ABAP Select data from SAP table OIJ02_DS_3WP_TRANS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIJ02_DS_3WP_TRANS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIJ02_DS_3WP_TRANS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIJ02_DS_3WP_TRANS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIJ02_DS_3WP_TRANS TYPE STANDARD TABLE OF OIJ02_DS_3WP_TRANS,
      WA_OIJ02_DS_3WP_TRANS TYPE OIJ02_DS_3WP_TRANS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIJ02_DS_3WP_TRANS> TYPE OIJ02_DS_3WP_TRANS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIJ02_DS_3WP_TRANS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIJ02_DS_3WP_TRANS
  INTO TABLE IT_OIJ02_DS_3WP_TRANS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIJ02_DS_3WP_TRANS
*  INTO TABLE @DATA(IT_OIJ02_DS_3WP_TRANS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIJ02_DS_3WP_TRANS INDEX 1 INTO DATA(WA_OIJ02_DS_3WP_TRANS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIJ02_DS_3WP_TRANS ASSIGNING <OIJ02_DS_3WP_TRANS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIJ02_DS_3WP_TRANS>-ITEMID = 1.
<OIJ02_DS_3WP_TRANS>-VEH_ID = 1.
<OIJ02_DS_3WP_TRANS>-VEHICLE = 1.
<OIJ02_DS_3WP_TRANS>-DOCNR_FCC = 1.
<OIJ02_DS_3WP_TRANS>-VAL_FROM = 1.
ENDLOOP.

LOOP AT IT_OIJ02_DS_3WP_TRANS INTO WA_OIJ02_DS_3WP_TRANS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIJ02_DS_3WP_TRANS-VAL_TO, sy-vline,
WA_OIJ02_DS_3WP_TRANS-DOCITM_FCC, sy-vline,
WA_OIJ02_DS_3WP_TRANS-DOCIND_FCC, sy-vline,
WA_OIJ02_DS_3WP_TRANS-OWN_FLAG, sy-vline,
WA_OIJ02_DS_3WP_TRANS-SINGLE_VOY, sy-vline,
WA_OIJ02_DS_3WP_TRANS-CRLOCID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIJ02_DS_3WP_TRANS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIJ02_DS_3WP_TRANS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIJ02_DS_3WP_TRANS INTO WA_OIJ02_DS_3WP_TRANS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VEHICLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ02_DS_3WP_TRANS-VEHICLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ02_DS_3WP_TRANS-VEHICLE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCNR_FCC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ02_DS_3WP_TRANS-DOCNR_FCC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ02_DS_3WP_TRANS-DOCNR_FCC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VEH_CAP_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OIJ02_DS_3WP_TRANS-VEH_CAP_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ02_DS_3WP_TRANS-VEH_CAP_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FLTTNOMTK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIJ02_DS_3WP_TRANS-FLTTNOMTK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIJ02_DS_3WP_TRANS-FLTTNOMTK.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIJ02_DS_3WP_TRANS_STR,
ITEMID TYPE STRING,
VEH_ID TYPE STRING,
VEHICLE TYPE STRING,
DOCNR_FCC TYPE STRING,
VAL_FROM TYPE STRING,
VAL_TO TYPE STRING,
DOCITM_FCC TYPE STRING,
DOCIND_FCC TYPE STRING,
OWN_FLAG TYPE STRING,
SINGLE_VOY TYPE STRING,
CRLOCID TYPE STRING,
VEH_AVAIL_FR_DATE TYPE STRING,
VEH_AVAIL_TO_DATE TYPE STRING,
CRNOMNR TYPE STRING,
NXLOCID TYPE STRING,
MAX_CAP TYPE STRING,
REM_CAP TYPE STRING,
VEH_CAP_UOM TYPE STRING,
VEH_TYPE TYPE STRING,
TOL_MAX TYPE STRING,
TOL_MIN TYPE STRING,
FLTTNOMTK TYPE STRING,
LP1 TYPE STRING,
LP1_ETA TYPE STRING,
LP1_ETD TYPE STRING,
LP_KNOT1 TYPE STRING,
DP1 TYPE STRING,
DP1_ETA TYPE STRING,
DP_KNOT2 TYPE STRING,
DP2 TYPE STRING,
DP2_ETA TYPE STRING,
DP_KNOT3 TYPE STRING,
DP3 TYPE STRING,
DP3_ETA TYPE STRING,
DP_KNOT4 TYPE STRING,
KNOT1_TXT TYPE STRING,
KNOT2_TXT TYPE STRING,
KNOT3_TXT TYPE STRING,
KNOT4_TXT TYPE STRING,
FREIGHT_VENDOR TYPE STRING,
FEU TYPE STRING,
FTU TYPE STRING,
BFEU TYPE STRING,
BTEU TYPE STRING,
NMVEHICLE_TXT TYPE STRING,
CONSUMED_FLAG TYPE STRING,
CELL_DESIGN TYPE STRING,
TEXTVIEW_SEM_COLOR TYPE STRING,
TEXTVIEW_DESIGN TYPE STRING,
LOCK_DB TYPE STRING,
CELL_DESIGN_ALL TYPE STRING,
CELL_DESIGN_LTA TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIJ02_DS_3WP_TRANS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-ITEMID sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-VEH_ID sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-VEHICLE sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DOCNR_FCC sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-VAL_FROM sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-VAL_TO sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DOCITM_FCC sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DOCIND_FCC sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-OWN_FLAG sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-SINGLE_VOY sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-CRLOCID sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-VEH_AVAIL_FR_DATE sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-VEH_AVAIL_TO_DATE sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-CRNOMNR sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-NXLOCID sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-MAX_CAP sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-REM_CAP sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-VEH_CAP_UOM sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-VEH_TYPE sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-TOL_MAX sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-TOL_MIN sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-FLTTNOMTK sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-LP1 sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-LP1_ETA sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-LP1_ETD sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-LP_KNOT1 sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DP1 sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DP1_ETA sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DP_KNOT2 sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DP2 sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DP2_ETA sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DP_KNOT3 sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DP3 sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DP3_ETA sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-DP_KNOT4 sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-KNOT1_TXT sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-KNOT2_TXT sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-KNOT3_TXT sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-KNOT4_TXT sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-FREIGHT_VENDOR sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-FEU sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-FTU sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-BFEU sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-BTEU sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-NMVEHICLE_TXT sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-CONSUMED_FLAG sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-CELL_DESIGN sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-TEXTVIEW_SEM_COLOR sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-TEXTVIEW_DESIGN sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-LOCK_DB sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-CELL_DESIGN_ALL sy-vline
WA_OIJ02_DS_3WP_TRANS_STR-CELL_DESIGN_LTA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.