ABAP Select data from SAP table OIUH_AFRVTRBBYQBE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIUH_AFRVTRBBYQBE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIUH_AFRVTRBBYQBE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OIUH_AFRVTRBBYQBE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OIUH_AFRVTRBBYQBE TYPE STANDARD TABLE OF OIUH_AFRVTRBBYQBE, WA_OIUH_AFRVTRBBYQBE TYPE OIUH_AFRVTRBBYQBE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OIUH_AFRVTRBBYQBE> TYPE OIUH_AFRVTRBBYQBE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OIUH_AFRVTRBBYQBE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OIUH_AFRVTRBBYQBE INTO TABLE IT_OIUH_AFRVTRBBYQBE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OIUH_AFRVTRBBYQBE * INTO TABLE @DATA(IT_OIUH_AFRVTRBBYQBE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OIUH_AFRVTRBBYQBE INDEX 1 INTO DATA(WA_OIUH_AFRVTRBBYQBE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OIUH_AFRVTRBBYQBE ASSIGNING <OIUH_AFRVTRBBYQBE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIUH_AFRVTRBBYQBE>-C_RB_SYS_NO = 1.
<OIUH_AFRVTRBBYQBE>-C_BA_NM_1 = 1.
<OIUH_AFRVTRBBYQBE>-C_RB_PU_NO = 1.
<OIUH_AFRVTRBBYQBE>-C_RB_PU_SEQ_NO = 1.
<OIUH_AFRVTRBBYQBE>-C_MP_MP_NO = 1.
ENDLOOP. LOOP AT IT_OIUH_AFRVTRBBYQBE INTO WA_OIUH_AFRVTRBBYQBE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OIUH_AFRVTRBBYQBE-C_MP_MP_DE, sy-vline,
WA_OIUH_AFRVTRBBYQBE-C_DI_DI_NM, sy-vline,
WA_OIUH_AFRVTRBBYQBE-C_RB_ARMT_LVL_1_CD, sy-vline,
WA_OIUH_AFRVTRBBYQBE-C_RB_ARMT_LVL_2_CD, sy-vline,
WA_OIUH_AFRVTRBBYQBE-C_A_TT_ELEM_DE, sy-vline,
WA_OIUH_AFRVTRBBYQBE-C_RB_PD_CD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIUH_AFRVTRBBYQBE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIUH_AFRVTRBBYQBE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIUH_AFRVTRBBYQBE INTO WA_OIUH_AFRVTRBBYQBE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIUH_AFRVTRBBYQBE_STR,
C_RB_SYS_NO TYPE STRING,
C_BA_NM_1 TYPE STRING,
C_RB_PU_NO TYPE STRING,
C_RB_PU_SEQ_NO TYPE STRING,
C_MP_MP_NO TYPE STRING,
C_MP_MP_DE TYPE STRING,
C_DI_DI_NM TYPE STRING,
C_RB_ARMT_LVL_1_CD TYPE STRING,
C_RB_ARMT_LVL_2_CD TYPE STRING,
C_A_TT_ELEM_DE TYPE STRING,
C_RB_PD_CD TYPE STRING,
C_RB_PROD_MO_DT TYPE STRING,
C_RB_CUR_BAL_AM TYPE STRING,
C_B_TT_ELEM_DE TYPE STRING,
C_RB_RESP_NO TYPE STRING,
C_RB_VER_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIUH_AFRVTRBBYQBE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_SYS_NO sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_BA_NM_1 sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_PU_NO sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_PU_SEQ_NO sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_MP_MP_NO sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_MP_MP_DE sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_DI_DI_NM sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_ARMT_LVL_1_CD sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_ARMT_LVL_2_CD sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_A_TT_ELEM_DE sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_PD_CD sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_PROD_MO_DT sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_CUR_BAL_AM sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_B_TT_ELEM_DE sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_RESP_NO sy-vline
WA_OIUH_AFRVTRBBYQBE_STR-C_RB_VER_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.