ABAP Select data from SAP table P0076 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P0076 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P0076. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P0076 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P0076 TYPE STANDARD TABLE OF P0076,
      WA_P0076 TYPE P0076,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P0076> TYPE P0076.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P0076.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P0076
  INTO TABLE IT_P0076.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P0076
*  INTO TABLE @DATA(IT_P00762).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P0076 INDEX 1 INTO DATA(WA_P00762).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P0076 ASSIGNING <P0076>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P0076>-PERNR = 1.
<P0076>-INFTY = 1.
<P0076>-SUBTY = 1.
<P0076>-OBJPS = 1.
<P0076>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_P0076 INTO WA_P0076.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P0076-ENDDA, sy-vline,
WA_P0076-BEGDA, sy-vline,
WA_P0076-SEQNR, sy-vline,
WA_P0076-AEDTM, sy-vline,
WA_P0076-UNAME, sy-vline,
WA_P0076-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P0076 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P0076 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P0076 INTO WA_P0076. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P0076_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
STATS TYPE STRING,
CASNO TYPE STRING,
SDATE TYPE STRING,
STIME TYPE STRING,
WHOUR TYPE STRING,
WGTYP TYPE STRING,
AMPTY TYPE STRING,
RULEP TYPE STRING,
OCD01 TYPE STRING,
ODT01 TYPE STRING,
OTM01 TYPE STRING,
VDT01 TYPE STRING,
YNF01 TYPE STRING,
OCD02 TYPE STRING,
ODT02 TYPE STRING,
OTM02 TYPE STRING,
VDT02 TYPE STRING,
YNF02 TYPE STRING,
OCD03 TYPE STRING,
ODT03 TYPE STRING,
OTM03 TYPE STRING,
VDT03 TYPE STRING,
YNF03 TYPE STRING,
OCD04 TYPE STRING,
ODT04 TYPE STRING,
OTM04 TYPE STRING,
VDT04 TYPE STRING,
YNF04 TYPE STRING,
OCD05 TYPE STRING,
ODT05 TYPE STRING,
OTM05 TYPE STRING,
VDT05 TYPE STRING,
YNF05 TYPE STRING,
OCD06 TYPE STRING,
ODT06 TYPE STRING,
OTM06 TYPE STRING,
VDT06 TYPE STRING,
YNF06 TYPE STRING,
OCD07 TYPE STRING,
ODT07 TYPE STRING,
OTM07 TYPE STRING,
VDT07 TYPE STRING,
YNF07 TYPE STRING,
OCD08 TYPE STRING,
ODT08 TYPE STRING,
OTM08 TYPE STRING,
VDT08 TYPE STRING,
YNF08 TYPE STRING,
OCD09 TYPE STRING,
ODT09 TYPE STRING,
OTM09 TYPE STRING,
VDT09 TYPE STRING,
YNF09 TYPE STRING,
OCD10 TYPE STRING,
ODT10 TYPE STRING,
OTM10 TYPE STRING,
VDT10 TYPE STRING,
YNF10 TYPE STRING,
OCD11 TYPE STRING,
ODT11 TYPE STRING,
OTM11 TYPE STRING,
VDT11 TYPE STRING,
YNF11 TYPE STRING,
OCD12 TYPE STRING,
ODT12 TYPE STRING,
OTM12 TYPE STRING,
VDT12 TYPE STRING,
YNF12 TYPE STRING,
OCD13 TYPE STRING,
ODT13 TYPE STRING,
OTM13 TYPE STRING,
VDT13 TYPE STRING,
YNF13 TYPE STRING,
OCD14 TYPE STRING,
ODT14 TYPE STRING,
OTM14 TYPE STRING,
VDT14 TYPE STRING,
YNF14 TYPE STRING,
OCD15 TYPE STRING,
ODT15 TYPE STRING,
OTM15 TYPE STRING,
VDT15 TYPE STRING,
YNF15 TYPE STRING,
RCD01 TYPE STRING,
REM01 TYPE STRING,
RCD02 TYPE STRING,
REM02 TYPE STRING,
RCD03 TYPE STRING,
REM03 TYPE STRING,
RCD04 TYPE STRING,
REM04 TYPE STRING,
RCD05 TYPE STRING,
REM05 TYPE STRING,
RCD06 TYPE STRING,
REM06 TYPE STRING,
RCD07 TYPE STRING,
REM07 TYPE STRING,
RCD08 TYPE STRING,
REM08 TYPE STRING,
RCD09 TYPE STRING,
REM09 TYPE STRING,
RCD10 TYPE STRING,
REM10 TYPE STRING,
RCD11 TYPE STRING,
REM11 TYPE STRING,
RCD12 TYPE STRING,
REM12 TYPE STRING,
RCD13 TYPE STRING,
REM13 TYPE STRING,
RCD14 TYPE STRING,
REM14 TYPE STRING,
RCD15 TYPE STRING,
REM15 TYPE STRING,END OF T_EKKO_STR. DATA: WA_P0076_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P0076_STR-PERNR sy-vline
WA_P0076_STR-INFTY sy-vline
WA_P0076_STR-SUBTY sy-vline
WA_P0076_STR-OBJPS sy-vline
WA_P0076_STR-SPRPS sy-vline
WA_P0076_STR-ENDDA sy-vline
WA_P0076_STR-BEGDA sy-vline
WA_P0076_STR-SEQNR sy-vline
WA_P0076_STR-AEDTM sy-vline
WA_P0076_STR-UNAME sy-vline
WA_P0076_STR-HISTO sy-vline
WA_P0076_STR-ITXEX sy-vline
WA_P0076_STR-REFEX sy-vline
WA_P0076_STR-ORDEX sy-vline
WA_P0076_STR-ITBLD sy-vline
WA_P0076_STR-PREAS sy-vline
WA_P0076_STR-FLAG1 sy-vline
WA_P0076_STR-FLAG2 sy-vline
WA_P0076_STR-FLAG3 sy-vline
WA_P0076_STR-FLAG4 sy-vline
WA_P0076_STR-RESE1 sy-vline
WA_P0076_STR-RESE2 sy-vline
WA_P0076_STR-GRPVL sy-vline
WA_P0076_STR-STATS sy-vline
WA_P0076_STR-CASNO sy-vline
WA_P0076_STR-SDATE sy-vline
WA_P0076_STR-STIME sy-vline
WA_P0076_STR-WHOUR sy-vline
WA_P0076_STR-WGTYP sy-vline
WA_P0076_STR-AMPTY sy-vline
WA_P0076_STR-RULEP sy-vline
WA_P0076_STR-OCD01 sy-vline
WA_P0076_STR-ODT01 sy-vline
WA_P0076_STR-OTM01 sy-vline
WA_P0076_STR-VDT01 sy-vline
WA_P0076_STR-YNF01 sy-vline
WA_P0076_STR-OCD02 sy-vline
WA_P0076_STR-ODT02 sy-vline
WA_P0076_STR-OTM02 sy-vline
WA_P0076_STR-VDT02 sy-vline
WA_P0076_STR-YNF02 sy-vline
WA_P0076_STR-OCD03 sy-vline
WA_P0076_STR-ODT03 sy-vline
WA_P0076_STR-OTM03 sy-vline
WA_P0076_STR-VDT03 sy-vline
WA_P0076_STR-YNF03 sy-vline
WA_P0076_STR-OCD04 sy-vline
WA_P0076_STR-ODT04 sy-vline
WA_P0076_STR-OTM04 sy-vline
WA_P0076_STR-VDT04 sy-vline
WA_P0076_STR-YNF04 sy-vline
WA_P0076_STR-OCD05 sy-vline
WA_P0076_STR-ODT05 sy-vline
WA_P0076_STR-OTM05 sy-vline
WA_P0076_STR-VDT05 sy-vline
WA_P0076_STR-YNF05 sy-vline
WA_P0076_STR-OCD06 sy-vline
WA_P0076_STR-ODT06 sy-vline
WA_P0076_STR-OTM06 sy-vline
WA_P0076_STR-VDT06 sy-vline
WA_P0076_STR-YNF06 sy-vline
WA_P0076_STR-OCD07 sy-vline
WA_P0076_STR-ODT07 sy-vline
WA_P0076_STR-OTM07 sy-vline
WA_P0076_STR-VDT07 sy-vline
WA_P0076_STR-YNF07 sy-vline
WA_P0076_STR-OCD08 sy-vline
WA_P0076_STR-ODT08 sy-vline
WA_P0076_STR-OTM08 sy-vline
WA_P0076_STR-VDT08 sy-vline
WA_P0076_STR-YNF08 sy-vline
WA_P0076_STR-OCD09 sy-vline
WA_P0076_STR-ODT09 sy-vline
WA_P0076_STR-OTM09 sy-vline
WA_P0076_STR-VDT09 sy-vline
WA_P0076_STR-YNF09 sy-vline
WA_P0076_STR-OCD10 sy-vline
WA_P0076_STR-ODT10 sy-vline
WA_P0076_STR-OTM10 sy-vline
WA_P0076_STR-VDT10 sy-vline
WA_P0076_STR-YNF10 sy-vline
WA_P0076_STR-OCD11 sy-vline
WA_P0076_STR-ODT11 sy-vline
WA_P0076_STR-OTM11 sy-vline
WA_P0076_STR-VDT11 sy-vline
WA_P0076_STR-YNF11 sy-vline
WA_P0076_STR-OCD12 sy-vline
WA_P0076_STR-ODT12 sy-vline
WA_P0076_STR-OTM12 sy-vline
WA_P0076_STR-VDT12 sy-vline
WA_P0076_STR-YNF12 sy-vline
WA_P0076_STR-OCD13 sy-vline
WA_P0076_STR-ODT13 sy-vline
WA_P0076_STR-OTM13 sy-vline
WA_P0076_STR-VDT13 sy-vline
WA_P0076_STR-YNF13 sy-vline
WA_P0076_STR-OCD14 sy-vline
WA_P0076_STR-ODT14 sy-vline
WA_P0076_STR-OTM14 sy-vline
WA_P0076_STR-VDT14 sy-vline
WA_P0076_STR-YNF14 sy-vline
WA_P0076_STR-OCD15 sy-vline
WA_P0076_STR-ODT15 sy-vline
WA_P0076_STR-OTM15 sy-vline
WA_P0076_STR-VDT15 sy-vline
WA_P0076_STR-YNF15 sy-vline
WA_P0076_STR-RCD01 sy-vline
WA_P0076_STR-REM01 sy-vline
WA_P0076_STR-RCD02 sy-vline
WA_P0076_STR-REM02 sy-vline
WA_P0076_STR-RCD03 sy-vline
WA_P0076_STR-REM03 sy-vline
WA_P0076_STR-RCD04 sy-vline
WA_P0076_STR-REM04 sy-vline
WA_P0076_STR-RCD05 sy-vline
WA_P0076_STR-REM05 sy-vline
WA_P0076_STR-RCD06 sy-vline
WA_P0076_STR-REM06 sy-vline
WA_P0076_STR-RCD07 sy-vline
WA_P0076_STR-REM07 sy-vline
WA_P0076_STR-RCD08 sy-vline
WA_P0076_STR-REM08 sy-vline
WA_P0076_STR-RCD09 sy-vline
WA_P0076_STR-REM09 sy-vline
WA_P0076_STR-RCD10 sy-vline
WA_P0076_STR-REM10 sy-vline
WA_P0076_STR-RCD11 sy-vline
WA_P0076_STR-REM11 sy-vline
WA_P0076_STR-RCD12 sy-vline
WA_P0076_STR-REM12 sy-vline
WA_P0076_STR-RCD13 sy-vline
WA_P0076_STR-REM13 sy-vline
WA_P0076_STR-RCD14 sy-vline
WA_P0076_STR-REM14 sy-vline
WA_P0076_STR-RCD15 sy-vline
WA_P0076_STR-REM15 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.