ABAP Select data from SAP table OIUTV_SB_ENTWC_B into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUTV_SB_ENTWC_B table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUTV_SB_ENTWC_B. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIUTV_SB_ENTWC_B table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIUTV_SB_ENTWC_B TYPE STANDARD TABLE OF OIUTV_SB_ENTWC_B,
      WA_OIUTV_SB_ENTWC_B TYPE OIUTV_SB_ENTWC_B,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIUTV_SB_ENTWC_B> TYPE OIUTV_SB_ENTWC_B.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIUTV_SB_ENTWC_B.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIUTV_SB_ENTWC_B
  INTO TABLE IT_OIUTV_SB_ENTWC_B.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIUTV_SB_ENTWC_B
*  INTO TABLE @DATA(IT_OIUTV_SB_ENTWC_B2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIUTV_SB_ENTWC_B INDEX 1 INTO DATA(WA_OIUTV_SB_ENTWC_B2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIUTV_SB_ENTWC_B ASSIGNING <OIUTV_SB_ENTWC_B>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUTV_SB_ENTWC_B>-MANDT = 1.
<OIUTV_SB_ENTWC_B>-CA_VERSION_ID = 1.
<OIUTV_SB_ENTWC_B>-DN_NO = 1.
<OIUTV_SB_ENTWC_B>-MATNR = 1.
<OIUTV_SB_ENTWC_B>-WL_NO = 1.
ENDLOOP.

LOOP AT IT_OIUTV_SB_ENTWC_B INTO WA_OIUTV_SB_ENTWC_B.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIUTV_SB_ENTWC_B-WC_NO, sy-vline,
WA_OIUTV_SB_ENTWC_B-BUKRS, sy-vline,
WA_OIUTV_SB_ENTWC_B-VNAME, sy-vline,
WA_OIUTV_SB_ENTWC_B-DOI_NO, sy-vline,
WA_OIUTV_SB_ENTWC_B-SA_DT, sy-vline,
WA_OIUTV_SB_ENTWC_B-FREQ_CD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUTV_SB_ENTWC_B you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUTV_SB_ENTWC_B TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUTV_SB_ENTWC_B INTO WA_OIUTV_SB_ENTWC_B. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-DN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-DN_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-WL_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-WC_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOI_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-DOI_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-DOI_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-OWN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-OWN_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWN_ISQ_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-OWN_ISQ_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-OWN_ISQ_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MK_REP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-MK_REP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-MK_REP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MK_REP_ISQ_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-MK_REP_ISQ_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-MK_REP_ISQ_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-VOL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-VOL_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIUTV_SB_ENTWC_B-ENERGY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIUTV_SB_ENTWC_B-ENERGY_U.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUTV_SB_ENTWC_B_STR,
MANDT TYPE STRING,
CA_VERSION_ID TYPE STRING,
DN_NO TYPE STRING,
MATNR TYPE STRING,
WL_NO TYPE STRING,
WC_NO TYPE STRING,
BUKRS TYPE STRING,
VNAME TYPE STRING,
DOI_NO TYPE STRING,
SA_DT TYPE STRING,
FREQ_CD TYPE STRING,
VT_CD TYPE STRING,
OWN_NO TYPE STRING,
OWN_INT_TYPE_CD TYPE STRING,
OWN_ISQ_NO TYPE STRING,
MK_REP_NO TYPE STRING,
MK_REP_ISQ_NO TYPE STRING,
VOL_U TYPE STRING,
ENTL_VOL TYPE STRING,
ADJ_ENTL_VOL TYPE STRING,
ENERGY_U TYPE STRING,
ENTL_ENERGY TYPE STRING,
ADJ_ENTL_ENERGY TYPE STRING,
GRI_PC TYPE STRING,
ADJ_GRI_PC TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,
KW_OWN_CD TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUTV_SB_ENTWC_B_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUTV_SB_ENTWC_B_STR-MANDT sy-vline
WA_OIUTV_SB_ENTWC_B_STR-CA_VERSION_ID sy-vline
WA_OIUTV_SB_ENTWC_B_STR-DN_NO sy-vline
WA_OIUTV_SB_ENTWC_B_STR-MATNR sy-vline
WA_OIUTV_SB_ENTWC_B_STR-WL_NO sy-vline
WA_OIUTV_SB_ENTWC_B_STR-WC_NO sy-vline
WA_OIUTV_SB_ENTWC_B_STR-BUKRS sy-vline
WA_OIUTV_SB_ENTWC_B_STR-VNAME sy-vline
WA_OIUTV_SB_ENTWC_B_STR-DOI_NO sy-vline
WA_OIUTV_SB_ENTWC_B_STR-SA_DT sy-vline
WA_OIUTV_SB_ENTWC_B_STR-FREQ_CD sy-vline
WA_OIUTV_SB_ENTWC_B_STR-VT_CD sy-vline
WA_OIUTV_SB_ENTWC_B_STR-OWN_NO sy-vline
WA_OIUTV_SB_ENTWC_B_STR-OWN_INT_TYPE_CD sy-vline
WA_OIUTV_SB_ENTWC_B_STR-OWN_ISQ_NO sy-vline
WA_OIUTV_SB_ENTWC_B_STR-MK_REP_NO sy-vline
WA_OIUTV_SB_ENTWC_B_STR-MK_REP_ISQ_NO sy-vline
WA_OIUTV_SB_ENTWC_B_STR-VOL_U sy-vline
WA_OIUTV_SB_ENTWC_B_STR-ENTL_VOL sy-vline
WA_OIUTV_SB_ENTWC_B_STR-ADJ_ENTL_VOL sy-vline
WA_OIUTV_SB_ENTWC_B_STR-ENERGY_U sy-vline
WA_OIUTV_SB_ENTWC_B_STR-ENTL_ENERGY sy-vline
WA_OIUTV_SB_ENTWC_B_STR-ADJ_ENTL_ENERGY sy-vline
WA_OIUTV_SB_ENTWC_B_STR-GRI_PC sy-vline
WA_OIUTV_SB_ENTWC_B_STR-ADJ_GRI_PC sy-vline
WA_OIUTV_SB_ENTWC_B_STR-OIU_CRUSER sy-vline
WA_OIUTV_SB_ENTWC_B_STR-OIU_TIMESTAMP sy-vline
WA_OIUTV_SB_ENTWC_B_STR-KW_OWN_CD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.