ABAP Select data from SAP table OIA06 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OIA06 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OIA06. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OIA06 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OIA06 TYPE STANDARD TABLE OF OIA06,
      WA_OIA06 TYPE OIA06,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OIA06> TYPE OIA06.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OIA06.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OIA06
  INTO TABLE IT_OIA06.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OIA06
*  INTO TABLE @DATA(IT_OIA062).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OIA06 INDEX 1 INTO DATA(WA_OIA062).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OIA06 ASSIGNING <OIA06>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OIA06>-MANDT = 1.
<OIA06>-BUKRS = 1.
<OIA06>-EBELN = 1.
<OIA06>-EBELP = 1.
<OIA06>-SUBITM = 1.
ENDLOOP.

LOOP AT IT_OIA06 INTO WA_OIA06.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OIA06-SEQENT, sy-vline,
WA_OIA06-SCHDDT, sy-vline,
WA_OIA06-SMENGE, sy-vline,
WA_OIA06-INTQTY, sy-vline,
WA_OIA06-RECQTY, sy-vline,
WA_OIA06-ENTLU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OIA06 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OIA06 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OIA06 INTO WA_OIA06. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OIA06-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OIA06-EBELN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OIA06_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
SUBITM TYPE STRING,
SEQENT TYPE STRING,
SCHDDT TYPE STRING,
SMENGE TYPE STRING,
INTQTY TYPE STRING,
RECQTY TYPE STRING,
ENTLU TYPE STRING,
AUTIND TYPE STRING,
_DATAAGING TYPE STRING,
/DMBE/CLOSEDINDICATOR TYPE STRING,
/DMBE/TLINK TYPE STRING,
/DMBE/CYCLE_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_OIA06_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OIA06_STR-MANDT sy-vline
WA_OIA06_STR-BUKRS sy-vline
WA_OIA06_STR-EBELN sy-vline
WA_OIA06_STR-EBELP sy-vline
WA_OIA06_STR-SUBITM sy-vline
WA_OIA06_STR-SEQENT sy-vline
WA_OIA06_STR-SCHDDT sy-vline
WA_OIA06_STR-SMENGE sy-vline
WA_OIA06_STR-INTQTY sy-vline
WA_OIA06_STR-RECQTY sy-vline
WA_OIA06_STR-ENTLU sy-vline
WA_OIA06_STR-AUTIND sy-vline
WA_OIA06_STR-_DATAAGING sy-vline
WA_OIA06_STR-/DMBE/CLOSEDINDICATOR sy-vline
WA_OIA06_STR-/DMBE/TLINK sy-vline
WA_OIA06_STR-/DMBE/CYCLE_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.