSG sy-vline
WA_P01C_BEMPF_STR-PERSK sy-vline
WA_P01C_BEMPF_STR-VDSK1 sy-vline
WA_P01C_BEMPF_STR-GSBER sy-vline
WA_P01C_BEMPF_STR-BTRTL sy-vline
WA_P01C_BEMPF_STR-JUPER sy-vline
WA_P01C_BEMPF_STR-ABKRS sy-vline
WA_P01C_BEMPF_STR-ANSVH sy-vline
WA_P01C_BEMPF_STR-STAT1 sy-vline
WA_P01C_BEMPF_STR-STAT2 sy-vline
WA_P01C_BEMPF_STR-STAT3 sy-vline
WA_P01C_BEMPF_STR-MASSN sy-vline
WA_P01C_BEMPF_STR-MASSG sy-vline
WA_P01C_BEMPF_STR-NACHN sy-vline
WA_P01C_BEMPF_STR-VORNA sy-vline
WA_P01C_BEMPF_STR-GBORT sy-vline
WA_P01C_BEMPF_STR-GBDAT sy-vline
WA_P01C_BEMPF_STR-BEGPP sy-vline
WA_P01C_BEMPF_STR-ENDPP sy-vline
WA_P01C_BEMPF_STR-KEYDT sy-vline
WA_P01C_BEMPF_STR-FAMDT sy-vline
WA_P01C_BEMPF_STR-TITEL sy-vline
WA_P01C_BEMPF_STR-TITL2 sy-vline
WA_P01C_BEMPF_STR-NAMZU sy-vline
WA_P01C_BEMPF_STR-VORSW sy-vline
WA_P01C_BEMPF_STR-VORS2 sy-vline
WA_P01C_BEMPF_STR-EDATE sy-vline
WA_P01C_BEMPF_STR-KZPRZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.