ABAP Select data from SAP table OIUX1_ARCH_VOLH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUX1_ARCH_VOLH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUX1_ARCH_VOLH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIUX1_ARCH_VOLH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIUX1_ARCH_VOLH TYPE STANDARD TABLE OF OIUX1_ARCH_VOLH,
      WA_OIUX1_ARCH_VOLH TYPE OIUX1_ARCH_VOLH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIUX1_ARCH_VOLH> TYPE OIUX1_ARCH_VOLH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIUX1_ARCH_VOLH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIUX1_ARCH_VOLH
  INTO TABLE IT_OIUX1_ARCH_VOLH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIUX1_ARCH_VOLH
*  INTO TABLE @DATA(IT_OIUX1_ARCH_VOLH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIUX1_ARCH_VOLH INDEX 1 INTO DATA(WA_OIUX1_ARCH_VOLH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIUX1_ARCH_VOLH ASSIGNING <OIUX1_ARCH_VOLH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUX1_ARCH_VOLH>-MANDT = 1.
<OIUX1_ARCH_VOLH>-RPT_YYYYMM = 1.
<OIUX1_ARCH_VOLH>-RSG = 1.
<OIUX1_ARCH_VOLH>-AGENCY = 1.
<OIUX1_ARCH_VOLH>-OGIND = 1.
ENDLOOP.

LOOP AT IT_OIUX1_ARCH_VOLH INTO WA_OIUX1_ARCH_VOLH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIUX1_ARCH_VOLH-SALES_YYYYMM, sy-vline,
WA_OIUX1_ARCH_VOLH-PUID, sy-vline,
WA_OIUX1_ARCH_VOLH-AGENCY_PROD_CODE, sy-vline,
WA_OIUX1_ARCH_VOLH-AGENCY_VOL_TYPE, sy-vline,
WA_OIUX1_ARCH_VOLH-UNIT_VNAME, sy-vline,
WA_OIUX1_ARCH_VOLH-VOL_SOURCE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUX1_ARCH_VOLH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUX1_ARCH_VOLH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUX1_ARCH_VOLH INTO WA_OIUX1_ARCH_VOLH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field UNIT_VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUX1_ARCH_VOLH-UNIT_VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUX1_ARCH_VOLH-UNIT_VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STD_VOL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUX1_ARCH_VOLH-STD_VOL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUX1_ARCH_VOLH-STD_VOL_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUX1_ARCH_VOLH-ENERGY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUX1_ARCH_VOLH-ENERGY_U.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUX1_ARCH_VOLH_STR,
MANDT TYPE STRING,
RPT_YYYYMM TYPE STRING,
RSG TYPE STRING,
AGENCY TYPE STRING,
OGIND TYPE STRING,
SALES_YYYYMM TYPE STRING,
PUID TYPE STRING,
AGENCY_PROD_CODE TYPE STRING,
AGENCY_VOL_TYPE TYPE STRING,
UNIT_VNAME TYPE STRING,
VOL_SOURCE TYPE STRING,
STD_VOL TYPE STRING,
STD_VOL_U TYPE STRING,
ENERGY TYPE STRING,
ENERGY_U TYPE STRING,
VALUE TYPE STRING,
CURRENCY TYPE STRING,
USERNAME TYPE STRING,
TIMESTAMP TYPE STRING,
UPLOAD TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUX1_ARCH_VOLH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUX1_ARCH_VOLH_STR-MANDT sy-vline
WA_OIUX1_ARCH_VOLH_STR-RPT_YYYYMM sy-vline
WA_OIUX1_ARCH_VOLH_STR-RSG sy-vline
WA_OIUX1_ARCH_VOLH_STR-AGENCY sy-vline
WA_OIUX1_ARCH_VOLH_STR-OGIND sy-vline
WA_OIUX1_ARCH_VOLH_STR-SALES_YYYYMM sy-vline
WA_OIUX1_ARCH_VOLH_STR-PUID sy-vline
WA_OIUX1_ARCH_VOLH_STR-AGENCY_PROD_CODE sy-vline
WA_OIUX1_ARCH_VOLH_STR-AGENCY_VOL_TYPE sy-vline
WA_OIUX1_ARCH_VOLH_STR-UNIT_VNAME sy-vline
WA_OIUX1_ARCH_VOLH_STR-VOL_SOURCE sy-vline
WA_OIUX1_ARCH_VOLH_STR-STD_VOL sy-vline
WA_OIUX1_ARCH_VOLH_STR-STD_VOL_U sy-vline
WA_OIUX1_ARCH_VOLH_STR-ENERGY sy-vline
WA_OIUX1_ARCH_VOLH_STR-ENERGY_U sy-vline
WA_OIUX1_ARCH_VOLH_STR-VALUE sy-vline
WA_OIUX1_ARCH_VOLH_STR-CURRENCY sy-vline
WA_OIUX1_ARCH_VOLH_STR-USERNAME sy-vline
WA_OIUX1_ARCH_VOLH_STR-TIMESTAMP sy-vline
WA_OIUX1_ARCH_VOLH_STR-UPLOAD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.