ABAP Select data from SAP table OIO_OIGV_VMIS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIO_OIGV_VMIS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIO_OIGV_VMIS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIO_OIGV_VMIS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIO_OIGV_VMIS TYPE STANDARD TABLE OF OIO_OIGV_VMIS,
      WA_OIO_OIGV_VMIS TYPE OIO_OIGV_VMIS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIO_OIGV_VMIS> TYPE OIO_OIGV_VMIS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIO_OIGV_VMIS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIO_OIGV_VMIS
  INTO TABLE IT_OIO_OIGV_VMIS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIO_OIGV_VMIS
*  INTO TABLE @DATA(IT_OIO_OIGV_VMIS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIO_OIGV_VMIS INDEX 1 INTO DATA(WA_OIO_OIGV_VMIS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIO_OIGV_VMIS ASSIGNING <OIO_OIGV_VMIS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIO_OIGV_VMIS>-AVERAGE_SPEED = 1.
<OIO_OIGV_VMIS>-AVR_SPEED_UOM = 1.
<OIO_OIGV_VMIS>-DECK_CAPACITY = 1.
<OIO_OIGV_VMIS>-DECK_CAP_UOM = 1.
<OIO_OIGV_VMIS>-ARRIVAL_BUFFER = 1.
ENDLOOP.

LOOP AT IT_OIO_OIGV_VMIS INTO WA_OIO_OIGV_VMIS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIO_OIGV_VMIS-DEPARTURE_BUFFER, sy-vline,
WA_OIO_OIGV_VMIS-VEH_MAIL, sy-vline,
WA_OIO_OIGV_VMIS-VEH_PHONE, sy-vline,
ENDLOOP. *Add any further fields from structure WA_OIO_OIGV_VMIS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIO_OIGV_VMIS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIO_OIGV_VMIS INTO WA_OIO_OIGV_VMIS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field AVR_SPEED_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIO_OIGV_VMIS-AVR_SPEED_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIO_OIGV_VMIS-AVR_SPEED_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DECK_CAP_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIO_OIGV_VMIS-DECK_CAP_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIO_OIGV_VMIS-DECK_CAP_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRN, internal->external for field ARRIVAL_BUFFER CALL FUNCTION 'CONVERSION_EXIT_TSTRN_OUTPUT' EXPORTING input = WA_OIO_OIGV_VMIS-ARRIVAL_BUFFER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIO_OIGV_VMIS-ARRIVAL_BUFFER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRN, internal->external for field DEPARTURE_BUFFER CALL FUNCTION 'CONVERSION_EXIT_TSTRN_OUTPUT' EXPORTING input = WA_OIO_OIGV_VMIS-DEPARTURE_BUFFER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIO_OIGV_VMIS-DEPARTURE_BUFFER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field VEH_MAIL CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_OIO_OIGV_VMIS-VEH_MAIL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIO_OIGV_VMIS-VEH_MAIL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIO_OIGV_VMIS_STR,
AVERAGE_SPEED TYPE STRING,
AVR_SPEED_UOM TYPE STRING,
DECK_CAPACITY TYPE STRING,
DECK_CAP_UOM TYPE STRING,
ARRIVAL_BUFFER TYPE STRING,
DEPARTURE_BUFFER TYPE STRING,
VEH_MAIL TYPE STRING,
VEH_PHONE TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIO_OIGV_VMIS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIO_OIGV_VMIS_STR-AVERAGE_SPEED sy-vline
WA_OIO_OIGV_VMIS_STR-AVR_SPEED_UOM sy-vline
WA_OIO_OIGV_VMIS_STR-DECK_CAPACITY sy-vline
WA_OIO_OIGV_VMIS_STR-DECK_CAP_UOM sy-vline
WA_OIO_OIGV_VMIS_STR-ARRIVAL_BUFFER sy-vline
WA_OIO_OIGV_VMIS_STR-DEPARTURE_BUFFER sy-vline
WA_OIO_OIGV_VMIS_STR-VEH_MAIL sy-vline
WA_OIO_OIGV_VMIS_STR-VEH_PHONE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.