ABAP Select data from SAP table OIL_OIH_HTYPE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIL_OIH_HTYPE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIL_OIH_HTYPE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIL_OIH_HTYPE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIL_OIH_HTYPE TYPE STANDARD TABLE OF OIL_OIH_HTYPE,
      WA_OIL_OIH_HTYPE TYPE OIL_OIH_HTYPE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIL_OIH_HTYPE> TYPE OIL_OIH_HTYPE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIL_OIH_HTYPE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIL_OIH_HTYPE
  INTO TABLE IT_OIL_OIH_HTYPE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIL_OIH_HTYPE
*  INTO TABLE @DATA(IT_OIL_OIH_HTYPE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIL_OIH_HTYPE INDEX 1 INTO DATA(WA_OIL_OIH_HTYPE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIL_OIH_HTYPE ASSIGNING <OIL_OIH_HTYPE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIL_OIH_HTYPE>-FOLQTY = 1.
<OIL_OIH_HTYPE>-WERKS_CC = 1.
<OIL_OIH_HTYPE>-LGORT_CC = 1.
<OIL_OIH_HTYPE>-OITAXGRP_CC = 1.
<OIL_OIH_HTYPE>-OIHANTYP_CC = 1.
ENDLOOP.

LOOP AT IT_OIL_OIH_HTYPE INTO WA_OIL_OIH_HTYPE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIL_OIH_HTYPE-BWTAR_CC, sy-vline,
WA_OIL_OIH_HTYPE-RESWK_CC, sy-vline,
WA_OIL_OIH_HTYPE-RESLO_CC, sy-vline,
WA_OIL_OIH_HTYPE-OITAXGRP_GI_CC, sy-vline,
WA_OIL_OIH_HTYPE-OIHANTYP_GI_CC, sy-vline,
WA_OIL_OIH_HTYPE-OIUMBAR_CC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIL_OIH_HTYPE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIL_OIH_HTYPE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIL_OIH_HTYPE INTO WA_OIL_OIH_HTYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIL_OIH_HTYPE_STR,
FOLQTY TYPE STRING,
WERKS_CC TYPE STRING,
LGORT_CC TYPE STRING,
OITAXGRP_CC TYPE STRING,
OIHANTYP_CC TYPE STRING,
BWTAR_CC TYPE STRING,
RESWK_CC TYPE STRING,
RESLO_CC TYPE STRING,
OITAXGRP_GI_CC TYPE STRING,
OIHANTYP_GI_CC TYPE STRING,
OIUMBAR_CC TYPE STRING,
DO_IM_EX TYPE STRING,
ERRV1 TYPE STRING,
ERRV2 TYPE STRING,
ERRV3 TYPE STRING,
ERRV4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIL_OIH_HTYPE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIL_OIH_HTYPE_STR-FOLQTY sy-vline
WA_OIL_OIH_HTYPE_STR-WERKS_CC sy-vline
WA_OIL_OIH_HTYPE_STR-LGORT_CC sy-vline
WA_OIL_OIH_HTYPE_STR-OITAXGRP_CC sy-vline
WA_OIL_OIH_HTYPE_STR-OIHANTYP_CC sy-vline
WA_OIL_OIH_HTYPE_STR-BWTAR_CC sy-vline
WA_OIL_OIH_HTYPE_STR-RESWK_CC sy-vline
WA_OIL_OIH_HTYPE_STR-RESLO_CC sy-vline
WA_OIL_OIH_HTYPE_STR-OITAXGRP_GI_CC sy-vline
WA_OIL_OIH_HTYPE_STR-OIHANTYP_GI_CC sy-vline
WA_OIL_OIH_HTYPE_STR-OIUMBAR_CC sy-vline
WA_OIL_OIH_HTYPE_STR-DO_IM_EX sy-vline
WA_OIL_OIH_HTYPE_STR-ERRV1 sy-vline
WA_OIL_OIH_HTYPE_STR-ERRV2 sy-vline
WA_OIL_OIH_HTYPE_STR-ERRV3 sy-vline
WA_OIL_OIH_HTYPE_STR-ERRV4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.