ABAP Select data from SAP table OI0BW_OIAQS_S_NEW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OI0BW_OIAQS_S_NEW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OI0BW_OIAQS_S_NEW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OI0BW_OIAQS_S_NEW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OI0BW_OIAQS_S_NEW TYPE STANDARD TABLE OF OI0BW_OIAQS_S_NEW,
      WA_OI0BW_OIAQS_S_NEW TYPE OI0BW_OIAQS_S_NEW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OI0BW_OIAQS_S_NEW> TYPE OI0BW_OIAQS_S_NEW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OI0BW_OIAQS_S_NEW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OI0BW_OIAQS_S_NEW
  INTO TABLE IT_OI0BW_OIAQS_S_NEW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OI0BW_OIAQS_S_NEW
*  INTO TABLE @DATA(IT_OI0BW_OIAQS_S_NEW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OI0BW_OIAQS_S_NEW INDEX 1 INTO DATA(WA_OI0BW_OIAQS_S_NEW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OI0BW_OIAQS_S_NEW ASSIGNING <OI0BW_OIAQS_S_NEW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OI0BW_OIAQS_S_NEW>-BUKRS = 1.
<OI0BW_OIAQS_S_NEW>-EXGNUM = 1.
<OI0BW_OIAQS_S_NEW>-EXGPTR = 1.
<OI0BW_OIAQS_S_NEW>-VBELN = 1.
<OI0BW_OIAQS_S_NEW>-POSNR = 1.
ENDLOOP.

LOOP AT IT_OI0BW_OIAQS_S_NEW INTO WA_OI0BW_OIAQS_S_NEW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OI0BW_OIAQS_S_NEW-EBELN, sy-vline,
WA_OI0BW_OIAQS_S_NEW-EBELP, sy-vline,
WA_OI0BW_OIAQS_S_NEW-SUBITM, sy-vline,
WA_OI0BW_OIAQS_S_NEW-SEQENT, sy-vline,
WA_OI0BW_OIAQS_S_NEW-CIND, sy-vline,
WA_OI0BW_OIAQS_S_NEW-MATNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OI0BW_OIAQS_S_NEW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OI0BW_OIAQS_S_NEW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OI0BW_OIAQS_S_NEW INTO WA_OI0BW_OIAQS_S_NEW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EXGNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OI0BW_OIAQS_S_NEW-EXGNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OI0BW_OIAQS_S_NEW-EXGNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXGPTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OI0BW_OIAQS_S_NEW-EXGPTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OI0BW_OIAQS_S_NEW-EXGPTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OI0BW_OIAQS_S_NEW-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OI0BW_OIAQS_S_NEW-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OI0BW_OIAQS_S_NEW-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OI0BW_OIAQS_S_NEW-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OI0BW_OIAQS_S_NEW-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OI0BW_OIAQS_S_NEW-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OI0BW_OIAQS_S_NEW-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OI0BW_OIAQS_S_NEW-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OI0BW_OIAQS_S_NEW_STR,
BUKRS TYPE STRING,
EXGNUM TYPE STRING,
EXGPTR TYPE STRING,
VBELN TYPE STRING,
POSNR TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
SUBITM TYPE STRING,
SEQENT TYPE STRING,
CIND TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
SCHDDT TYPE STRING,
SMENGE TYPE STRING,
INTQTY TYPE STRING,
RECQTY TYPE STRING,
MEINS TYPE STRING,
ENTLU TYPE STRING,
SPLIT TYPE STRING,
MOD TYPE STRING,
OIPRIOR TYPE STRING,
UPDMOD TYPE STRING,END OF T_EKKO_STR. DATA: WA_OI0BW_OIAQS_S_NEW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-BUKRS sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-EXGNUM sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-EXGPTR sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-VBELN sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-POSNR sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-EBELN sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-EBELP sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-SUBITM sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-SEQENT sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-CIND sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-MATNR sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-WERKS sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-SCHDDT sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-SMENGE sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-INTQTY sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-RECQTY sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-MEINS sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-ENTLU sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-SPLIT sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-MOD sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-OIPRIOR sy-vline
WA_OI0BW_OIAQS_S_NEW_STR-UPDMOD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.