ABAP Select data from SAP table OIUVL_GASDTL_CUR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUVL_GASDTL_CUR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUVL_GASDTL_CUR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIUVL_GASDTL_CUR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIUVL_GASDTL_CUR TYPE STANDARD TABLE OF OIUVL_GASDTL_CUR,
      WA_OIUVL_GASDTL_CUR TYPE OIUVL_GASDTL_CUR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIUVL_GASDTL_CUR> TYPE OIUVL_GASDTL_CUR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIUVL_GASDTL_CUR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIUVL_GASDTL_CUR
  INTO TABLE IT_OIUVL_GASDTL_CUR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIUVL_GASDTL_CUR
*  INTO TABLE @DATA(IT_OIUVL_GASDTL_CUR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIUVL_GASDTL_CUR INDEX 1 INTO DATA(WA_OIUVL_GASDTL_CUR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIUVL_GASDTL_CUR ASSIGNING <OIUVL_GASDTL_CUR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUVL_GASDTL_CUR>-MANDT = 1.
<OIUVL_GASDTL_CUR>-GASSTMTH_NO = 1.
<OIUVL_GASDTL_CUR>-SALE_DT = 1.
<OIUVL_GASDTL_CUR>-ORIG_MP_NO = 1.
<OIUVL_GASDTL_CUR>-WI_OWN_NO = 1.
ENDLOOP.

LOOP AT IT_OIUVL_GASDTL_CUR INTO WA_OIUVL_GASDTL_CUR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIUVL_GASDTL_CUR-WI_INT_TYPE_CD, sy-vline,
WA_OIUVL_GASDTL_CUR-WI_OWN_ISQ_NO, sy-vline,
WA_OIUVL_GASDTL_CUR-MATNR, sy-vline,
WA_OIUVL_GASDTL_CUR-TRNSP_NO, sy-vline,
WA_OIUVL_GASDTL_CUR-TRNSP_REF_NO, sy-vline,
WA_OIUVL_GASDTL_CUR-VL_TYPE_CD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUVL_GASDTL_CUR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUVL_GASDTL_CUR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUVL_GASDTL_CUR INTO WA_OIUVL_GASDTL_CUR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ORIG_MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-ORIG_MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-ORIG_MP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WI_OWN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-WI_OWN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-WI_OWN_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WI_OWN_ISQ_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-WI_OWN_ISQ_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-WI_OWN_ISQ_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-TRNSP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-ENERGY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-ENERGY_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TOT_GR_VL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-TOT_GR_VL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-TOT_GR_VL_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HEAT_VALUE_FCT_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-HEAT_VALUE_FCT_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-HEAT_VALUE_FCT_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PC_CT_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-PC_CT_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-PC_CT_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PC_WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-PC_WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-PC_WL_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PC_WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-PC_WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-PC_WC_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PC_MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUVL_GASDTL_CUR-PC_MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUVL_GASDTL_CUR-PC_MP_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUVL_GASDTL_CUR_STR,
MANDT TYPE STRING,
GASSTMTH_NO TYPE STRING,
SALE_DT TYPE STRING,
ORIG_MP_NO TYPE STRING,
WI_OWN_NO TYPE STRING,
WI_INT_TYPE_CD TYPE STRING,
WI_OWN_ISQ_NO TYPE STRING,
MATNR TYPE STRING,
TRNSP_NO TYPE STRING,
TRNSP_REF_NO TYPE STRING,
VL_TYPE_CD TYPE STRING,
ACTL_ENERGY TYPE STRING,
ENTL_ENERGY TYPE STRING,
ENERGY_U TYPE STRING,
ACTL_GR_VL TYPE STRING,
ENTL_GR_VL TYPE STRING,
TOT_GR_VL_U TYPE STRING,
ACTL_GR_VAL_AM TYPE STRING,
ENTL_GR_VAL_AM TYPE STRING,
GR_VAL_CURR TYPE STRING,
ACT_HEAT_VAL_FCT TYPE STRING,
HEAT_VALUE_FCT_U TYPE STRING,
PC_AMT TYPE STRING,
PC_CURR TYPE STRING,
PC_CT_NO TYPE STRING,
PC_WL_NO TYPE STRING,
PC_WC_NO TYPE STRING,
PC_MP_NO TYPE STRING,
PC_CONDITION TYPE STRING,
KALSM TYPE STRING,
RVRS_ONLY_FL TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUVL_GASDTL_CUR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUVL_GASDTL_CUR_STR-MANDT sy-vline
WA_OIUVL_GASDTL_CUR_STR-GASSTMTH_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-SALE_DT sy-vline
WA_OIUVL_GASDTL_CUR_STR-ORIG_MP_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-WI_OWN_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-WI_INT_TYPE_CD sy-vline
WA_OIUVL_GASDTL_CUR_STR-WI_OWN_ISQ_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-MATNR sy-vline
WA_OIUVL_GASDTL_CUR_STR-TRNSP_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-TRNSP_REF_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-VL_TYPE_CD sy-vline
WA_OIUVL_GASDTL_CUR_STR-ACTL_ENERGY sy-vline
WA_OIUVL_GASDTL_CUR_STR-ENTL_ENERGY sy-vline
WA_OIUVL_GASDTL_CUR_STR-ENERGY_U sy-vline
WA_OIUVL_GASDTL_CUR_STR-ACTL_GR_VL sy-vline
WA_OIUVL_GASDTL_CUR_STR-ENTL_GR_VL sy-vline
WA_OIUVL_GASDTL_CUR_STR-TOT_GR_VL_U sy-vline
WA_OIUVL_GASDTL_CUR_STR-ACTL_GR_VAL_AM sy-vline
WA_OIUVL_GASDTL_CUR_STR-ENTL_GR_VAL_AM sy-vline
WA_OIUVL_GASDTL_CUR_STR-GR_VAL_CURR sy-vline
WA_OIUVL_GASDTL_CUR_STR-ACT_HEAT_VAL_FCT sy-vline
WA_OIUVL_GASDTL_CUR_STR-HEAT_VALUE_FCT_U sy-vline
WA_OIUVL_GASDTL_CUR_STR-PC_AMT sy-vline
WA_OIUVL_GASDTL_CUR_STR-PC_CURR sy-vline
WA_OIUVL_GASDTL_CUR_STR-PC_CT_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-PC_WL_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-PC_WC_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-PC_MP_NO sy-vline
WA_OIUVL_GASDTL_CUR_STR-PC_CONDITION sy-vline
WA_OIUVL_GASDTL_CUR_STR-KALSM sy-vline
WA_OIUVL_GASDTL_CUR_STR-RVRS_ONLY_FL sy-vline
WA_OIUVL_GASDTL_CUR_STR-OIU_CRUSER sy-vline
WA_OIUVL_GASDTL_CUR_STR-OIU_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.