ABAP Select data from SAP table OPS_SE_SOLOGSPLNGVWCRT_INT_STY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OPS_SE_SOLOGSPLNGVWCRT_INT_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OPS_SE_SOLOGSPLNGVWCRT_INT_STY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OPS_SE_SOLOGSPLNGVWCRT_INT_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OPS_SE_SOLOGSPLNGVWCRT_INT_STY TYPE STANDARD TABLE OF OPS_SE_SOLOGSPLNGVWCRT_INT_STY,
      WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY TYPE OPS_SE_SOLOGSPLNGVWCRT_INT_STY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OPS_SE_SOLOGSPLNGVWCRT_INT_STY> TYPE OPS_SE_SOLOGSPLNGVWCRT_INT_STY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OPS_SE_SOLOGSPLNGVWCRT_INT_STY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OPS_SE_SOLOGSPLNGVWCRT_INT_STY
  INTO TABLE IT_OPS_SE_SOLOGSPLNGVWCRT_INT_STY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OPS_SE_SOLOGSPLNGVWCRT_INT_STY
*  INTO TABLE @DATA(IT_OPS_SE_SOLOGSPLNGVWCRT_INT_STY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OPS_SE_SOLOGSPLNGVWCRT_INT_STY INDEX 1 INTO DATA(WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OPS_SE_SOLOGSPLNGVWCRT_INT_STY ASSIGNING <OPS_SE_SOLOGSPLNGVWCRT_INT_STY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OPS_SE_SOLOGSPLNGVWCRT_INT_STY>-HEADER_DATA = 1.
<OPS_SE_SOLOGSPLNGVWCRT_INT_STY>-DELIV_NUMB = 1.
<OPS_SE_SOLOGSPLNGVWCRT_INT_STY>-INCOTERMS1 = 1.
<OPS_SE_SOLOGSPLNGVWCRT_INT_STY>-INCOTERMS2 = 1.
<OPS_SE_SOLOGSPLNGVWCRT_INT_STY>-ROUTE = 1.
ENDLOOP.

LOOP AT IT_OPS_SE_SOLOGSPLNGVWCRT_INT_STY INTO WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-SHIP_COND, sy-vline,
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-TOTAL_WGHT, sy-vline,
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-NET_WEIGHT, sy-vline,
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-UNIT_OF_WT, sy-vline,
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-UNIT_OF_WT_ISO, sy-vline,
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-VOLUME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OPS_SE_SOLOGSPLNGVWCRT_INT_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OPS_SE_SOLOGSPLNGVWCRT_INT_STY INTO WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_WT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-UNIT_OF_WT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-UNIT_OF_WT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUMEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-VOLUMEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-VOLUMEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRGISLIP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-GRGISLIP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-GRGISLIP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RFM_PSST_GROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-RFM_PSST_GROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-RFM_PSST_GROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SENDER_SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-SENDER_SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-SENDER_SYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECV_SYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-RECV_SYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-RECV_SYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CROSS_DOCK_PROCESS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-CROSS_DOCK_PROCESS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-CROSS_DOCK_PROCESS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CROSS_DOCK_INB_DLVRY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-CROSS_DOCK_INB_DLVRY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY-CROSS_DOCK_INB_DLVRY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR,
HEADER_DATA TYPE STRING,
DELIV_NUMB TYPE STRING,
INCOTERMS1 TYPE STRING,
INCOTERMS2 TYPE STRING,
ROUTE TYPE STRING,
SHIP_COND TYPE STRING,
TOTAL_WGHT TYPE STRING,
NET_WEIGHT TYPE STRING,
UNIT_OF_WT TYPE STRING,
UNIT_OF_WT_ISO TYPE STRING,
VOLUME TYPE STRING,
VOLUMEUNIT TYPE STRING,
VOLUMEUNIT_ISO TYPE STRING,
NOSHPUNITS TYPE STRING,
BILLOFLADING TYPE STRING,
TRANS_CAT TYPE STRING,
TRANSP_ID TYPE STRING,
GRGISLIP_NO TYPE STRING,
EXTDELV_NO TYPE STRING,
DLV_TYPE TYPE STRING,
COMPL_DLV TYPE STRING,
DLV_BLOCK TYPE STRING,
DLV_PRIO TYPE STRING,
CUST_GROUP TYPE STRING,
PICK_LOC TYPE STRING,
TRANS_GRP TYPE STRING,
SHIP_BLOCK TYPE STRING,
ROUTESCHED TYPE STRING,
SD_DOC_CAT TYPE STRING,
PREV_DOC_NO TYPE STRING,
PREV_DOC_TYPE TYPE STRING,
SD_DOC_CAT_LONG TYPE STRING,
INCOTERMSV TYPE STRING,
INCOTERMS2L TYPE STRING,
INCOTERMS3L TYPE STRING,
RFM_PSST_GROUP TYPE STRING,
HEADER_ORG TYPE STRING,
DELIV_NUMB TYPE STRING,
SHIP_POINT TYPE STRING,
SALESORG TYPE STRING,
LOADING_PT TYPE STRING,
SALES_OFF TYPE STRING,
WHSE_NO TYPE STRING,
SALES_DIST TYPE STRING,
DOOR TYPE STRING,
UNLOAD_PT TYPE STRING,
SENDER_SYSTEM TYPE STRING,
TECHN_CONTROL TYPE STRING,
DEBUG_FLG TYPE STRING,
UPD_IND TYPE STRING,
RECV_WHS_NO TYPE STRING,
RECV_SYS TYPE STRING,
DLV_TYPE TYPE STRING,
INTERNAL_QUEUE TYPE STRING,
SERVICE_CALL TYPE STRING,
HEADER_DATA_SPL TYPE STRING,
DELIV_NUMB TYPE STRING,
UNCHECKED TYPE STRING,
GEOROUTE TYPE STRING,
GEOROUTE_CHANGE_INDICATOR TYPE STRING,
CARRIER_CHANGE_INDICATOR TYPE STRING,
ORDCOMBIND TYPE STRING,
UNIT_SYSTEM TYPE STRING,
INITIATOR_PROCESS TYPE STRING,
INV_BEFORE_GI TYPE STRING,
CROSS_DOCK_PROCESS TYPE STRING,
CROSS_DOCK_INB_DLVRY TYPE STRING,
SPE_TTYPE TYPE STRING,
UNLOAD_PT TYPE STRING,
LOC_GUID TYPE STRING,
EWM_DLV_TYPE TYPE STRING,
MAX_ITEM_NUMB TYPE STRING,
TMS_PLAN_IND TYPE STRING,
LGLC_LIC_IND TYPE STRING,
HEADER_PARTNER TYPE STRING,
HEADER_PARTNER_ADDR TYPE STRING,
HEADER_DEADLINES TYPE STRING,
ITEM_DATA TYPE STRING,
ITEM_ORG TYPE STRING,
TEXT_HEADER TYPE STRING,
TEXT_LINES TYPE STRING,
RETURN_MSG TYPE STRING,
ITEM_DATA_SPL TYPE STRING,
ITEM_REFERENCE_ORDER TYPE STRING,END OF T_EKKO_STR. DATA: WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-HEADER_DATA sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-DELIV_NUMB sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-INCOTERMS1 sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-INCOTERMS2 sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-ROUTE sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SHIP_COND sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-TOTAL_WGHT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-NET_WEIGHT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-UNIT_OF_WT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-UNIT_OF_WT_ISO sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-VOLUME sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-VOLUMEUNIT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-VOLUMEUNIT_ISO sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-NOSHPUNITS sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-BILLOFLADING sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-TRANS_CAT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-TRANSP_ID sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-GRGISLIP_NO sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-EXTDELV_NO sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-DLV_TYPE sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-COMPL_DLV sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-DLV_BLOCK sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-DLV_PRIO sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-CUST_GROUP sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-PICK_LOC sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-TRANS_GRP sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SHIP_BLOCK sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-ROUTESCHED sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SD_DOC_CAT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-PREV_DOC_NO sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-PREV_DOC_TYPE sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SD_DOC_CAT_LONG sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-INCOTERMSV sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-INCOTERMS2L sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-INCOTERMS3L sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-RFM_PSST_GROUP sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-HEADER_ORG sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-DELIV_NUMB sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SHIP_POINT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SALESORG sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-LOADING_PT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SALES_OFF sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-WHSE_NO sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SALES_DIST sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-DOOR sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-UNLOAD_PT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SENDER_SYSTEM sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-TECHN_CONTROL sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-DEBUG_FLG sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-UPD_IND sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-RECV_WHS_NO sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-RECV_SYS sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-DLV_TYPE sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-INTERNAL_QUEUE sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SERVICE_CALL sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-HEADER_DATA_SPL sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-DELIV_NUMB sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-UNCHECKED sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-GEOROUTE sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-GEOROUTE_CHANGE_INDICATOR sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-CARRIER_CHANGE_INDICATOR sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-ORDCOMBIND sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-UNIT_SYSTEM sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-INITIATOR_PROCESS sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-INV_BEFORE_GI sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-CROSS_DOCK_PROCESS sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-CROSS_DOCK_INB_DLVRY sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-SPE_TTYPE sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-UNLOAD_PT sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-LOC_GUID sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-EWM_DLV_TYPE sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-MAX_ITEM_NUMB sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-TMS_PLAN_IND sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-LGLC_LIC_IND sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-HEADER_PARTNER sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-HEADER_PARTNER_ADDR sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-HEADER_DEADLINES sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-ITEM_DATA sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-ITEM_ORG sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-TEXT_HEADER sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-TEXT_LINES sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-RETURN_MSG sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-ITEM_DATA_SPL sy-vline
WA_OPS_SE_SOLOGSPLNGVWCRT_INT_STY_STR-ITEM_REFERENCE_ORDER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.