ABAP Select data from SAP table P01C_BDEJA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P01C_BDEJA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P01C_BDEJA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P01C_BDEJA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P01C_BDEJA TYPE STANDARD TABLE OF P01C_BDEJA,
      WA_P01C_BDEJA TYPE P01C_BDEJA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P01C_BDEJA> TYPE P01C_BDEJA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P01C_BDEJA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P01C_BDEJA
  INTO TABLE IT_P01C_BDEJA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P01C_BDEJA
*  INTO TABLE @DATA(IT_P01C_BDEJA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P01C_BDEJA INDEX 1 INTO DATA(WA_P01C_BDEJA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P01C_BDEJA ASSIGNING <P01C_BDEJA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P01C_BDEJA>-LTTYP = 1.
<P01C_BDEJA>-LTRGR = 1.
<P01C_BDEJA>-ANGRP = 1.
<P01C_BDEJA>-HANSP = 1.
<P01C_BDEJA>-AANSP = 1.
ENDLOOP.

LOOP AT IT_P01C_BDEJA INTO WA_P01C_BDEJA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P01C_BDEJA-MODBV, sy-vline,
WA_P01C_BDEJA-ANTYP, sy-vline,
WA_P01C_BDEJA-ANSPR, sy-vline,
WA_P01C_BDEJA-KZABL, sy-vline,
WA_P01C_BDEJA-LGART, sy-vline,
WA_P01C_BDEJA-RNTYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P01C_BDEJA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P01C_BDEJA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P01C_BDEJA INTO WA_P01C_BDEJA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P01C_BDEJA_STR,
LTTYP TYPE STRING,
LTRGR TYPE STRING,
ANGRP TYPE STRING,
HANSP TYPE STRING,
AANSP TYPE STRING,
MODBV TYPE STRING,
ANTYP TYPE STRING,
ANSPR TYPE STRING,
KZABL TYPE STRING,
LGART TYPE STRING,
RNTYP TYPE STRING,
LSTTR TYPE STRING,
LURSP TYPE STRING,
HBKRZ TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
DZTJJ TYPE STRING,
APDAT TYPE STRING,
KZZWM TYPE STRING,
KZZUZ TYPE STRING,
EINKO TYPE STRING,
DJJLK TYPE STRING,
DJJHK TYPE STRING,
FIXJJ TYPE STRING,
DJJMI TYPE STRING,
PRZFI TYPE STRING,
GSPRZ TYPE STRING,
BETRG TYPE STRING,
GPTYP TYPE STRING,
NOADD TYPE STRING,END OF T_EKKO_STR. DATA: WA_P01C_BDEJA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P01C_BDEJA_STR-LTTYP sy-vline
WA_P01C_BDEJA_STR-LTRGR sy-vline
WA_P01C_BDEJA_STR-ANGRP sy-vline
WA_P01C_BDEJA_STR-HANSP sy-vline
WA_P01C_BDEJA_STR-AANSP sy-vline
WA_P01C_BDEJA_STR-MODBV sy-vline
WA_P01C_BDEJA_STR-ANTYP sy-vline
WA_P01C_BDEJA_STR-ANSPR sy-vline
WA_P01C_BDEJA_STR-KZABL sy-vline
WA_P01C_BDEJA_STR-LGART sy-vline
WA_P01C_BDEJA_STR-RNTYP sy-vline
WA_P01C_BDEJA_STR-LSTTR sy-vline
WA_P01C_BDEJA_STR-LURSP sy-vline
WA_P01C_BDEJA_STR-HBKRZ sy-vline
WA_P01C_BDEJA_STR-BEGDA sy-vline
WA_P01C_BDEJA_STR-ENDDA sy-vline
WA_P01C_BDEJA_STR-DZTJJ sy-vline
WA_P01C_BDEJA_STR-APDAT sy-vline
WA_P01C_BDEJA_STR-KZZWM sy-vline
WA_P01C_BDEJA_STR-KZZUZ sy-vline
WA_P01C_BDEJA_STR-EINKO sy-vline
WA_P01C_BDEJA_STR-DJJLK sy-vline
WA_P01C_BDEJA_STR-DJJHK sy-vline
WA_P01C_BDEJA_STR-FIXJJ sy-vline
WA_P01C_BDEJA_STR-DJJMI sy-vline
WA_P01C_BDEJA_STR-PRZFI sy-vline
WA_P01C_BDEJA_STR-GSPRZ sy-vline
WA_P01C_BDEJA_STR-BETRG sy-vline
WA_P01C_BDEJA_STR-GPTYP sy-vline
WA_P01C_BDEJA_STR-NOADD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.