ABAP Select data from SAP table OIU_PR_MP_MASTER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIU_PR_MP_MASTER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIU_PR_MP_MASTER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIU_PR_MP_MASTER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIU_PR_MP_MASTER TYPE STANDARD TABLE OF OIU_PR_MP_MASTER,
      WA_OIU_PR_MP_MASTER TYPE OIU_PR_MP_MASTER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIU_PR_MP_MASTER> TYPE OIU_PR_MP_MASTER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIU_PR_MP_MASTER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIU_PR_MP_MASTER
  INTO TABLE IT_OIU_PR_MP_MASTER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIU_PR_MP_MASTER
*  INTO TABLE @DATA(IT_OIU_PR_MP_MASTER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIU_PR_MP_MASTER INDEX 1 INTO DATA(WA_OIU_PR_MP_MASTER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIU_PR_MP_MASTER ASSIGNING <OIU_PR_MP_MASTER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIU_PR_MP_MASTER>-MP_NO = 1.
<OIU_PR_MP_MASTER>-MP_DESC = 1.
<OIU_PR_MP_MASTER>-MP_SHORT_TXT = 1.
<OIU_PR_MP_MASTER>-MP_TYPE = 1.
<OIU_PR_MP_MASTER>-UOM_GRP = 1.
ENDLOOP.

LOOP AT IT_OIU_PR_MP_MASTER INTO WA_OIU_PR_MP_MASTER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIU_PR_MP_MASTER-MTR_CLS, sy-vline,
WA_OIU_PR_MP_MASTER-COMPANY_CODE, sy-vline,
WA_OIU_PR_MP_MASTER-COUNTRY, sy-vline,
WA_OIU_PR_MP_MASTER-STATE, sy-vline,
WA_OIU_PR_MP_MASTER-SEC_GEO_LOC, sy-vline,
WA_OIU_PR_MP_MASTER-LATITUDE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIU_PR_MP_MASTER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIU_PR_MP_MASTER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIU_PR_MP_MASTER INTO WA_OIU_PR_MP_MASTER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIU_PR_MP_MASTER-MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_PR_MP_MASTER-MP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit OIUNM, internal->external for field MP_DESC CALL FUNCTION 'CONVERSION_EXIT_OIUNM_OUTPUT' EXPORTING input = WA_OIU_PR_MP_MASTER-MP_DESC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIU_PR_MP_MASTER-MP_DESC.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIU_PR_MP_MASTER_STR,
MP_NO TYPE STRING,
MP_DESC TYPE STRING,
MP_SHORT_TXT TYPE STRING,
MP_TYPE TYPE STRING,
UOM_GRP TYPE STRING,
MTR_CLS TYPE STRING,
COMPANY_CODE TYPE STRING,
COUNTRY TYPE STRING,
STATE TYPE STRING,
SEC_GEO_LOC TYPE STRING,
LATITUDE TYPE STRING,
LAT_DIR TYPE STRING,
LONGITUDE TYPE STRING,
LONG_DIR TYPE STRING,
EFF_FROM_DT TYPE STRING,
EFF_TO_DT TYPE STRING,
INACTIVE_FL TYPE STRING,
OPER_FL TYPE STRING,
SAT_DRY_CD TYPE STRING,
PLT_INLET_FL TYPE STRING,
STRM_TYPE_CD TYPE STRING,
STRM_DFLT_FL TYPE STRING,
RLF_USAGE_FL TYPE STRING,
TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIU_PR_MP_MASTER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIU_PR_MP_MASTER_STR-MP_NO sy-vline
WA_OIU_PR_MP_MASTER_STR-MP_DESC sy-vline
WA_OIU_PR_MP_MASTER_STR-MP_SHORT_TXT sy-vline
WA_OIU_PR_MP_MASTER_STR-MP_TYPE sy-vline
WA_OIU_PR_MP_MASTER_STR-UOM_GRP sy-vline
WA_OIU_PR_MP_MASTER_STR-MTR_CLS sy-vline
WA_OIU_PR_MP_MASTER_STR-COMPANY_CODE sy-vline
WA_OIU_PR_MP_MASTER_STR-COUNTRY sy-vline
WA_OIU_PR_MP_MASTER_STR-STATE sy-vline
WA_OIU_PR_MP_MASTER_STR-SEC_GEO_LOC sy-vline
WA_OIU_PR_MP_MASTER_STR-LATITUDE sy-vline
WA_OIU_PR_MP_MASTER_STR-LAT_DIR sy-vline
WA_OIU_PR_MP_MASTER_STR-LONGITUDE sy-vline
WA_OIU_PR_MP_MASTER_STR-LONG_DIR sy-vline
WA_OIU_PR_MP_MASTER_STR-EFF_FROM_DT sy-vline
WA_OIU_PR_MP_MASTER_STR-EFF_TO_DT sy-vline
WA_OIU_PR_MP_MASTER_STR-INACTIVE_FL sy-vline
WA_OIU_PR_MP_MASTER_STR-OPER_FL sy-vline
WA_OIU_PR_MP_MASTER_STR-SAT_DRY_CD sy-vline
WA_OIU_PR_MP_MASTER_STR-PLT_INLET_FL sy-vline
WA_OIU_PR_MP_MASTER_STR-STRM_TYPE_CD sy-vline
WA_OIU_PR_MP_MASTER_STR-STRM_DFLT_FL sy-vline
WA_OIU_PR_MP_MASTER_STR-RLF_USAGE_FL sy-vline
WA_OIU_PR_MP_MASTER_STR-TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.