ABAP Select data from SAP table OPS_PSFCJOBT_OPR_ACT_PDF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OPS_PSFCJOBT_OPR_ACT_PDF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OPS_PSFCJOBT_OPR_ACT_PDF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OPS_PSFCJOBT_OPR_ACT_PDF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OPS_PSFCJOBT_OPR_ACT_PDF TYPE STANDARD TABLE OF OPS_PSFCJOBT_OPR_ACT_PDF,
      WA_OPS_PSFCJOBT_OPR_ACT_PDF TYPE OPS_PSFCJOBT_OPR_ACT_PDF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OPS_PSFCJOBT_OPR_ACT_PDF> TYPE OPS_PSFCJOBT_OPR_ACT_PDF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OPS_PSFCJOBT_OPR_ACT_PDF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OPS_PSFCJOBT_OPR_ACT_PDF
  INTO TABLE IT_OPS_PSFCJOBT_OPR_ACT_PDF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OPS_PSFCJOBT_OPR_ACT_PDF
*  INTO TABLE @DATA(IT_OPS_PSFCJOBT_OPR_ACT_PDF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OPS_PSFCJOBT_OPR_ACT_PDF INDEX 1 INTO DATA(WA_OPS_PSFCJOBT_OPR_ACT_PDF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OPS_PSFCJOBT_OPR_ACT_PDF ASSIGNING <OPS_PSFCJOBT_OPR_ACT_PDF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OPS_PSFCJOBT_OPR_ACT_PDF>-VORNR = 1.
<OPS_PSFCJOBT_OPR_ACT_PDF>-UVORN = 1.
<OPS_PSFCJOBT_OPR_ACT_PDF>-APLFL = 1.
<OPS_PSFCJOBT_OPR_ACT_PDF>-FLG_STXT = 1.
<OPS_PSFCJOBT_OPR_ACT_PDF>-ARBPL = 1.
ENDLOOP.

LOOP AT IT_OPS_PSFCJOBT_OPR_ACT_PDF INTO WA_OPS_PSFCJOBT_OPR_ACT_PDF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OPS_PSFCJOBT_OPR_ACT_PDF-WERKS, sy-vline,
WA_OPS_PSFCJOBT_OPR_ACT_PDF-RUECK, sy-vline,
WA_OPS_PSFCJOBT_OPR_ACT_PDF-MGVRG, sy-vline,
WA_OPS_PSFCJOBT_OPR_ACT_PDF-MEINH, sy-vline,
WA_OPS_PSFCJOBT_OPR_ACT_PDF-KOSTL, sy-vline,
WA_OPS_PSFCJOBT_OPR_ACT_PDF-STEUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OPS_PSFCJOBT_OPR_ACT_PDF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OPS_PSFCJOBT_OPR_ACT_PDF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OPS_PSFCJOBT_OPR_ACT_PDF INTO WA_OPS_PSFCJOBT_OPR_ACT_PDF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-UVORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field APLFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-APLFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-APLFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TDSPRAS1 CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-TDSPRAS1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-TDSPRAS1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TDSPRAS2 CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-TDSPRAS2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-TDSPRAS2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-PLNFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-PLNFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BEZFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-BEZFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-BEZFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR1 CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-VORNR1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-VORNR1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR2 CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-VORNR2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-VORNR2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT3 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT4 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT4 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT4.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT5 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT5 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT5.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT6 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT6 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OPS_PSFCJOBT_OPR_ACT_PDF-UNIT6.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OPS_PSFCJOBT_OPR_ACT_PDF_STR,
VORNR TYPE STRING,
UVORN TYPE STRING,
APLFL TYPE STRING,
FLG_STXT TYPE STRING,
ARBPL TYPE STRING,
WERKS TYPE STRING,
RUECK TYPE STRING,
MGVRG TYPE STRING,
MEINH TYPE STRING,
KOSTL TYPE STRING,
STEUS TYPE STRING,
SSAVD TYPE STRING,
SSAVZ TYPE STRING,
SSEDD TYPE STRING,
SSEDZ TYPE STRING,
LTXA1 TYPE STRING,
TDNAME1 TYPE STRING,
TDOBJECT1 TYPE STRING,
TDID1 TYPE STRING,
TDSPRAS1 TYPE STRING,
TDNAME2 TYPE STRING,
TDOBJECT2 TYPE STRING,
TDID2 TYPE STRING,
TDSPRAS2 TYPE STRING,
PLNFL TYPE STRING,
FLG_LOE TYPE STRING,
BEZFL TYPE STRING,
VORNR1 TYPE STRING,
VORNR2 TYPE STRING,
FLGAT TYPE STRING,
ACTXKT1 TYPE STRING,
ACTXKT2 TYPE STRING,
ACTXKT3 TYPE STRING,
ACTXKT4 TYPE STRING,
ACTXKT5 TYPE STRING,
ACTXKT6 TYPE STRING,
ACTI1 TYPE STRING,
ACTI2 TYPE STRING,
ACTI3 TYPE STRING,
ACTI4 TYPE STRING,
ACTI5 TYPE STRING,
ACTI6 TYPE STRING,
UNIT1 TYPE STRING,
UNIT2 TYPE STRING,
UNIT3 TYPE STRING,
UNIT4 TYPE STRING,
UNIT5 TYPE STRING,
UNIT6 TYPE STRING,
LAR01 TYPE STRING,
LAR02 TYPE STRING,
LAR03 TYPE STRING,
LAR04 TYPE STRING,
LAR05 TYPE STRING,
LAR06 TYPE STRING,
LTXA1_Q TYPE STRING,
FLG_NEW_PAGE TYPE STRING,
FLG_ACT_NEW TYPE STRING,END OF T_EKKO_STR. DATA: WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-VORNR sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-UVORN sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-APLFL sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-FLG_STXT sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ARBPL sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-WERKS sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-RUECK sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-MGVRG sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-MEINH sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-KOSTL sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-STEUS sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-SSAVD sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-SSAVZ sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-SSEDD sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-SSEDZ sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-LTXA1 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-TDNAME1 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-TDOBJECT1 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-TDID1 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-TDSPRAS1 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-TDNAME2 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-TDOBJECT2 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-TDID2 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-TDSPRAS2 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-PLNFL sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-FLG_LOE sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-BEZFL sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-VORNR1 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-VORNR2 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-FLGAT sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTXKT1 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTXKT2 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTXKT3 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTXKT4 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTXKT5 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTXKT6 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTI1 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTI2 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTI3 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTI4 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTI5 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-ACTI6 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-UNIT1 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-UNIT2 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-UNIT3 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-UNIT4 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-UNIT5 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-UNIT6 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-LAR01 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-LAR02 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-LAR03 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-LAR04 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-LAR05 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-LAR06 sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-LTXA1_Q sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-FLG_NEW_PAGE sy-vline
WA_OPS_PSFCJOBT_OPR_ACT_PDF_STR-FLG_ACT_NEW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.