ABAP Select data from SAP table OIUTV_VL_SCN_ALL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUTV_VL_SCN_ALL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUTV_VL_SCN_ALL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIUTV_VL_SCN_ALL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIUTV_VL_SCN_ALL TYPE STANDARD TABLE OF OIUTV_VL_SCN_ALL,
      WA_OIUTV_VL_SCN_ALL TYPE OIUTV_VL_SCN_ALL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIUTV_VL_SCN_ALL> TYPE OIUTV_VL_SCN_ALL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIUTV_VL_SCN_ALL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIUTV_VL_SCN_ALL
  INTO TABLE IT_OIUTV_VL_SCN_ALL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIUTV_VL_SCN_ALL
*  INTO TABLE @DATA(IT_OIUTV_VL_SCN_ALL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIUTV_VL_SCN_ALL INDEX 1 INTO DATA(WA_OIUTV_VL_SCN_ALL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIUTV_VL_SCN_ALL ASSIGNING <OIUTV_VL_SCN_ALL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUTV_VL_SCN_ALL>-MANDT = 1.
<OIUTV_VL_SCN_ALL>-SEQUENCENUMBER = 1.
<OIUTV_VL_SCN_ALL>-DELIVERYNETWORK = 1.
<OIUTV_VL_SCN_ALL>-SALESDATE = 1.
<OIUTV_VL_SCN_ALL>-PRAJOINTVENTURE = 1.
ENDLOOP.

LOOP AT IT_OIUTV_VL_SCN_ALL INTO WA_OIUTV_VL_SCN_ALL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIUTV_VL_SCN_ALL-DIVISIONOFINTEREST, sy-vline,
WA_OIUTV_VL_SCN_ALL-PRACONTRACT, sy-vline,
WA_OIUTV_VL_SCN_ALL-WELL, sy-vline,
WA_OIUTV_VL_SCN_ALL-WELLCOMPLETION, sy-vline,
WA_OIUTV_VL_SCN_ALL-MEASUREMENTPOINT, sy-vline,
WA_OIUTV_VL_SCN_ALL-PRAPRODUCT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUTV_VL_SCN_ALL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUTV_VL_SCN_ALL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUTV_VL_SCN_ALL INTO WA_OIUTV_VL_SCN_ALL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DELIVERYNETWORK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-DELIVERYNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-DELIVERYNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DIVISIONOFINTEREST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-DIVISIONOFINTEREST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-DIVISIONOFINTEREST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRACONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-PRACONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-PRACONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-WELL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-WELL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELLCOMPLETION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-WELLCOMPLETION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-WELLCOMPLETION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MEASUREMENTPOINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-MEASUREMENTPOINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-MEASUREMENTPOINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BASELINEVALNDOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-BASELINEVALNDOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-BASELINEVALNDOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field BASELINEVALNDOCYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-BASELINEVALNDOCYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-BASELINEVALNDOCYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CURRENTVALNDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-CURRENTVALNDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-CURRENTVALNDOCUMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CURRENTVALNDOCUMENTYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_OIUTV_VL_SCN_ALL-CURRENTVALNDOCUMENTYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_VL_SCN_ALL-CURRENTVALNDOCUMENTYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUTV_VL_SCN_ALL_STR,
MANDT TYPE STRING,
SEQUENCENUMBER TYPE STRING,
DELIVERYNETWORK TYPE STRING,
SALESDATE TYPE STRING,
PRAJOINTVENTURE TYPE STRING,
DIVISIONOFINTEREST TYPE STRING,
PRACONTRACT TYPE STRING,
WELL TYPE STRING,
WELLCOMPLETION TYPE STRING,
MEASUREMENTPOINT TYPE STRING,
PRAPRODUCT TYPE STRING,
BOOKINGREVERSALTYPE TYPE STRING,
VOLUMETYPE TYPE STRING,
HEADERSEQUENCENUMBER TYPE STRING,
BASELINEVALNDOC TYPE STRING,
BASELINEVALNDOCYEAR TYPE STRING,
CURRENTVALNDOCUMENT TYPE STRING,
CURRENTVALNDOCUMENTYEAR TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUTV_VL_SCN_ALL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUTV_VL_SCN_ALL_STR-MANDT sy-vline
WA_OIUTV_VL_SCN_ALL_STR-SEQUENCENUMBER sy-vline
WA_OIUTV_VL_SCN_ALL_STR-DELIVERYNETWORK sy-vline
WA_OIUTV_VL_SCN_ALL_STR-SALESDATE sy-vline
WA_OIUTV_VL_SCN_ALL_STR-PRAJOINTVENTURE sy-vline
WA_OIUTV_VL_SCN_ALL_STR-DIVISIONOFINTEREST sy-vline
WA_OIUTV_VL_SCN_ALL_STR-PRACONTRACT sy-vline
WA_OIUTV_VL_SCN_ALL_STR-WELL sy-vline
WA_OIUTV_VL_SCN_ALL_STR-WELLCOMPLETION sy-vline
WA_OIUTV_VL_SCN_ALL_STR-MEASUREMENTPOINT sy-vline
WA_OIUTV_VL_SCN_ALL_STR-PRAPRODUCT sy-vline
WA_OIUTV_VL_SCN_ALL_STR-BOOKINGREVERSALTYPE sy-vline
WA_OIUTV_VL_SCN_ALL_STR-VOLUMETYPE sy-vline
WA_OIUTV_VL_SCN_ALL_STR-HEADERSEQUENCENUMBER sy-vline
WA_OIUTV_VL_SCN_ALL_STR-BASELINEVALNDOC sy-vline
WA_OIUTV_VL_SCN_ALL_STR-BASELINEVALNDOCYEAR sy-vline
WA_OIUTV_VL_SCN_ALL_STR-CURRENTVALNDOCUMENT sy-vline
WA_OIUTV_VL_SCN_ALL_STR-CURRENTVALNDOCUMENTYEAR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.