ABAP Select data from SAP table OIUY8_NM_RPDT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUY8_NM_RPDT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUY8_NM_RPDT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIUY8_NM_RPDT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIUY8_NM_RPDT TYPE STANDARD TABLE OF OIUY8_NM_RPDT,
      WA_OIUY8_NM_RPDT TYPE OIUY8_NM_RPDT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIUY8_NM_RPDT> TYPE OIUY8_NM_RPDT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIUY8_NM_RPDT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIUY8_NM_RPDT
  INTO TABLE IT_OIUY8_NM_RPDT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIUY8_NM_RPDT
*  INTO TABLE @DATA(IT_OIUY8_NM_RPDT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIUY8_NM_RPDT INDEX 1 INTO DATA(WA_OIUY8_NM_RPDT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIUY8_NM_RPDT ASSIGNING <OIUY8_NM_RPDT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUY8_NM_RPDT>-MANDT = 1.
<OIUY8_NM_RPDT>-RUN_ID = 1.
<OIUY8_NM_RPDT>-OGRID = 1.
<OIUY8_NM_RPDT>-SALES_MMYY = 1.
<OIUY8_NM_RPDT>-ENTITY_ID = 1.
ENDLOOP.

LOOP AT IT_OIUY8_NM_RPDT INTO WA_OIUY8_NM_RPDT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIUY8_NM_RPDT-PRODUCT_CODE, sy-vline,
WA_OIUY8_NM_RPDT-TRANSACTION_CODE, sy-vline,
WA_OIUY8_NM_RPDT-REV_BOOK_ADJ_IND, sy-vline,
WA_OIUY8_NM_RPDT-ARMS_LEN_IND, sy-vline,
WA_OIUY8_NM_RPDT-ROYALTY_INT, sy-vline,
WA_OIUY8_NM_RPDT-PUN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUY8_NM_RPDT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUY8_NM_RPDT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUY8_NM_RPDT INTO WA_OIUY8_NM_RPDT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTPS, internal->external for field CHANGE_TIMESTAMP CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_OIUY8_NM_RPDT-CHANGE_TIMESTAMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUY8_NM_RPDT-CHANGE_TIMESTAMP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUY8_NM_RPDT_STR,
MANDT TYPE STRING,
RUN_ID TYPE STRING,
OGRID TYPE STRING,
SALES_MMYY TYPE STRING,
ENTITY_ID TYPE STRING,
PRODUCT_CODE TYPE STRING,
TRANSACTION_CODE TYPE STRING,
REV_BOOK_ADJ_IND TYPE STRING,
ARMS_LEN_IND TYPE STRING,
ROYALTY_INT TYPE STRING,
PUN TYPE STRING,
LEASE TYPE STRING,
GROSS_VOLUME TYPE STRING,
NGL_VOLUME TYPE STRING,
BTU TYPE STRING,
GROSS_VALUE TYPE STRING,
TRANSP_DED TYPE STRING,
MKT_DED TYPE STRING,
GAS_PROC_DED TYPE STRING,
ROYALTY_PAID TYPE STRING,
CHANGE_USER TYPE STRING,
CHANGE_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUY8_NM_RPDT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUY8_NM_RPDT_STR-MANDT sy-vline
WA_OIUY8_NM_RPDT_STR-RUN_ID sy-vline
WA_OIUY8_NM_RPDT_STR-OGRID sy-vline
WA_OIUY8_NM_RPDT_STR-SALES_MMYY sy-vline
WA_OIUY8_NM_RPDT_STR-ENTITY_ID sy-vline
WA_OIUY8_NM_RPDT_STR-PRODUCT_CODE sy-vline
WA_OIUY8_NM_RPDT_STR-TRANSACTION_CODE sy-vline
WA_OIUY8_NM_RPDT_STR-REV_BOOK_ADJ_IND sy-vline
WA_OIUY8_NM_RPDT_STR-ARMS_LEN_IND sy-vline
WA_OIUY8_NM_RPDT_STR-ROYALTY_INT sy-vline
WA_OIUY8_NM_RPDT_STR-PUN sy-vline
WA_OIUY8_NM_RPDT_STR-LEASE sy-vline
WA_OIUY8_NM_RPDT_STR-GROSS_VOLUME sy-vline
WA_OIUY8_NM_RPDT_STR-NGL_VOLUME sy-vline
WA_OIUY8_NM_RPDT_STR-BTU sy-vline
WA_OIUY8_NM_RPDT_STR-GROSS_VALUE sy-vline
WA_OIUY8_NM_RPDT_STR-TRANSP_DED sy-vline
WA_OIUY8_NM_RPDT_STR-MKT_DED sy-vline
WA_OIUY8_NM_RPDT_STR-GAS_PROC_DED sy-vline
WA_OIUY8_NM_RPDT_STR-ROYALTY_PAID sy-vline
WA_OIUY8_NM_RPDT_STR-CHANGE_USER sy-vline
WA_OIUY8_NM_RPDT_STR-CHANGE_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.