ABAP Select data from SAP table OIUX8_NM_RPSM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUX8_NM_RPSM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUX8_NM_RPSM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIUX8_NM_RPSM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIUX8_NM_RPSM TYPE STANDARD TABLE OF OIUX8_NM_RPSM,
      WA_OIUX8_NM_RPSM TYPE OIUX8_NM_RPSM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIUX8_NM_RPSM> TYPE OIUX8_NM_RPSM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIUX8_NM_RPSM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIUX8_NM_RPSM
  INTO TABLE IT_OIUX8_NM_RPSM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIUX8_NM_RPSM
*  INTO TABLE @DATA(IT_OIUX8_NM_RPSM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIUX8_NM_RPSM INDEX 1 INTO DATA(WA_OIUX8_NM_RPSM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIUX8_NM_RPSM ASSIGNING <OIUX8_NM_RPSM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUX8_NM_RPSM>-MANDT = 1.
<OIUX8_NM_RPSM>-RUN_ID = 1.
<OIUX8_NM_RPSM>-OGRID = 1.
<OIUX8_NM_RPSM>-OPER_PURCH_IND = 1.
<OIUX8_NM_RPSM>-TRANS_CODE_55 = 1.
ENDLOOP.

LOOP AT IT_OIUX8_NM_RPSM INTO WA_OIUX8_NM_RPSM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIUX8_NM_RPSM-EST_PAYMENT, sy-vline,
WA_OIUX8_NM_RPSM-PREV_APPLIED_EST, sy-vline,
WA_OIUX8_NM_RPSM-TOTAL_TAX_AMT, sy-vline,
WA_OIUX8_NM_RPSM-TOTAL_ASSESS_PD, sy-vline,
WA_OIUX8_NM_RPSM-TOTAL_TAX_DUE, sy-vline,
WA_OIUX8_NM_RPSM-TOTAL_CREDITS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUX8_NM_RPSM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUX8_NM_RPSM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUX8_NM_RPSM INTO WA_OIUX8_NM_RPSM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUX8_NM_RPSM_STR,
MANDT TYPE STRING,
RUN_ID TYPE STRING,
OGRID TYPE STRING,
OPER_PURCH_IND TYPE STRING,
TRANS_CODE_55 TYPE STRING,
EST_PAYMENT TYPE STRING,
PREV_APPLIED_EST TYPE STRING,
TOTAL_TAX_AMT TYPE STRING,
TOTAL_ASSESS_PD TYPE STRING,
TOTAL_TAX_DUE TYPE STRING,
TOTAL_CREDITS TYPE STRING,
TOTAL_OVERPAYS TYPE STRING,
CR_OVERPAYS_TKN TYPE STRING,
NET_ADV_PAYMENT TYPE STRING,
TOTAL_REMITTANCE TYPE STRING,
DEBIT_CREDIT TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUX8_NM_RPSM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUX8_NM_RPSM_STR-MANDT sy-vline
WA_OIUX8_NM_RPSM_STR-RUN_ID sy-vline
WA_OIUX8_NM_RPSM_STR-OGRID sy-vline
WA_OIUX8_NM_RPSM_STR-OPER_PURCH_IND sy-vline
WA_OIUX8_NM_RPSM_STR-TRANS_CODE_55 sy-vline
WA_OIUX8_NM_RPSM_STR-EST_PAYMENT sy-vline
WA_OIUX8_NM_RPSM_STR-PREV_APPLIED_EST sy-vline
WA_OIUX8_NM_RPSM_STR-TOTAL_TAX_AMT sy-vline
WA_OIUX8_NM_RPSM_STR-TOTAL_ASSESS_PD sy-vline
WA_OIUX8_NM_RPSM_STR-TOTAL_TAX_DUE sy-vline
WA_OIUX8_NM_RPSM_STR-TOTAL_CREDITS sy-vline
WA_OIUX8_NM_RPSM_STR-TOTAL_OVERPAYS sy-vline
WA_OIUX8_NM_RPSM_STR-CR_OVERPAYS_TKN sy-vline
WA_OIUX8_NM_RPSM_STR-NET_ADV_PAYMENT sy-vline
WA_OIUX8_NM_RPSM_STR-TOTAL_REMITTANCE sy-vline
WA_OIUX8_NM_RPSM_STR-DEBIT_CREDIT sy-vline
WA_OIUX8_NM_RPSM_STR-OIU_CRUSER sy-vline
WA_OIUX8_NM_RPSM_STR-OIU_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.