ABAP Select data from SAP table OBOM_WB_S_BOM1 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP OBOM_WB_S_BOM1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OBOM_WB_S_BOM1. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the OBOM_WB_S_BOM1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_OBOM_WB_S_BOM1 TYPE STANDARD TABLE OF OBOM_WB_S_BOM1, WA_OBOM_WB_S_BOM1 TYPE OBOM_WB_S_BOM1, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <OBOM_WB_S_BOM1> TYPE OBOM_WB_S_BOM1. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_OBOM_WB_S_BOM1. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM OBOM_WB_S_BOM1 INTO TABLE IT_OBOM_WB_S_BOM1. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM OBOM_WB_S_BOM1 * INTO TABLE @DATA(IT_OBOM_WB_S_BOM12). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_OBOM_WB_S_BOM1 INDEX 1 INTO DATA(WA_OBOM_WB_S_BOM12). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_OBOM_WB_S_BOM1 ASSIGNING <OBOM_WB_S_BOM1>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<OBOM_WB_S_BOM1>-ITEM_CATEG = 1.
<OBOM_WB_S_BOM1>-COMPONENT = 1.
<OBOM_WB_S_BOM1>-COMP_QTY = 1.
<OBOM_WB_S_BOM1>-COMP_UNIT = 1.
<OBOM_WB_S_BOM1>-ITEM_TEXT1 = 1.
ENDLOOP. LOOP AT IT_OBOM_WB_S_BOM1 INTO WA_OBOM_WB_S_BOM1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_OBOM_WB_S_BOM1-ITEM_NO, sy-vline,
WA_OBOM_WB_S_BOM1-DOCUMENT, sy-vline,
WA_OBOM_WB_S_BOM1-DOC_TYPE, sy-vline,
WA_OBOM_WB_S_BOM1-DOC_PART, sy-vline,
WA_OBOM_WB_S_BOM1-DOC_VERS, sy-vline,
WA_OBOM_WB_S_BOM1-VSI_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OBOM_WB_S_BOM1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OBOM_WB_S_BOM1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OBOM_WB_S_BOM1 INTO WA_OBOM_WB_S_BOM1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field COMPONENT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OBOM_WB_S_BOM1-COMPONENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBOM_WB_S_BOM1-COMPONENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field COMP_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OBOM_WB_S_BOM1-COMP_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBOM_WB_S_BOM1-COMP_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field ITEM_NO CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_OBOM_WB_S_BOM1-ITEM_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBOM_WB_S_BOM1-ITEM_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OBOM_WB_S_BOM1-DOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBOM_WB_S_BOM1-DOCUMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VSI_SZUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_OBOM_WB_S_BOM1-VSI_SZUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBOM_WB_S_BOM1-VSI_SZUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OBOM_WB_S_BOM1_STR,
ITEM_CATEG TYPE STRING,
COMPONENT TYPE STRING,
COMP_QTY TYPE STRING,
COMP_UNIT TYPE STRING,
ITEM_TEXT1 TYPE STRING,
ITEM_NO TYPE STRING,
DOCUMENT TYPE STRING,
DOC_TYPE TYPE STRING,
DOC_PART TYPE STRING,
DOC_VERS TYPE STRING,
VSI_NO TYPE STRING,
VSI_SIZE1 TYPE STRING,
VSI_SIZE2 TYPE STRING,
VSI_SIZE3 TYPE STRING,
VSI_SZUNIT TYPE STRING,
VSI_FORMUL TYPE STRING,END OF T_EKKO_STR. DATA: WA_OBOM_WB_S_BOM1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OBOM_WB_S_BOM1_STR-ITEM_CATEG sy-vline
WA_OBOM_WB_S_BOM1_STR-COMPONENT sy-vline
WA_OBOM_WB_S_BOM1_STR-COMP_QTY sy-vline
WA_OBOM_WB_S_BOM1_STR-COMP_UNIT sy-vline
WA_OBOM_WB_S_BOM1_STR-ITEM_TEXT1 sy-vline
WA_OBOM_WB_S_BOM1_STR-ITEM_NO sy-vline
WA_OBOM_WB_S_BOM1_STR-DOCUMENT sy-vline
WA_OBOM_WB_S_BOM1_STR-DOC_TYPE sy-vline
WA_OBOM_WB_S_BOM1_STR-DOC_PART sy-vline
WA_OBOM_WB_S_BOM1_STR-DOC_VERS sy-vline
WA_OBOM_WB_S_BOM1_STR-VSI_NO sy-vline
WA_OBOM_WB_S_BOM1_STR-VSI_SIZE1 sy-vline
WA_OBOM_WB_S_BOM1_STR-VSI_SIZE2 sy-vline
WA_OBOM_WB_S_BOM1_STR-VSI_SIZE3 sy-vline
WA_OBOM_WB_S_BOM1_STR-VSI_SZUNIT sy-vline
WA_OBOM_WB_S_BOM1_STR-VSI_FORMUL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.