ABAP Select data from SAP table OIBEA8 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIBEA8 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIBEA8. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIBEA8 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIBEA8 TYPE STANDARD TABLE OF OIBEA8,
      WA_OIBEA8 TYPE OIBEA8,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIBEA8> TYPE OIBEA8.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIBEA8.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIBEA8
  INTO TABLE IT_OIBEA8.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIBEA8
*  INTO TABLE @DATA(IT_OIBEA82).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIBEA8 INDEX 1 INTO DATA(WA_OIBEA82).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIBEA8 ASSIGNING <OIBEA8>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIBEA8>-CODE = 1.
<OIBEA8>-HYDROCARBMOLFRAC = 1.
<OIBEA8>-AGASTDTMP = 1.
<OIBEA8>-AGASTDPRS = 1.
<OIBEA8>-COMPRESSIONOBS = 1.
ENDLOOP.

LOOP AT IT_OIBEA8 INTO WA_OIBEA8.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIBEA8-COMPRESSIONBASE, sy-vline,
WA_OIBEA8-COMPRESSIONUSBASE, sy-vline,
WA_OIBEA8-FLDICH, sy-vline,
WA_OIBEA8-BDICH, sy-vline,
WA_OIBEA8-USDICH, sy-vline,
WA_OIBEA8-SUPERCOMP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIBEA8 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIBEA8 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIBEA8 INTO WA_OIBEA8. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIBEA8_STR,
CODE TYPE STRING,
HYDROCARBMOLFRAC TYPE STRING,
AGASTDTMP TYPE STRING,
AGASTDPRS TYPE STRING,
COMPRESSIONOBS TYPE STRING,
COMPRESSIONBASE TYPE STRING,
COMPRESSIONUSBASE TYPE STRING,
FLDICH TYPE STRING,
BDICH TYPE STRING,
USDICH TYPE STRING,
SUPERCOMP TYPE STRING,
MOLWEIGHT TYPE STRING,
RELBDICH TYPE STRING,
RELUSDICH TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIBEA8_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIBEA8_STR-CODE sy-vline
WA_OIBEA8_STR-HYDROCARBMOLFRAC sy-vline
WA_OIBEA8_STR-AGASTDTMP sy-vline
WA_OIBEA8_STR-AGASTDPRS sy-vline
WA_OIBEA8_STR-COMPRESSIONOBS sy-vline
WA_OIBEA8_STR-COMPRESSIONBASE sy-vline
WA_OIBEA8_STR-COMPRESSIONUSBASE sy-vline
WA_OIBEA8_STR-FLDICH sy-vline
WA_OIBEA8_STR-BDICH sy-vline
WA_OIBEA8_STR-USDICH sy-vline
WA_OIBEA8_STR-SUPERCOMP sy-vline
WA_OIBEA8_STR-MOLWEIGHT sy-vline
WA_OIBEA8_STR-RELBDICH sy-vline
WA_OIBEA8_STR-RELUSDICH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.